乙酸铜溶液中金属元素检测方案

收藏
检测样品: 其他
检测项目: 其他
浏览次数: 544
发布时间: 2015-01-16
关联设备: 0种
获取电话
留言咨询
方案下载

天津东方科捷科技有限公司

银牌12年

解决方案总数: 17 方案总浏览次数:
方案详情
1、采用专利的HDD检测器,可进行全谱采集。 2、具备恒定的高分辨率 1)2400 g/mm全息光栅:光学分辨率<5 pm(120-320 nm),<10 pm(320-800 nm); 2)4343 g/mm与2400 g/mm背靠背双光栅系统(可选):光学分辨率<6 pm(120-450 nm),<10 pm(450-800 nm)。 3、采用全球顶尖的离子刻蚀全息光栅:110×110 mm,具有极低的杂散光(1×10-7)。 4、配备CZERNY-TURNER单色仪,具备目前市面上最长的焦距(1m)。 5、采用特有的垂直矩管、侧向观测方法,可实现全等离子体观测,能够获得无可比拟的灵敏度和稳定性,尤其适用于一些复杂样品。 6、光谱范围为160-800nm,并且连续波长覆盖。

方案详情

ICP OPTICAL EMISSION SPECTROSCOPYAPPLICATION NOTE 16 Analysis of Metals in 100 g/l Copper Acetate Nathalie Le Corre Jobin Yvon S.A.S., Horiba GroupLongjumeau, France Keywords: chemicals, inorganic 1 Introduction A sample with 100 g/L Cu (CH3COO)2.H20 waspresented to this laboratory for trace determina-tion. As there was only one sample to be ana-lyzed, which had a complex matrix, the standardaddition method was used for analysis. 2 Principle 2.1 Technique used The elemental analysis of a 100 g/L Cu(CH3COO)2.H20 solution wasundertaken byInductively Coupled PlasmaOpticalEmissionSpectrometry (ICP-OES). The sample is nebulizedthen transferred to an argon plasma. It is decom-posed, atomized and ionized whereby the atomsand ions are excited. We measure the intensity ofthe light emitted when the atoms or ions returnto lower levels of energy. Each element emitslight at characteristic wavelengthsand theselines can be used for quantitative analysis after acalibration. 2.2Wavelength choice The choice of the wavelength in a given matrixcan be made using the “profile" function, or byusing Win-IMAGE, which is rapid semi-quantita-tive analysis mode using multiple wavelengths.The principle is the same in either case: recordthe scans of analytes at low concentration, andof the matrix. By superimposing the spectra, wesee possible interferences. 2.3 Limit of detection estimation The limits of detection are calculated using thefollowing formula: With: LOD = limits of detection,k= 3 for the normal 3-sigma values,BEC= Background equivalent concentration,RSDo = relative standard deviation of the blank. To calculate the LOD, a calibration curve is con-structed using two points, 0 ppm and 5 ppm, orsome concentration where the calibration is lin-ear;this gives the BEC. The RSDo is evaluated byrunning the blank ten times. 3 Sample preparation 10g of sample was weighed and dissolved with5 mL 69% HNO3 and diluted up to 100mL withdeionized water. Two spiked samples were prepared for the stan- dard addition method.Addition 1:0.1 mL of standard"A"with 25 mLof dissolved Cu (CH3COO)2.H20.Addition 2: 0.2 mL of standard"A" with 25 mL of dissolved Cu (CH3COO)2.H20. Standard "A" contained:1 g/L of Na,0.5 g/L of Ca,0.2 g/L of S, Fe, Ni, K. The concentrations of the spiked samples are list-ed in Table 1 below. Table 1: Standard addition concentration Element Concentration of Wavelength Unknown Addition1 Addition2 sample Ca 315.885 X+2 X+4 Fe 259.940 X X+0.8 X+1.6 K 766.490 X X+0.8 X +1.6 Na 589.592 X X+4 X+8 Ni 231.604 X X+0.8 x+1.6 S 182.568 X+0.8 X+1.6 4 Instrument specification The work was done on a JY ULTIMA.The specifica-tions of this instrument are listed below in Table 2and 3. Table 2: Specification of spectrometer Parameters Specifications Mounting Czerny Turner Focal length 1m Nitrogen purge Yes Variable resolution Yes Grating number of grooves 2400 gr/mm Order 2nd order Table 3: Specification of RF Generator Parameters Specifications Type of generator Solid state Observation Radial Frequency 40.68 MHz Control of gas flowrate by computer Control of pump flow by computer Cooling air 5 Operating conditions The operating conditions are listed in Table 4 below. Table 4: Operating conditions Parameter Condition RF Generator power 1200 W Plasma gas flowrate 12 L/min Auxiliary gas flowrate O L/min Sheath gas flowrate 0.2 L/min Nebulizer gas flowrate 0.8 L/min Nebulizer flowrate 3 bars (45 psi) Sample uptake 1 mL/min Type of nebulizer Parallel Type of spray chamber Cyclonic Argon humidifier No Injector tube diameter 3.0 mm 6 Wavelength selection and analyti-cal conditions For each element, the line with the highest sensi-tivity was used for analysis, because there were noproblems with interferences. The analysis condi-tions were the same for all elements except thealkali elements. Table 5: Analytical conditions Element Slits Analysis Integration (um) mode time (sec) All elements 20x15 Direct peaking 8 K 20x 80 Gaussian 0.5 The use of the parallel nebulizer and the large inter-nal diameter (ID) of the injector tube enabled trou-ble free analysis, even with the high dissolved salts.The larger the ID injector tube also ensures a mini-mization of the interferences. Due to the high dis-solved salts, an initial conditioning of the spraychamber is advised for maximum stability. It is alsoimperative to use matched standards or standardaddition because of the viscosity of solutions withhigh dissolved solids. 7 Discussion 7.1 Limits of Detection The limits of detection were calculated using theformula in paragraph 2.3. They were calculated inug/kg in the solid sample. Table 6: Limits of detection Elements LOD (ug/kg) Ca 40 Fe 5 K 90 Na 60 Ni 15 SO4 90 7.2 Determination of the unknown sample 8 Summary Using the two spiked samples and the unknown, acalibration curve was constructed. The concentra-tions of the traces in the unknown are given by theintercept of their calibration curves. The results forunknown are given in Table 7 below. Table 7: Results Element Concentration Concentration in % Expected in mg/ Value in% Ca 0.876 0.0008 <0.005 Fe 0.492 0.0005 <0.002 K 0.018 <0.00002 <0.01 Na 3.28 0.0033 <0.05 Ni 0.013 < 0.00002 <0.01 SO4 0.765 0.0008 < 0.01 To achieve the lowest detection limits, dilution isundesirable. The results show the JY spectrometersare able to perform an excellent analysis, even withhigh dissolved solids.. This enables the analysis tobe performed to the best detection limits possible. CE In the USA:Jobin Yvon Inc.3880 Park AvenueEdison, NJ 08820Tel: 1-732-494-8660Fax: 1-732-494-8796E-mail:emission@jyhoriba.com MISSION·FLUORESCENCE·FORENSICS·GRAIINGSGOEM·RAMAN·OPTICAL SPECTROSCOPY·THIN FILM
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

天津东方科捷科技有限公司为您提供《乙酸铜溶液中金属元素检测方案 》,该方案主要用于其他中其他检测,参考标准--,《乙酸铜溶液中金属元素检测方案 》用到的仪器有