Nanotechnology and Biotechnology Particel Size

收藏
检测样品: 其他
检测项目: --
浏览次数: 2830
发布时间: 2004-11-24
关联设备: 0种
获取电话
留言咨询
方案下载

大昌华嘉科学仪器

钻石24年

解决方案总数: 422 方案总浏览次数:
方案详情
Nanotechnology and Biotechnology Particel Size. Measurement Solutions, High Speed and High Efficiency Dynamic Light Scattering.

方案详情

The Nanotrac by Microtrac, Inc. Nanotechnology and Biotechnology Particle Size Measurement Solutions High Speed and High Efficiency Dynamic Light Scattering You can now measure particle size distribution in the nanometer and colloidal ranges, without the dilution required byother systems. Microtrac, Inc. has been a pioneer in light scattering particle size technology for 30 years, and introducedthe Ultrafine Particle Analyzer in 1990. The newly enhanced and designed Nanotrac, features faster measurements (up to20 times faster), smaller particle size capability (to 0.8 nm), higher precision, higher accuracy and advanced softwarecapabilities all in one small, robust dynamic light scattering instrument having no moving components. Rapid analysis - as fast as 15-30 seconds in most cases Design - No moving parts and simple design means that that there are no parts to wear nor be replaced Chemical compatibility - Compatible with all organic solvents ● ISO 13320 - Complies with this ISO standard on particle size measurements for Dynamic Light Scattering Brownian motion analysis -Advanced power spectrum analysis of Doppler shifts by the Controlled ReferenceMethod, patented by Microtrac, Inc. Temperature control-Precise temperature monitoring and compensation eliminates need for temperature controlbaths or devices High concentrations - This capability can eliminate concern of dilution, a cause of agglomeration or dissolution Low concentrations -As low as 0.1 ppm @200nm polystyrene Operation simplicity -No advance knowledge of particle distribution required- just add sample and measure Security - Software compatible with FDA 21 CFR Part 11 for computer and software security Colored materials - Avoids multiple wavelength absorption issues Physical size -Smallest dynamic light scattering footprint available in particle size industry. Also available in aremote probe model for external (“Dip‘N’Run”) measurement or for in-line measurement Accuracy-Mie scattering calculations for spherical particles and proprietary modified Mie calculations for non-spherical particles. Only Microtrac offers this enhanced accuracy for non-spherical particles - the majority of realworld materials Range-Measurement capability from 0.0008 to 6.5 microns satisfies most nanotechnology applications Calibration- First principle optical physics avoids the need for calibration-verification test kits are available.Alignment is never needed FDA Validation- Full documentation and personal customer supportSSmall sample size -Less than 3 ml per sample standard cell, or as small as 0.1 ml with small cell optionTraceability- Particle size measurement traceable to NIST standardsCCost effective long term operation- The probe design avoids cost of expendable cuvettes and pre-cleaningrequirements; A background measurement avoids need for ultra clean diluents ● Applications -Organic polymers (latex polymers and others), nanometals and other nanoinorganics, proteins,lipoproteins, DNA, and RNA Data presentation - Accurately report narrow, monomodal, multimodal, and broad range distributions in a variety ofstatistical formats without the need to select special calculation algorithms Resolution -Measures monomodal, multimodal, broad and narrow distributions automatically without pre-selectingspecial programs Consistency-Features a fixed-in-place detector and laser design, which delivers repeatability and linearity. Highconcentration capability avoids agglomeration or dissolution of particles during dilution e Flexibility - The modular design allows selectable configurations based on your application and can be expanded tomeet future needs at any time Electronics - Advanced, high efficiency electronics for accurate particle size measurements Upgrades - Prior UPA models can be upgraded depending upon present hardware and software Power demand and safety -Low power laser provides electric and laser irradiation safety Versatility- Versions for the lab bench, on-line or even in-line for process control applications Reliability -Robust, rugged design assures reliable use for many years into the future. State-of-the-art Technology The Nanotrac uses a newer, advanced power spectrum analysis of Doppler shifts to produce a full spectrum of particlesizes provided as a particle size distribution of volume (mass)percent and intensity. While other systems measure the lightafter it has passed through a sample, and at one or more angles, the Nanotrac uses a reference beam to penetrate the samplevery slightly. Light undergoing frequency shifts is collected at a shallow depth to avoid multiple scattering effects.Scattered light caused by interaction with randomly moving particles is mixed with a portion of the original laser afterbeing reflected back into the probe at 180 degrees. The combined light passes through a fiber-optic cable to a singledetector, and advanced electronics and software analyze the signals to calculate the Doppler shifts corresponding to particlesize. Controlled Reference Method technology, in which mixing of the laser and scattered light occur, provides high signalsusing low power. Small size semiconductor lasers provide extremely long life and safety. No moving parts and nomaintenance assure that the Nanotrac will reliably provide data for years without concern for repeat service visits.Advanced calculations avoid the ambiguity of polydispersity (PDI) index while providing measured distribution shape. Condensed Nanotrac Specifications Range and Spec: 0.8 to 6500 nanometers (0.0008 to 6.5 microns)Repeatability: 1% for 100nm polystyreneOptics/Alignment: Fixed laser and detector positions; 780 nm semiconductor laser directed to sample through afiber optic cable. Alignment of optics never neededMeasurement Angle: 180 degreesComplete System: Solid-state optical bench, Pentium IV computer, CRT or flat screen monitor, complete datamanagement software,printer optionsData Handling: Advanced Microtrac FLEX Software offers unparalleled capability for graphics, dataexport/import, customized printed reports, and all data handling demands including export toAdobe PDF, as well as other export formats for sharing data over the internet. FLEX softwareprovides data storage in Microsoft Access database format utilizing OLE. Volume, number,area and intensity weighted distributions as well as percentile and other summary data. Dataintegrity is ensured using FDA 21CFR Part 11 compliant security features.Sample Handling: Powders, fluids and all particles suspended or suspendable in fluid. Manual transfer andrinsing of sample for Nanotrac 150. Sample size -Less than 3 ml or as low as 0.1ml withsmall cell option. Samples may be measured by dipping probe directly into sample usingNanotrac 250. Also, automated sample handling and sample changing using the UAC 112Suspending medium: Compatible with any organic solvent and most acids and bases generally used to deliverparticulate samplesPower Requirements: 90 to 240 VAC, 5 amps, 47/63 Hz, single phaseDimensions: Height: 13 in.(33.0cm); Width: 22 in. (55.9 cm); Depth: 12 in. (30.5 cm)not including computer or UAC 112Typical Analysis time: 30 to 120 secondsDelivery Systems: None requiredMode of operation: Independent, manual operation or fully automatic control using the UAC 112For complete information on the Microtrac Nanotrac, as well as other Microtrac products, contact Microtrac Inc.. or your local Microtrac representative. Direct to Microtrac, Inc. (727) 507-9770. Domestic Sales ext 13, International Sales ext 12. Visit the Microtrac WorldWide Web site at www.microtrac.com to learn more or to locate your local Microtrac sales representative.
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

大昌华嘉科学仪器为您提供《Nanotechnology and Biotechnology Particel Size》,该方案主要用于其他中--检测,参考标准--,《Nanotechnology and Biotechnology Particel Size》用到的仪器有