环境水中有机污染物检测方案

收藏
检测样品: 环境水(除海水)
检测项目: 有机污染物
浏览次数: 729
发布时间: 2005-01-24
关联设备: 0种
获取电话
留言咨询
方案下载

北京英格海德分析技术有限公司

金牌20年

解决方案总数: 18 方案总浏览次数:
方案详情
Hiden公司的HPR40四极质谱仪系统,可以对溶解气进行准确的分析。在环保等领域有着广泛的应用。 文章介绍了对于海水有机气体的检测应用。

方案详情

Detection of Low Levels ofOrganic SpeciesAPPLICATION NOTEHiden Analytical Ltd., 420 Europa Boulevard, Warrington WA5 7UN, United KingdomTel: +44 (0) 1925 445225 Fax: +44 (0) 1925 416518Email: info@hiden.co.uk Web: HidenAnalytical.com北京办事处电话::010-68728590/1,51661720;网址: www.Hiden.cn in Seawater Detection of Low Levels ofOrganic Species in Seawater In this particular experiment, the sensitivity ofa Hiden Quadrupole Mass Spectrometer (QMS) to dimethylsulphide wasmeasured. Dimethylsulphide (DMS)- chemical formula CH,SCH,- is a naturally produced trace substance, evolved fromcertain marine microorganisms, suchas apslankton.Detection of fluctuations in the DMS concentration inseawater therefore gives important information about theabundance of these life forms. DMS is a simple chemical. It is volatile and dissolveseasily in aqueous solution. A summary of the mainpeaks of the cracking pattern from the NIST database isseen in Table 1. Mass/amu Intensity /% Ionic Species 62 99.9 CH,SCH, 47 95.4 CHS 45 40.8 CHS 46 36.1 CHS 61 33.3 CH,SCH2 35 32.2 SH 27 20.7 CHCH Table 1: Summary ofcracking pattern for DMS. Research carried out by Philippe D. Tortell of the Dept.of Botany at the University of British Columbia,Canada, has shown that very low levels of detection canbe achieved using a quadrupole mass spectrometer. Toconduct these experiments, a Hiden HPR-40 QMSsystem was used. The system is specifically designed forthe detection1 of volatile species (such asDMS)dissolved in aqueous sample media.Other analysisapplication areas include soil analysis, fermentationcultures and water quality monitoring. The HPR-40 semi-permeable membrane inlet allowsdissolved species to be analysed, whilst preventing thebulk liquid to enter the QMS vacuum chamber. The membrane inlet permeability to volatile organicspecies, compared to non-volatile inorganic species,enhances the systems detection capability for volatileorganic species including DMS. In the University of Columbia experiment, successivedilution was used to reduce the concentration of DMS in thesample. The strongest peak at mass 62 amu was used tomeasure the concentration of DMS. Figure 1: Plot of 62 amu Partial Pressure versus ppbconcentration of DMS in seawater. As can be seen in Figure 1, the linear relationship gives ahigh degree of confidence regarding the detection levels.Further experiments could extend this detection level downto lower partial pressures. The detection limit of thespectrometer is 2 x 10-14Torr. Figure 2 the data points in the parts per billion (ppb) range,illustrate remarkable linearity. Figure 2: Plot of62 amu Partial Pressure versus lowerppb concentration ofDMS in seawater.
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

北京英格海德分析技术有限公司为您提供《环境水中有机污染物检测方案 》,该方案主要用于环境水(除海水)中有机污染物检测,参考标准--,《环境水中有机污染物检测方案 》用到的仪器有