A methodology using capillary electrophoresis with tandem mass spectrometry detection (CE-MS/MS) was developed, and applied to determine the cocaine content of seized drugs. The cocaine separation among other concomitants by capillary electrophoresis was achieved in just 4.0 minutes using 30 mM ammonium formate, pH 6.5, as a background electrolyte (BGE). The correlation coefficient of the calibration curve in the range of 0.02 to 1 μg/mL was upper 0.999, and the limits of detection (LOD) and limits of quantification (LOQ) were 0.003 μg/mL and 0.01 μg/mL, respectively. The relative standard deviation repeatability (intraday and interday) was less than 6.5% (peak area). The analysis of seized suspected illegal drugs revealed the presence of cocaine in 93% of samples (n = 11), in amounts ranging from 0.04 to 429 mg/g, showing a high variability of concentrations of cocaine. The user can change the provider and, due to the large variability of concentration, be lead to an accidental overdose

方案详情

Detection of Cocaine in Seized DrugSamples by Capillary ElectrophoresisTandem Mass Spectrometry Abstract: A methodology using capillary electrophoresis with tandem mass spectrometry detection(CE-MS/MS) was developed, and applied to determine the cocaine content of seized drugs.The cocaine separation among other concomitants by capillary electrophoresis wasachieved in just 4.0 minutes using 30 mM ammonium formate, pH 6.5, as a backgroundelectrolyte (BGE). The correlation coefficient of the calibration curve in the rangeof 0.02 to 1 Hg/mL was upper 0.999, and the limits of detection (LOD) and limits ofquantification (LOQ)were 0.003 Hg/mL and 0.01 Hg/mL, respectively. The relativestandard deviation repeatability (intraday and interday) was less than 6.5%(peakarea). The analysis of seized suspected illegal drugs revealed the presence of cocainein 93% of samples (n=11), in amounts ranging from 0.04 to 429 mg/g, showing a highvariability of concentrations of cocaine. The user can change the provider and, dueto the large variability of concentration,, be lead to an accidental overdose · Agilent Technologies A methodology using capillary electrophoresis with tandem mass spectrometry detection (CE-MS/MS) was developed, and applied to determine the cocaine content of seized drugs. The cocaine separation among other concomitants by capillary electrophoresis was achieved in just 4.0 minutes using 30 mM ammonium formate, pH 6.5, as a background electrolyte (BGE). The correlation coefficient of the calibration curve in the range of 0.02 to 1 μg/mL was upper 0.999, and the limits of detection (LOD) and limits of quantification (LOQ) were 0.003 μg/mL and 0.01 μg/mL, respectively. The relative standard deviation repeatability (intraday and interday) was less than 6.5% (peak area). The analysis of seized suspected illegal drugs revealed the presence of cocaine in 93% of samples (n = 11), in amounts ranging from 0.04 to 429 mg/g, showing a high variability of concentrations of cocaine. The user can change the provider and, due to the large variability of concentration, be lead to an accidental overdose
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

安捷伦科技(中国)有限公司为您提供《毒品中可卡因检测方案(毛细管电泳仪)》,该方案主要用于其他中可卡因检测,参考标准--,《毒品中可卡因检测方案(毛细管电泳仪)》用到的仪器有Agilent 7100 毛细管电泳系统