中药中理化常数检测方案

收藏
检测样品: 中药制剂
检测项目: 理化性质
浏览次数: 640
发布时间: 2009-08-03
关联设备: 2种 查看全部
获取电话
留言咨询
方案下载

赛默飞中国实验室产品事业部

白金20年

解决方案总数: 77 方案总浏览次数:
方案详情
本文章详细介绍了药膏中pH的测定,包括校准液、水样的准备,校准和测量过程,以及电极和仪表的维护等内容。

方案详情

pH ofOintmentspH ofOintments pH ofOintments Star SeriesMethod Note M-1704-E 03/05 RevB Calibration and Analysis Introduction Key Words 1. Allow all the standards and the samples to attain room temperature for precise measurements since themeasurement is temperature sensitive. 2.Calibrate the meter using the pH 7.00 buffer followed by the pH 4.01 buffer, stirring the standards ata uniform rate. ·pH·Sports creamointments The new Orion 4-Star pH/ISE meter and ROSS" Sure-Flow°pH electrode (Cat No.8172BNWP)assures drug manufacturers the most stable and fast pH measurements for testing purposes. The analgesiceffectiveness of an ointment is dependent upon its pH. Therefore pH is often used in prescribed and overthe counter topical products as a critical measurement to assure product quality and performance. 3P.lace electrode temperature probe, and stirrer into beaker with pH7.00 buffer standard such that theelectrode tip is fully immersed in the solution. The stirrer should be positioned slightly below the tipof the electrode. Press the STIRRER key on the meter to turn the stirrer on. Press the CALIBRATEkey. · pHElectrode Recommended Equipment Cat. No. 4.Wait for stable reading (1-2minutes). Enter standard value of 7.00 using the UP and DOWN arrowkeys and the DECIMAL /DIGIT key. 5. Press CALIBRATE key to accept 7.00 standard and press the STIRRER key to turn the stirrer off. 6.Rinse electrode, temperature probe, and stirrer thoroughly with deionized water. Gently remove excesssolution from the outer sleeve of the electrode by dabbing with a clean paper tissue. Do not wipe orrub the sensing element of the electrode. 7.Place the probes and stirrer into beaker with the pH 4.01 buffer standard such that the electrode tip isfully immersed in the solution. The stirrer should be positioned slightly below the tip of the electrode.Press the STIRRER key on the meter to turn the stirrer on. 8.Wait for stable reading (1-2 minutes). Enter standard of 4.01 using the UP and DOWN arrow keysand the DECIMAL/DIGIT key. 9.Press MEASURE key to accept 4.01standard and to move to the measure mode of the meter.Press theSTIRRER key to turn the stirrer off. 10. Rinse electrode temperature probe, and stirrer thoroughly with deionized water. Gently remove excesssolution from the outer sleeve of the electrode by dabbing with a clean paper tissue. Do not wipe orrub the sensing element. pH of Orntments Application Package (includes all items with a Cat. No.) 1010156 1. 4 Star benchtop pH/ISE meter 1115000 2. RFOSS Sure-FlowpH electrode 8172BNWP 3. ATC probe 927007MD 4. Orion benchtop stirrer (or magnetic stir plate and bar) 096019 5. Orion benchtop electrode stand 1110001 6. Software 21CFR Part 11 1010007 7. Beakers (50 mL) 8. Graduated cylinders (50 mL) Required Solutions Cat. No. 1. pH 4.01 buffer 910104 2. pH7.00 buffer 910107 3. pH 10.01 buffer 910110 4. Reference Filling Solution 810007 11. Place the probes and stirrer into prepared sample such that the electrode tip is fully immersed in thesolution. Press the MEASURE key on the meter; the stirrer will turn on. The pH icon will flash as themeasurement is being made. The pH icon will become solid and the display value will freeze when astable reading is achieved. This value is logged, printed and the stirrer turns off automatically. 5. Electrode Storage Solution 910001 6.Deionized water. Remember rinse electrodes with deionized water between measurements. Upon completion ofsamples, rinse the electrode with deionized water and store the electrode according to instructions inthe “Storage"section of this method note. Calibration Standard Preparation 1 Using a graduated cylinder, transfer 30 mL of the pH 7.00 buffer into a 50 mL beaker. Repeat steps 10 and 11 for additional samples. 2. Using a graduated cylinder, transfer 30 mL of the pH 4.01 buffer into a 50 mL beaker. If the sample is so thick that stirring is not possible, the sample should be gently agitated with the electrodeto speed electrode response. Remember to rinse the electrode with deionized water between measurements.Upon completion of the samples, rinse electrode with deionized water and store the electrode according tothe instructions in the “Storage"section of this method note. Sample Preparation 1 Squeeze 30 mL of the sample out of the ointment tube, into a 50 mL beaker. 2 Repeat this procedure for additional measurements. Results Five samples are measured and the results provide a representative results expected for pH in ointments. ( Environmental Instruments Water Analysis Instruments ) ( 1 66 Cummings C enterBeverly, MA 01915 USA M - 1 7 04 - E 03/05 Re vB 2 48117-001 ) Toll Free: 1-800-225-1480Tel:1-978-232-6000Dom. Fax:1-978-232-6015Intl Fax:978-232-6031www.thermo.com/waterO 2005 Thermo Electron Corporation RegisteredIS O9001:2000 All rights reserved Ointments pH S a m p l e # 1 : 5.98 Sample # 2: 5.97 Sample #3: 5.98 Sample #4: 5.97 Sa m p le #5 : 5 .9 7 Mean: 5.97 Standard Deviation: 0.01 %CV: 0.09 Electrode Storage To ensure a quick response and free-flowing liquid junction, the sensing element and reference junction mustremain wet and not be allowed to dry out. For short-term storage (up to one week), soak electrode in Orion pHelectrode storage solution. If not available, as a temporary substitute, use about 200 mL of Orion pH 7 bufferwith 1 gm KCl added. For prolonged storage, the reference chamber should be filled with the fill hole cover in place. Cover thesensing element and reference junction with the protective cap containing a few drops of pH storage solution.After prolonged storage, prepare the electrode as described in the Electrode Setup section of this method. Equipment Setup Electrode Setup 1. Remove the protective shipping cap from sensing element and save cap for storage. 2.Clean any salt deposits from exterior by rinsing with deionized water. 3 Uncover filling hole by removing plastic sleeve and add ROSS internal filling solution. To maintain anadequate flow rate, the level of filling solution must cover the end of the coil and be at least one inch abovethe sample level when immersed. The filling hole should be open whenever the electrode is in use. 4. Shake down the electrode to remove air bubbles. Meter setup-4 Star benchtop For initial meter setup, follow the steps on the Reference Panel that is attached to the meter itself. The QuickStart Guide also contains a layout of the meter keypad for reference. The words in this method represented inall capital letters, such as POWER, indicate a key on the meter, and words in quotations such as “Unit"indicateinformation on the meter display. 1.Connect the electrode to the meter. 2. Connect the temperature probe to the meter.3C.onnect the stirrer to the printer. 4.Press the POWER key on the meter to turn the meter on. 5.Note that the arrow on the left of the screen indicates the active line. If not the top line is not active, pressthe LINE SELECTION key to change the selected line to the top line. Then press the UP or DOWNarrow keys to change the measurement mode of the top line to pH. 6.Press the SETUP key to enter pH Setup. Press the LINE SELECTION key to select the middle line.Press the UP or DOWN arrow keys to select "rES” which is resolution. 7.Press the LINE SELECTION key to select the bottom line. Press the UP or DOWN arrow keys to select“0.01” for“rES” which is an abbreviation for resolution or number of significant digits. Press the LINESELECTION key to accept value. 8.Press the LINE SELECTION key to select the middle line, and press the UP or DOWN arrow key toselect “bUF”which is pH buffer. 9.Press the LINE SELECTION key to select the bottom line, and press the UP or DOWN arrow key toselect“USA”which is US/Orion buffers. 11. Press the MEASURE key to return to the measurement mode. 10. Press the LINE SELECTION key to accept and select the pH Setup Menu line (Top Line). If all steps were followed correctly the meter display will show three digits in the top line and“ISE: mg/L"to the right of the top line. The meter and electrode are now ready for calibration. Note: The Orion Benchtop Stirrer must be turned on in General Instrument setup before analysis,please see the Quickstart guide for instructions. www.thermo.com off of of
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

赛默飞中国实验室产品事业部为您提供《中药中理化常数检测方案 》,该方案主要用于中药制剂中理化性质检测,参考标准--,《中药中理化常数检测方案 》用到的仪器有台式pH/ORP/ISE/溶解氧/电导率测量仪、Orion 4-Star系列台式(便携式)pH/离子浓度,pH/电导率,pH/溶解氧测量仪