润滑油中碱值检测方案(自动电位滴定)

收藏
检测样品: 润滑油
检测项目: 理化分析
浏览次数: 382
发布时间: 2017-11-25
关联设备: 4种 查看全部
获取电话
留言咨询
方案下载
方案详情 产品配置单
全自动电位滴定仪测定润滑油的碱值 使用日本京都电子公司(KEM)-自动电位滴定仪(AT-510),测定润滑油碱值的应用资料。

方案详情

KeM Application Note No.TIA-06311PAetroleumcid-BaseproductsBase number of lubricant titration(Non-aqueous) 1. Abstract The Base Number (BN) of petroleum products and lubricants can be determinedby potentiometric titration method with 0.1mol/L Perchloric acid standard aceticacid solution according to “JIS K2501 Petroleum products and lubricants -determination of neutralization number”,“ASTM D2896 Standard Test Method forBase Number of Petroleum Products by Potentiometric Perchloric Acid Titration",“ISO 3771 Petroleum products - Determination of base number -Perchloric acidpotentiometric titration method” or the like. The end point is the inflection pointon the titration curve. In the case where inflection points are not definitive, apply the back titrationmethod with Sodium acetate standard acetic acid solution. Then calculate theBase Number (BN) of petroleum products and lubricants from the volume ofPerchloric acid standard acetic acid solution required for titration until the endpoint. The sample is usually dissolved in a mixture of Chlorobenzene and Acetic acid.Therefore, the possible basic constituents in petroleum products and lubricantsinclude organic bases, inorganic bases, amino compounds, weak acid salts(soap), and basic salts of polyacidic bases. 2. Reference 1) JIS K2501 Petroleum products and lubricants -determination of neutralizationnumber 2) ASTM D2896 Standard Test Method for Base Number of Petroleum Productsby Potentiometric Perchloric Acid Titration 3) ISO 3771 Petroleum products -Determination of base number-Perchloric acidpotentiometric titration method 上海市漕溪路222号航天大厦北楼902室网址: http://kem.instrument.com. cn 3. Tips for measurement 1) After each measurement, immerse electrodes in distilled water for a fewminutes to one hour to recover the sensitivity of them. 2) The oils containing perbasic additives or polymers having nitrogen are likely toshow rather higher test results, 3) Acetic acid, Acetic anhydride acid and Chlorobenzene are toxic and irritative.Whole operations of these chemicals shall be carried out in a well ventilatedplace or in a draft. 4) Because of the relatively large coefficient of cubic expansion of organicsolvents, the difference between temperatures of standardization and in use ofPerchloric acid standard acetic acid solution shall be within 5°C. 5):Standardize repeatedly the Perchloric acid standard acetic solution at leastonce a week. 4. Equipment Main unit : Automatic potentiometric titratorr/AT-510 Detector : Standard preamplifier STD-510 Combination glass electrode C-173 + Cable #429-0012 (Replace the inner filling of reference electrode with saturatedPerchloric acid standard acetic acid solution.) 5. Reagent Titration solution :0.1mol/L Perchloric acid standard acetic acid solutionAdditive : Acetic acid : Chlorobenzene=1 : 2 6. Analysis Procedure 1) Place 0.6g of sample in 200mL beaker. 2) Add 120mL of solvent and dissolve the sample. 3) Titrate with 0.1mol/L Perchloric acid standard acetic acid solution to determinethe total base number of lubricant. 7. Calculation Total base number (mg/g):(EP1-BL1)xTFxC1xK1/SIZE EP11 :volume(mL) BL1 : blank(mL)=0 : titrant factor=0.934c: concentration conversion coefficient=5.611 (1mL of 0.1mol/L HCIO4 corresponds to 5.611mg of Potassium hydroxide) K1 : unit conversion coefficient=1 SIZE :sample size (g) 京都电子工业株式会社-可睦电子(上海)商贸有限公司上海市市溪路222号航天大厦北楼902室电话:021-54488867 电邮: kemu-kem@163. com网址: http://kem. instrument.com.cn 8. Example of Measurement -Ambient condition- Room temperature: 22.5C Humidity: 47% 上海市漕溪路222号航天大厦北楼902室网址: http://kem. instrument. com.cn Run Size(g) Vol.(mL) Total base number(mg/g) 1 23 0.63470.63470.6363 6.05266.0222 6.0570 49.967 49.716 49.878 Statistics MeanSD RSD 49.854 mg/g0.1273 mg/g0.2553% 【AT-610】 【AT-510】 【AT-500N-1】 Awarded Supreme Technology fromKyoto City · Compact and cost performancemodel · Low cost and high performance · Easy view with back light LCD ·Easy key entry by touch panel oflarge color LCD (8-inch wide) ·PC card expands data memory forrconvenience and versatility. · GLP/GMP conformed model · Simultaneous titration in parallel · Both potentiometric and KarlFischer moisture titration(coulometric·volumetric) can beperformed at a time. K-M KYOTO ELECTRONICSMANUFACTURING CO.,LTD. Overseas Division: 8-3,Niban-cho,Chiyoda-ku,TOKYO 102-0084 JAPAN FAX:+81-3-3237-0537, Phone:+81-3-3239-7333 E-mail: export@kem.co.jp URL:http://www.kyoto-kem.com Factory: 56-2 Ninodan-cho,Shinden Kisshoin,Minami-ku,KYOTO601-8317,JAPAN FAX:+81-75-691-9961, Phone: +81-75-691-4122 E-mail: tech-english@kem.co.jp TIA-06311 4/4 京都电子工业株式会社-可睦电子(上海)商贸有限公司上海市漕溪路222号航天大厦北楼902室电话:021-54488867 电邮: kemu-kem@163.com网址: http://kem. instrument.com.cn TIA- /京都电子工业株式会社-可睦电子(上海)商贸有限公司电话: 电邮: kemu-kem@com TIA- /
确定

还剩2页未读,是否继续阅读?

不看了,直接下载
继续免费阅读全文

该文件无法预览

请直接下载查看

可睦电子(上海)商贸有限公司-日本京都电子(KEM)为您提供《润滑油中碱值检测方案(自动电位滴定)》,该方案主要用于润滑油中理化分析检测,参考标准--,《润滑油中碱值检测方案(自动电位滴定)》用到的仪器有AT-710B简易实用型自动电位滴定仪、AT-710S豪华型自动电位滴定仪、AT-710M四通道旗舰型自动电位滴定仪、石油产品自动电位滴定仪