库仑法卡氏水份仪测定丙酮中水分含量

收藏
检测样品: 其他
检测项目: --
浏览次数: 1920
发布时间: 2009-03-17
关联设备: 4种 查看全部
获取电话
留言咨询
方案下载
方案详情
库仑法卡氏水份仪测定丙酮中水分含量 使用日本京都电子公司(KEM)-库仑法卡氏水份测定仪(MKC-520),带无隔膜电解电极,测定丙酮中水分含量的应用资料。

方案详情

KCZ-06071Kyoto Electronics Manufacturing Co., LtdData No. LA39-06053 No.KCZ-06071 KEM Application NoteCoulometric Karl Fischer titration Moisture measurement on Acetone -Summary- As the result of the feasibility study of the moisture measurement for acetone by MKC-520, agood repeatability was observed. Therefore,this measurement is judged possible. -Measuring instrument- -Measuring instrument- Main unit:MKC-520 Coulometric KF moisture titrator Electrode: M-712 Twin Platinum Electrode #433-0048 Inner burette (one chamber) -Reagent- Anolyte: Coulomat AK -Measuring method- Preparation: (1) Put 150mL of Anolyte in the titration cell. (2) Pre-titrate it for dehydration. Measurement: (1) Take approximately 0.75g of the sample with the syringe and measure the moisture of it. -Equation- Moisture(%): ((Data-BG× t-Blank)/ (Wt1-Wt2))/10000 -Ambient conditions- Temperature:25.8°℃ Relative Humidity: 53 % Weather: Fine 京都电子工业株式会社-可睦电子(上海)商贸有限公司.上海市漕溪路222号航天大厦北楼902室电话:021-54488867 电邮: kemu-kem@163.com网址: http://www.kyoto-kem.net.cn -Measurement parameter- -Printout data- 「TITR.PARA1 Method 1 Titr. Cell No.1 t(Stir) 0s t(Wait) 0 s t(Max) 0s Drift Stop Rel 0.1 pg/s Cont.Gain 5.0 Stable 0.1 pg/min Start Auto Oven Off 「CALCU.PAR A1 Calc. No. 2 Unit : % Weight : Variable Drift Comp: Auto ** *Result*** Sample No. 01-01 Date 2006/03/0413:50Titr. Cell No.1 Wt1 0.7619 gWt2 0.0000 g Net 0.7619 g Result 1470.9 ug 0.1931 % ***Result* ** Sample No. 01-02 Date 2006/03/04 14:10 Titr. Cell No.1 Wt1 0.7966 g Wt2 0.0000 gNet 0.7966 g Result 1525.2 ug 0.1915% ***Result*** Sample No. 01-03 Date 2006/03/04 14:24 Titr. Cell No.1 Wt1 0.7401 gWt2 0.0000 g Net 0.7401 g Result 1419.6 ug 0.1918% -Measurement results- Run Sample size (g) Moisture(ug) Conc.(%) Statistics 1234 5 0.76190.79660.74010.7004 0.8232 1470.91525.21419.61340.7 1587.3 0.19310.19150.19180.19140.1928 MeanSD RSD 0.1921 %0.0008 %0.4020 % -Comments- A reagent compatible with ketone is used as Anolyte in order to deter the formation ofwater by reaction with the ketone group in the sample. For your reference, an alternativemethod to deter this side reaction is to make measurements while cooling the measuringcell. ( 京都电子工业株式会社-可睦电子(上海)商贸有限公司 电话:0 2 1-54488867 电邮: k e mu-kem@163.com ) 上海市漕溪路222号航天大厦北楼902室网址: http://www.kyoto-kem.net. cn
确定

还剩1页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

可睦电子(上海)商贸有限公司-日本京都电子(KEM)为您提供《库仑法卡氏水份仪测定丙酮中水分含量》,该方案主要用于其他中--检测,参考标准--,《库仑法卡氏水份仪测定丙酮中水分含量》用到的仪器有MKH-710M容量法库仑法混合型卡尔费休水分仪、MKC-710B卡尔费休库仑法微量水分测定仪、MKC-710S豪华型库仑法卡尔费休水分仪、MKC-710M四通道旗舰型库仑法卡尔费休水分仪