方案详情
文
The importance of refrigerant composition analysis became clear when contami-
nated and counterfeit refrigerant 1,1,1,2-tetrafluorethane (R134a) appeared on the
market. Chloromethane (R40), present in this counterfeit R134a, is found to be
incompatible with aluminum surfaces in the refrigerant system. A chemical reaction
takes place resulting in a pyrophoric compound upon contact with air. This applica-
tion note highlights fast, on-site characterization of the refrigerant mixture using
the Agilent 490 Micro GC.
·Agilent Technologies Composition Analysis ofContaminated and CounterfeitRefrigerants Using theAgilent 490 Micro GC Abstrac: The importance of refrigerant composition analysis became clear when contami-nated and counterfeit refrigerant 1,1,1,2-tetrafluorethane (R134a) appeared on themarket. Chloromethane (R40), present in this counterfeit R134a, is found to beincompatible with aluminum surfaces in the refrigerant system. A chemical reactiontakes place resulting in a pyrophoric compound upon contact with air. This applica-tion note highlights fast, on-site characterization of the refrigerant mixture usingthe Agilent 490 Micro GC. 点击下列图标获取免费资料 Apihent Tackw
还剩1页未读,是否继续阅读?
安捷伦科技(中国)有限公司为您提供《受污染的假冒制冷剂中组分分析检测方案(便携式气相)》,该方案主要用于其他中组分分析检测,参考标准--,《受污染的假冒制冷剂中组分分析检测方案(便携式气相)》用到的仪器有Agilent 490 微型气相色谱仪