汽油中烯烃含量检测方案

收藏
检测样品: 汽油
检测项目: 烯烃含量
浏览次数: 154
发布时间: 2015-09-27
关联设备: 1种 查看全部
获取电话
留言咨询
方案下载

佳士科商贸有限公司

银牌9年

解决方案总数: 276 方案总浏览次数:
方案详情
Introduction Gasoline is produced by fractional distillation of petroleum at a boiling point between 30°C and 200°C. It contains hydrocarbons such as paraffin, olefin, and aromatics, carbon numbers of which are between 4 and 10. Characterization of gasoline requires the determination of the contents of those hydrocarbons. American Society for Testing and Materials (ASTM) announced a method, D6550-00: Standard Test Method for Determination of Olefin Content of Gasolines by Supercritical-Fluid Chromatography. We have established an analysis system in accordance with this method.

方案详情

Application Note 2/3Application NoteDetermination of Olefin Content of Gasoline by Supercritical Fluid Chromatography Determination of Olefin Content of Gasoline by Supercritical FluidChromatography Gasoline is produced by fractional distillationof petroleum at a boiling point between 30℃and 200℃. It contains hydrocarbons such asparaffin, olefin, and aromatics, carbon numbersof which are between 4 and 10. Characterizationof gasoline requires the determination of thecontents of those hydrocarbons. American Society for Testing and Materials (ASTM)announced a method, D6550-00: Standard TestMethod for Determination of Olefin Content ofGasolines by Supercritical-Fluid Chromatography.We have established an analysis system inaccordance with this method. JASCO HPLC 2000 Application Library: http://www.jascoinc.com/applications Introduction A JASCO HPLC 2000 series was used for the measurement. The system consisted of a PU-2080-CO2liquefied carbon dioxide delivery pump, an AS-2059-SF autosampler, an HV-2080-01 column switchingvalve (2 sets), a CO-2060 column oven, a flame ionization detector, a BP-2080 back-pressure regulator, andChromNAV data system. Separation columns were a SFCpak SIL PA silica gel column (4.6 mm IDx250 mmL, 5 mm) and a SFCpakSIL AGS silver-coated silica gel column (4.6 mm IDx50 mmL, 5 um). The operation for the measurement was carried out as follows: 1. Connect the silica gel and silver-coated silica gel columns, and deliver liquefied carbon dioxide. 2. Inject sample to elute paraffin first. 3. Disconnect the silver-coated silica gel column from the flow path by using the column switching valves,and elute aromatics adsorbed on the silica gel column. By using the column switching valves, disconnectthe silica gel column and connect the silver-coated silica gel column again, and elute olefin adsorbed on thesilver-coated silica gel column. Results and Discussion Figure 1 illustrates a schematic of the system. Switching the two columns allowed separation of paraffin,aromatics, and olefin. Effluent from the columns was divided by a splitter and a portion of the effluent wasintroduced into the FID detector. Figure 2. SFC chromatogram ofstandard mixture. Peaks: 1=hexadecane.2=toluene, 3=octadecene.Conditions:separation column=SFCpak SIL-PA(4.6mmlDx250 mmL, 5 pm) and SFCpakSIL PA-AGS (4.6 mmlD x50 mmL,5 um),flow rate of liquefied carbon dioxide=2mL/min, injection volume=1 mL Figure 3 shows a SFC chromatogram obtained by direct injection of commercially available gasoline. Theolefin content of the gasoline was quantified to be 21.1% by comparing peak areas. Figure 3. SFC chromatogram ofcommercially available gasoline. Thechromatographic conditions are thesame as in Figure 2. JASCO INC.Mary's Court, Easton, MD USATel: ( Fax: (
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

产品配置单

佳士科商贸有限公司为您提供《汽油中烯烃含量检测方案 》,该方案主要用于汽油中烯烃含量检测,参考标准--,《汽油中烯烃含量检测方案 》用到的仪器有JASCO SFC4000超临界流体色谱仪