土壤中P元素检测方案(等离子体质谱)

收藏
检测样品: 土壤
检测项目: 营养盐
浏览次数: 266
发布时间: 2017-12-20
关联设备: 0种
获取电话
留言咨询
方案下载

安捷伦科技(中国)有限公司

钻石23年

解决方案总数: 3278 方案总浏览次数:
方案详情
Quadrupole ICP-MS (ICP-QMS) is one of the most widely used analytical techniques in inorganic testing laboratories, due to its performance characteristics of high sensitivity, low detection limits, wide dynamic range, and high speed multi-element analysis.

方案详情

Routine soil analysis using an Agilent8800 ICP-QQQ Introduction: Quadrupole ICP-MS (ICP-QMS) is one of the most widely used analytical techniques in inorganic testing laboratories,due to its performance characteristics of high sensitivity, low detection limits, wide dynamic range, and high speedmulti-element analysis. Recent advances have seen a dramatic improvement in matrix tolerance: Agilent’s High Matrix Introduction (HMI)technology uses aerosol dilution to reduce the sample matrix load on the plasma, ensuring that much higher matrixlevels-up to % levels of total dissolved solids (TDS)-can be analyzed routinely. Control of interferences has also been improved significantly, with Agilent's octopole-based collision/reaction cell(CRC) operating in helium (He) collision mode to eliminate a wide range of matrix based polyatomic interferencesusing one set of cell conditions [1]. Reliable and accurate quantitation of all required elements at the regulatedlevels in a wide variety of sample matrices is now possible using ICP-QMS. However, some applications requiregreater sensitivity for some specific elements, while some complex sample matrices may cause spectralinterferences that remain a challenge. Agilent Technologies Quadrupole ICP-MS (ICP-QMS) is one of the most widely used analytical techniques in inorganic testing laboratories, due to its performance characteristics of high sensitivity, low detection limits, wide dynamic range, and high speed multi-element analysis.Recent advances have seen a dramatic improvement in matrix tolerance: Agilent’s High Matrix Introduction (HMI) technology uses aerosol dilution to reduce the sample matrix load on the plasma, ensuring that much higher matrix levels—up to % levels of total dissolved solids (TDS)—can be analyzed routinely.Control of interferences has also been improved significantly, with Agilent’s octopole-based collision/reaction cell (CRC) operating in helium (He) collision mode to eliminate a wide range of matrix based polyatomic interferences using one set of cell conditions [1]. Reliable and accurate quantitation of all required elements at the regulated levels in a wide variety of sample matrices is now possible using ICP-QMS. However, some applications require greater sensitivity for some specific elements, while some complex sample matrices may cause spectral interferences that remain a challenge.
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

安捷伦科技(中国)有限公司为您提供《土壤中P元素检测方案(等离子体质谱)》,该方案主要用于土壤中营养盐检测,参考标准--,《土壤中P元素检测方案(等离子体质谱)》用到的仪器有