Development and Validation of a Quantitative Method for Multiresidue Pesticides in Food Matrices Using the Agilent 6475 LC/TQ System

收藏
检测样品: 饲料
检测项目: 重金属
浏览次数: 71
发布时间: 2023-08-15
关联设备: 1种 查看全部
获取电话
留言咨询
方案下载

安捷伦科技(中国)有限公司

钻石23年

解决方案总数: 3279 方案总浏览次数:
方案详情 产品配置单
Pesticide residues remaining in or on commodities raise concerns for food safety and environmental impact. Regulatory agencies have published policy statements to guide agricultural organizations on the proper use of pesticides and established Maximum Residue Limits (MRLs) of pesticides in various food matrices. Thus, there are widely demands for highly sensitive and robust platform for the quantification of pesticide residues analysis..

方案详情

A new triple quadrupole LC/MS system, 6475 LC/TQ, which contains improvements on several aspects :• Scheduled autotune and early maintenance feedback• Enhanced software for method optimization• Intelligent reflex – new feature which enables reflexive reinjection logic• Supporting Title 21 CFR Part 11 and Annex 11 complianceAn LC-MS/MS screening method for the quantification of 497 pesticides in food matrices was developed using the 1290 Infinity II Bio LC system coupled to6475 LC/TQ. The LC/MS parameters were optimized with the new intelligent software to expand targeted pesticide list and optimize ion source. This methodwas validated in three food matrices, including wheat, olive oil and black tea. Results show excellent sensitivity, precision, accuracy and robustness on thisnew LC/TQ system.AgilentTrusted Answers Introduction Poster Reprint ASMS 2022Poster number ThP148 LinfengWu1, Aimei Zou2 1Agilent Technologies, Santa Clara, CA; 2Agilent Technologies, Singapore, Singapore Pesticide residues remaining in or on commodities raise concerns for food safety and environmental impact. Regulatory agencies have published policy statements to guide agricultural organizations on the proper use of pesticides and established Maximum Residue Limits (MRLs) of pesticides in various food matrices. Thus, there are widely demands for highly sensitive and robust platform for the quantification of pesticide residues analysis.. A new triple quadrupole LC/MS system, 6475 LC/TQ, which contains improvements on several aspects (Figure 1): • Scheduled autotune and early maintenance feedback • Enhanced software for method optimization • Intelligent reflex – new feature which enables reflexive reinjection logic • Supporting Title 21 CFR Part 11 and Annex 11compliance An LC-MS/MS screening method for the quantification of 497 pesticides in food matrices was developed using the 1290 Infinity II Bio LC system coupled to 6475 LC/TQ. The LC/MS parameters were optimized with the new intelligent software to expand targeted pesticide list and optimize ion source. This method was validated in three food matrices, including wheat, olive oil and black tea. Results show excellent sensitivity, precision, accuracy and robustness on this new LC/TQ system. Experimental Standards and sample preparation All Pesticide standards were purchased from Agilent or AccuStandard. Organic wheat, olive oil and black tea were purchased from local grocery store. Food extracts were prepared following QuEChERS EN methods. A pesticide mix comprising 497 pesticide standards was prepared and spiked into solvent and food extracts to make matrix-matched standard curves with concentration ranging from 0.1 to 50μg/L. After considering dilution factor during sample preparation, this concentration levels matches to 0.5to 250 μg/kg for wheat and black tea, and 0.2 to 100μg/kg for olive oil. All the samples were analyzed with a dynamic MRM (dMRM)-based LC-MS/MS method using MassHunter Workstation for LC/TQ 12.0 (Table 1 & 2). Instrumentation • 1290 Bio High-Speed Pump (G7132A) • 1290 Bio Multisamplerwith Cooler (G7137A) • 1290 Multicolumn Thermostat (G7116B) • 6475 Triple Quadrupole LC/MS (G6475A) with AJS source 1290 Infinity II Bio LC System Column Agilent ZORBAX RRHD Eclipse Plus C18, 2.1 × 150 mm, 1.8 μm (p/n 959759-902) Sampler temp. 4 °C Mobile phase A) 5 mM ammonium formate + 0.1% formic acid in waterB) 5 mM ammonium formate + 0.1% formic acid in Flow rate methanol 0.4 mL/min Gradient Time B (%) program 0.00 5 3.00 30 17 100 20.00 100 Post time Table 1. 1290 Infinity II Bio LC Method 6475 Triple Quadrupole Mass Spectrometer Ion source Agilent Jet Stream (AJS) source Polarity Positive and Negative Gas temperature 200 °C Drying gas 11 L/min Nebulizer gas 35 psi Sheath gas 350 °C Sheath gas flow 12 L/min Capillary voltage +3500 V, -3000 V Nozzle voltage 0 ±V MS1/MS2 resolution Unit/Unit Cycle time 500 ms Total MRMs 1003 Min/Max Dwell 1.12 ms/248.28 ms Table 2. 6475 Triple Quadrupole LC/MS Method Figure 1. 6475 Triple Quadrupole LC/MS with 1290Infinity II Bio LC system LC/MS Chromatograms The targeted compound list in a multiresidue pesticide screening method developed for the previous Agilent LC/TQ instrument model (6470 LC/TQ) was imported and further expanded using the new intelligent optimizer in MassHunter Workstation for LC/TQ 12.0. • MRMs library optimized on a previous Agilent LC/TQ models (e.g., 6470 LC/TQ) can be directly used on 6475 LC/TQ1 • New compounds were easily added using the new intelligent optimizer software2,3 • The final method resulting into monitoring 1003MRMs within 20-minutes LC gradient (Figure 2), which shows good chromatogram separation and greatly improves lab productivity Figure 2. Overlaid MRM chromatograms of all the 497pesticides post spiked at 1 µg/L inwheatmatrix extract. Quantification sensitivity with comprehensive dMRMmethod Figure 3 shows the overview of the dMRMacquisition method. The retention time window from 12 to 14 minutes contains the most concurrent MRMs with <2 ms average dwell time per MRM. Method performance for a total of 497 pesticides was evaluated in wheat, olive oil and black tea matrix extracts at 9concentration levels (Figure 4 & 5). The results were summarized as below: • Excellent linearity with 459 (92%) pesticides in wheat, 465 (94%) pesticides in olive oil and 458 (92%) pesticides in black tea showing R2 > 0.99 based on matrix-matched calibration curves. • Excellent precision and accuracy observed at all calibration levels. • Excellent sensitivity - 465 (94%) pesticides in wheat, 486 (98%) pesticides in olive oil and 466 (94%) pesticides in black tea show lower limit of quantification (LLOQ) ≤ 10 µg/kg (Figure 4) Figure 3. Overview of the comprehensive acquisition method showing user-friendly management of over 1000MRMs. Figure 4. LLOQs for the 497 pesticides in wheat, olive oil and black tea extracts. Results were classified into six relevant concentration ranges after considering dilution factor during sample preparation. Standard curves Figure 5 shows representative standard curves of four selected pesticides in black tea matrix including one early eluted analyte (Cyromazine: RT=1.25 min) and three analytes (Penconazole, Sulfotep and Penthiopyrad) with dwell time <2.0ms. Results show the 6475 LC/TQ delivers great linearity for all four analytes. Figure 5. Standard curves of four selected pesticides in black teamatrix. Robustness To test robustness of the new LC/TQ system, replicate injections (n=300) of black tea matrix spiked with pesticide standards at 10 µg/kg were performed using the comprehensive dMRM method. Outstanding reproducibility for both RT and MS signal was observed during 5-days continuous running, even for pesticides acquired with low dwell time (Figure 6). Figure 6. Response of representative pesticides in black tea extract for 300 replicate injections. Conclusions The excellent quantification performance using a new LC/TQ platform, including the Agilent 1290 Infinity II Bio LC system coupled to the 6475 Triple Quadrupole LC/MS with the Jet Stream Technology Ion Source (AJS) has been demonstrated for large panel pesticide analysis in wheat, olive oil and black tea. The platform robustness was assessed over 5 days’continuous injection using black tea extract spiked with pesticide standards, indicating the high ability of the system producing reliable result for day-to-day analysis. https://explore.agilent.com/asms References 1MP 329 High fidelity legacy-to-modern method transfer on a novel triple quadrupole LC/MS platform for large output production labs. 2MP 327 An end-to-end software algorithm for LC/MS/MS method development, optimization, and QA/QC deployment. 3WP 493 Multi-residue Method Development Using Agilent 6475 LC/TQ System Implemented with Intelligent Optimization Software: Application to Forensic Drug Screening
确定

还剩2页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

安捷伦科技(中国)有限公司为您提供《Development and Validation of a Quantitative Method for Multiresidue Pesticides in Food Matrices Using the Agilent 6475 LC/TQ System》,该方案主要用于饲料中重金属检测,参考标准--,《Development and Validation of a Quantitative Method for Multiresidue Pesticides in Food Matrices Using the Agilent 6475 LC/TQ System》用到的仪器有Agilent 6475 三重四极杆液质联用仪