药包材中萃取物和浸出物检测方案(液相色谱仪)

收藏
检测样品: 其他
检测项目: 溶出物
浏览次数: 290
发布时间: 2016-11-30
关联设备: 1种 查看全部
获取电话
留言咨询
方案下载

安捷伦科技(中国)有限公司

钻石23年

解决方案总数: 3278 方案总浏览次数:
方案详情
Quadrupole time-of-flight (Q-TOF) mass spectrometers are suitable for this purpose due to their high resolution and accurate mass measurement capabilities. An Agilent 1290 Infinity LC System and an Agilent 6540 Q-TOF system combined with statistical analysis software were used to detect and identify extractable and leachable (E&L) impurities from ophthalmic drug products.

方案详情

.Agilent Technologies Extractables and Leachables Detected inOphthalmic Drug Products 摘要: Compounds leaching from container closure systems can cause contamination to drug substances orproducts. As part of a risk evaluation, it is necessary to identify these compounds and ensure that thedrugs are suitable for their intended use. Typically, such compounds are present at low concentrationsand are masked by the drug matrix. Therefore, highly sensitive and selective methods are required todetect and identify these compounds. Quadrupole time-of-flight (Q-TOF) mass spectrometers aresuitable for this purpose due to their high resolution and accurate mass measurement capabilities.An Agilent 1290 Infinity LC System and an Agilent 6540 Q-TOF system combined with statisticalanalysis software were used to detect and identify extractable and leachable (E&L) impurities fromophthalmic drug products. Statistical data analysis was performed using Agilent Mass ProfilerSoftware (MP) to determine the compounds present in the samples compared to controls. Thedatabase search tool within MP software helped to identify E&Ls using a customized accurate massdatabase. For the identification of unknown E&Ls, MS/MS data together with the structure predictionsoftware, Molecular Structural Correlator, was used. In this study, 50 compounds were detected ineach of the E&L samples. Compounds leaching from container closure systems can cause contamination to drug substances or products. As part of a risk evaluation, it is necessary to identify these compounds and ensure that the drugs are suitable for their intended use. Typically, such compounds are present at low concentrations and are masked by the drug matrix. Therefore, highly sensitive and selective methods are required to detect and identify these compounds. Quadrupole time-of-flight (Q-TOF) mass spectrometers are suitable for this purpose due to their high resolution and accurate mass measurement capabilities. An Agilent 1290 Infinity LC System and an Agilent 6540 Q-TOF system combined with statistical analysis software were used to detect and identify extractable and leachable (E&L) impurities from ophthalmic drug products. Statistical data analysis was performed using Agilent Mass Profiler Software (MP) to determine the compounds present in the samples compared to controls. The database search tool within MP software helped to identify E&Ls using a customized accurate mass database. For the identification of unknown E&Ls, MS/MS data together with the structure prediction software, Molecular Structural Correlator, was used. In this study, 50 compounds were detected in each of the E&L samples.
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

产品配置单

安捷伦科技(中国)有限公司为您提供《药包材中萃取物和浸出物检测方案(液相色谱仪)》,该方案主要用于其他中溶出物检测,参考标准--,《药包材中萃取物和浸出物检测方案(液相色谱仪)》用到的仪器有Agilent 1290 Infinity II 液相色谱系统