A Fast and Robust GC/MS/MS Analysis of 203 Pesticides in 10 Minutes in Spinach

收藏
检测样品: 小麦粉
检测项目: 理化分析
浏览次数: 26
发布时间: 2024-02-26
关联设备: 1种 查看全部
获取电话
留言咨询
方案下载

安捷伦科技(中国)有限公司

钻石23年

解决方案总数: 3278 方案总浏览次数:
方案详情
Abstract This application note describes two approaches for achieving robust, multiresidue pesticide analysis in 10 minutes by GC/MS/MS, while maintaining sufficient chromatographic resolution for the analysis of over 200 pesticides in spinach; a challenging high chlorophyll, fresh matrix. First, the conventional 15 × 15 m (0.25 mm × 0.25 μm) midcolumn backflush configuration was used with an accelerated oven ramp, yielding an analysis time of 10 minutes. Second, a minibore 10 × 10 m (0.18 mm × 0.18 μm) midcolumn backflush configuration was used, enabling a fast 10-minute analysis time. The latter method was precisely scaled using the Agilent GC method translation technique. It was shown that midcolumn backflushing enabled method robustness and extended maintenance-free operation of the system by minimizing column trimming and source cleaning. Results demonstrate that the Agilent 7000E and 7010C triple quadrupole GC/MS systems delivered excellent linearity over a concentration range of 0.1 to 1,000 parts per billion (ppb). Method robustness was shown with 700 consecutive injections of a spinach extract, spiked with pesticides at 20 ppb, that spanned over 175 hours of continuous running of the GC/TQ.

方案详情

IntroductionThere is a growing demand for more rapid methods for the identification and quantitation of chemical residues in food analysis without sacrificing method robustness and chromatographic performance. Conventional methods for multiresidue pesticide analysis typically take at least 20 minutes, resulting in longer sample cycle times. As a result, the GC/MS analysis time for a batch of samples could easily span over several days. This causes a sample analysis bottleneck and limits lab productivity. Therefore, shortening the GC/MS analysis time will undoubtedly improve sample analysis throughput and eventually laboratory productivity. However, shortened GC methods usually involve trade-offs in method robustness or performance. This application note focuses on demonstrating two fast GC/MS/MS methods using (a) the Agilent 8890 GC and 7000E triple quadrupole GC/MS system and (b) the Agilent 8890 GC and 7010C triple quadrupole GC/MS system. The presented methods provide a shortened run time of 10 minutes, while maintaining robust system performance in the challenging spinach extract, without loss in sensitivity or method performance.
确定

还剩13页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

安捷伦科技(中国)有限公司为您提供《A Fast and Robust GC/MS/MS Analysis of 203 Pesticides in 10 Minutes in Spinach》,该方案主要用于小麦粉中理化分析检测,参考标准--,《A Fast and Robust GC/MS/MS Analysis of 203 Pesticides in 10 Minutes in Spinach》用到的仪器有Agilent 7000E 三重四极杆气质联用系统