温度湿度

仪器信息网温度湿度专题为您整合温度湿度相关的最新文章,在温度湿度专题,您不仅可以免费浏览温度湿度的资讯, 同时您还可以浏览温度湿度的相关资料、解决方案,参与社区温度湿度话题讨论。
当前位置: 仪器信息网 > 行业主题 > >

温度湿度相关的耗材

  • 温度湿度控制设备恒温恒湿箱感应纱布
    温度湿度控制设备恒温恒湿箱感应纱布温度湿度控制设备感应纱布在恒温恒湿试验箱、高低温交变湿热试验箱、低温恒温恒湿试验箱、高低温湿机、潮湿试验箱、高低温湿热试验箱等带湿度的测试仪器试验设备中,都有恒温恒湿箱试验纱布,测试湿度感测湿球纱布。数量:一包10片规格:约7*9CM价格:262元/包温度湿度控制设备恒温恒湿箱感应纱布 温度湿度控制设备恒温恒湿箱感应纱布在恒温恒湿试验箱、高低温交变湿热试验箱、低温恒温恒湿试验箱、高低温湿机、潮湿试验箱、高低温湿热试验箱等带湿度的测试仪器试验设备中,都有恒温恒湿箱试验纱布,测试湿度感测湿球纱布。 感应纱布东莞市皓天试验设备有限公司专业生产/销售高低温试验箱,恒温恒湿试验箱,冷热冲击试验箱等环境设备.销售部资料各种规格的设备资料信息.
  • LM8000风速/照度/温湿度/温度计
    LM8000风速/照度/温湿度/温度计 风速/照度/温湿度/温度计LM8000的特点: &bull 首创一机四功能,风速,照度,温湿度/温度计 &bull 风速0.4~30米/秒.± 3%(温度0~50° C) &bull 湿度10.0~95.0%.± 4%(温度0~50.0° C) &bull 照度0~20000LUX.± 5%(自动换档) &bull 温度(K Type)-100.0° C~1300.0° C.± 1% &bull 读值锁定及记录测量中之最大/最小值. &bull 双窗口显示器,同时显示风速(湿度)/温度值. &bull Size:156x60x33mm
  • HC2S3温度和湿度传感器
    HC2S3是由Campbell Scientific Inc.生产的温度和湿度探头,是一种准确度高、坚实、耐用的可适用于野外长期观测的温度相对湿度传感器。  HC2S3采用了先进的电容式传感器测量相对湿度。HC2S3使用与HMP45C相同的41003-5防辐射罩,可以方便地进行更换。另外,该传感器配有一个聚乙烯过滤器,用来防止灰尘和微粒进入,保证了传感器测量的优越能和可靠性。在配备聚四氟乙烯的过滤器后,HC2S3虽在响应时间方面略有下降,但可大幅提高环境适应性,能够在海洋等高盐分、高湿度环境下正常使用。 特点:非常适合于长期,无人值守的站点;精度高,结实耐用;快速安装于三脚架或者塔上的横臂上面,也可以安装于客户的塔;HC2S3探头测量空气温湿度,建议为其配备41003-5型防辐射罩;技术参数:  温度  传感器类型:PT100热敏电阻;  温度量程:-40~60℃(标准);-45~100℃(扩展)  温度精度:±0.1℃(20℃时),±0.3℃(-40℃时);  长期稳定性:0.1℃/年  响应时间:4秒(63%时间常数,1m/s)  相对湿度  传感器类型:ROTRONIC Hygromer IN-1相对湿度探头  相对湿度量程:0~100%RH  相对湿度精度:±0.8%RH(20℃时);±3.3%RH(-40℃时)  长期稳定性:;1%RH/年  响应时间:10秒(63%时间常数,1m/s)  传感器  工作温度:-40~100℃  过滤器:聚乙烯或聚四氟乙烯  输出信号:0~1V  能耗:4.5 mA(3.3VDC时);4.3mA(5VDC时);2.0mA(12VDC)  供电:5~24 VDC  最大启动电流:50mA(2μs)  外形尺寸:15mm(直径)×168mm(长)  重量:10g 产地:美国

温度湿度相关的仪器

  • 测量原理独特的多参数传感器,有着极为紧凑和坚固的外壳,可以同时测量土壤湿度、土壤温度和土壤导电率。与其他土壤湿度传感器不同,Hydra探头通过同时测量介电常数和导电率来获得土壤湿度。介电常数和导电率对土壤湿度这一参数的影响很大:介电常数是水含量最直接的指标,而导电率也在很大程度上取决于土壤盐度。高频电气测量可以测定土壤的电容和导电性质,这两种性质与土壤湿度和盐度直接相关,同时热敏电阻可以测定土壤温度。所有这三个参数均通过SDI-12接口进行传输。小巧而精确设定的感应区域可以对土壤湿度较大的区域进行精确测量,比如靠近土壤表面的区域。传感器可对土壤湿度的变化进行快速响应,且无需标定。Hydar探头配备了一根可直接掩埋的连接电缆,能够对一大片研究区域内的各种土壤状况进行数据采集。技术指标介电常数量程精度:1至65,其中1=空气,78=蒸馏水±1.5%和±0.2中较大值土壤湿度量程精度:从完全干燥到完全饱和 一般土壤中含水量体积的±0.03导电率量程精度:±2%or±0.002dS/m, ±2%和±0.002dS/m中较大值温度范围精度:-10°C-+65°C/14°F-149°F ±0.6°C传感器体积(圆柱形)直径:3,0cm(1.2") 长度:5,7cm(2.2")工作温度:土壤中:冰冻温度至+65°C/149°F防护:可持续承受完全浸没长度:12,4cm(4.9")直径:4,2cm(1.6")重量:200g(仅探头)输出信号:SDI-12电源要求:6-30VDC,一般为20mA订购信息200.733.103 Hydra探头200.733.506 A506 SDI-12适配器
    留言咨询
  • XY-S92数字温湿度计产品介绍:XY-S92数字温湿度计是一款具有专业测量空气温度、空气湿度、露点温度、湿球温度和绝对湿度测量的功能。另外还有数据保持、自动关机、最大最小值记录等功能。产品特点:★ 小巧请便,易于操作★ 最大、最小值记录★ 空气温湿度、露点温度、湿球温度、绝对湿度测量功能★ 电量低自动提醒★ 无操作,自动关机技术参数:显示屏: 带背光液晶显示屏温度范围:-30--100℃ 分辨率:0.1℃湿度范围:0%-100%RH 分辨率:0.1%RH露点温度:-30--100℃ 分辨率:0.1℃湿球温度:0-80℃ 分辨率:0.1℃绝对湿度:0-500g/mm3响应时间:<15s操作温度:0-50℃操作湿度:<80%RH电池型号::9V 重量:400g尺寸:300x 75 x50mm
    留言咨询
  • 维萨拉DL2000温度与相对湿度数据记录仪产品介绍维萨拉2000系列数据记录仪适合针对温度、相对湿度及您所选定模拟传感器实现高精度测量。2000记录仪采用内置温度及相对湿度传感器,并可选配用千记录诸如压差、二氧化碳、电平、颗粒度和导电率等参数的电流或电压输入信号的外部通道。2000系列记录仪还可选配用千门开关或报警触点的布尔通道。2000系列数据记录仪可通过USB直接与PC计算机连接,也可通过以太网、PoE或WiFi方式安装在现有网络上,非常适合供独立或联网应用使用。每台记录仪均配备10年寿命电池和用于记录测量点各种参数的板载存储器。该记录仪由于具有自主供电和记录能力,其数据不会受到网络和电力中断影响。2000系列数据记录仪可配合软件实现环境数据下载、显示和分析功能,并可提供满足21 CFR Part 11要求的防篡改电子记录。选配基千浏览器的viewLinc系统具有全天候多级报警通知、远程实时监测功能,不存在数据中断问题。报告可自行定制,并可导出为Excel格式。维萨拉DL2000温度与相对湿度数据记录仪功能/优点&bull 业内领先的温度与相对湿度测量精度&bull 高精度、可调节基于时间的数字式记录&bull 可提供任意时间段的打印报告&bull 采用寿命长达10年的电池&bull 同一型号仪表既可验证又可用于连续监测&bull NIST可追溯、A2LA认证校准&bull 图表记录仪与硬布线系统的绝佳替代产品&bull 集成高精度相对湿度传感器维萨拉DL2000温度与相对湿度数据记录仪技术参数接口RS-232串口、USB、WiFi、以太网、PoE(vNet)PC软件软件绘图及报告:Spectrum、vLog(符合FDA/GxP规范要求)内部时钟精确度为±1分/月@-25℃~+70℃内置温度传感器工作范围:-35°C~+85°C分辨率:0.02°C内置相对湿度传感器工作范围:0%RH~100%RH分辨率:0.05%RH存储器数据采样能力:122,197 12位样本采样频率: 频率可调 (10秒间隔),从10秒/次到1天/次尺寸85 x 59 x 26mm (3.4" x 2.3" x 1")
    留言咨询

温度湿度相关的方案

温度湿度相关的论坛

  • 实验室的温度湿度

    请大家将自己实验室的温度、湿度数据上传。格式如下:甘肃酒泉 温度22度 相对湿度8%

  • 温度湿度对漆膜的影响试验

    请问模拟集装箱内温湿度情况,如果采用可程式恒温恒湿试验机的话,这个温度湿度怎么设定比较好?整整5天集装内的温湿度。

  • 实验室温度 湿度

    实验报告温度:N/A ,湿度:N/A 是什么意思?N/A是什么英语单词的缩写呢?

温度湿度相关的资料

温度湿度相关的资讯

  • 恒奥德仪器温湿度压力检测仪/温度湿度压力三合一检测仪/数字温湿度大气压力计H17888
    温湿度压力检测仪/温度湿度压力三合一检测仪/数字温湿度大气压力计H17888产品概述:数字温度大气压力计是新一代便携式测量大气压仪表,仪表采高精度隔膜式绝压传感芯片,液晶数字双排显示,方便直观地测量外界大气压力,温度数值。采用全数字化设计,可靠性强体积小,重量轻,手感好,操作简便。该仪表广泛用于气象、科研、环保、军事、体育,是各实验室的须备常用仪表。 技术参数:数字温湿度大气压计基本技术参数:1、大气压测量范围:300~1100hPa2、大气压精度:0.5%FS(300~1100hPa)3、分辨率:0.1hpa / 0.1℃/ 0.1RH%4、测量介质:大气5、温度测量范围:-30~60℃6、温度测量精度:0.5℃7、湿度测量范围:0~100RH%8、湿度测量误差:±3%9、使用环境:温度-40~100℃;湿度0~100RH%10、电源:AA碱性五号电池4节11、尺寸重量:150×75×30mm约180g 大气压力单位换算表:1标准大气压(atm)760mmHg(毫米汞柱)76cmHg (厘米汞柱)10.336mH2O(米水柱)1013.25mba(毫巴)1.013×105pa(帕)1013hpa(百帕)101.3Kpa(千帕)【备注】十届国际计量大会决议声明,规定标准大气压值为1标准大气压=101325牛顿/米2 数字温湿度大气压计特点:◎ 双排LCD液晶显示,大气压、温度和湿度数字直读。◎ 进口高精度绝压传感器、高分辨率、高稳定性。◎ 进口超低功耗单片微电脑,并具有数值稳定功能。◎ 仪表数字校准,不用任何硬件调整。◎ 具有使用范围广,适合各种工况状态下使用。◎ 体积小、质量轻、便于携带,适合室内和野外作业。◎ 四节干电池供电,屏幕电量显示,电池连续使用可达50小
  • 张承青电镜实验室环境约稿[8]:温度湿度和风速噪声(还有结束语)
    为促进电子显微学研究、电镜应用技术交流,打破时空壁垒,仪器信息网邀请电子显微学领域研究、技术、应用专家,以约稿分享形式,与大家共享电子显微学相关研究、技术、应用进展及经验等。同时,每期约稿将在仪器信息网社区电子显微镜版块发布对应互动贴,便于约稿专家、网友线上沟通互动。专家约稿招募:若您有电子显微学相关研究、技术、应用、经验等愿意以约稿形式共享,欢迎邮件投稿或沟通(邮箱:yanglz@instrument.com.cn)。本期将分享张承青老师为大家整理的关于电镜实验室环境对电镜的影响的系列约稿经验分享,以下为系列之八,以飨读者。(本文经授权发布,分享内容为作者个人观点, 仅供读者学习参考,不代表本网观点)系列之八 温度湿度和风速噪声(还有结束语)先说说温度。电镜实验室对温度要求其实并不高,一般从舒适性、节能等方面考虑,可以选择夏天26度冬天20度。实际上电镜对温度变化率要求较高,常见的有≦0.5℃/3分钟、≦0.5℃/5分钟等。一般好一点的中央空调基本都可以满足要求(实测某国产名牌柜式空调,四分钟为一循环周期,上下波动1℃)。曾有选用精密空调的,意义不大(从价格、维护成本、适用性等方面考虑)。其实越是精度高的电镜越是厚重,热容量也就越大,只要房间内温度变化绝对值不是很大,短时间内温度上下略有跳动很难看出影响。电镜室内的温度也不宜过低,那样冷却水管、液氮管和杜瓦瓶等处容易结露滴水。某老式能谱仪的线路板设计不妥,直接就在液氮杜瓦瓶下方,稍不当心就因为结露滴水烧毁线路板。至于辅助设备间,因为循环冷却水箱、空压机、UPS、真空泵等都是发热大户,所以必须按照设备说明书给出的发热量来计算所需的空调机规格。此前闲暇时曾经一一查过说明书,空压机、UPS、真空泵等都明确说明可在55℃或70℃下工作。虽然辅助设备间温度怎么也不会到那么高,但也说明问题不大,本人曾在盛夏天气维修某大学的循环冷却水箱,当时一进辅助间热浪扑面而来,测得温度高达40℃,各辅助设备正常工作平安无事。不过有一点必须注意,辅助间温度过高会降低循环冷却水箱的冷却效率,致使冷却水出口水温偏高,严重时会致使透镜的热漂移加大,所以建议辅助间温度全年都不要高于35℃就可以啦。再来看看湿度。冷冻样品对湿度要求很高,有些用户希望相对湿度在25%以下。但是湿度过低很容易产生静电,一会来一下一会来一下,那滋味也不好受。我们的对策是把冷冻制样机搬到电镜近旁,尽量缩短冷冻样品在室内的暴露时间,同时尽量加快操作速度、缩短在空气中的暴露时间,这样就可以适当减低湿度要求。一般电镜室的相对湿度在65%以下就可以,这个要求其实很低,一般空调都很容易达到(当然必须保持房门关闭,尽量缩短人员进出的开门时间)。如果是一年以内的新房子,建筑湿气短期无法排除,那么可以临时性适当配备去湿机就可以搞定(注意排水哦)。还可以在中央空调的风路上加电热板去湿,不过这样可能要多花些钱,效果嘛,差不多吧。空调送风有时令人纠结。风小了吧,难以保证空调正常工作;风大了吧,又怕超过电镜要求标准。其实在大多数情况下只要在规划电镜室室内布局时,注意空调出风口(无论挂机或者柜机)不要正对镜筒就是了。对于要求高的电镜可以考虑用布袋送风。从风量=风速×风口面积可知,加大面积就可以在保证送风量不变前提下减小风速。南京某大学有一个成功案例:电镜室约50平米,平面接近正方形,在房间两对角屋顶放置两个下送风风口(截面1m×1m),在另外两对角屋顶放置两个回风口(截面0.8m×0.8m)这样两对气流分别沿四面墙壁附近流动,很好完成送风任务的同时,还在镜筒(基本位于房间中央)附近形成一个“静风区”,多次测试风速达到0.00m/s(当时找不到精度更高的风速计)。另外有一种布袋式送风效果不错风速极小,可是对外观略有影响。噪声是另一个不大不小的问题。一般打电话的音量就会使100kx以上的图像产生水平干扰条纹(类似于磁场干扰产生的毛刺,不过往往从上至下是分段的)。如果不能将噪声源(幸好噪声干扰频率一般在50~2000 Hz,我们人类可以直接听到并大致判断大小强弱)搬离至远处,那就只有在四壁和顶面铺装经过阻燃处理的泡沫材料吸音这唯一的一招了,这时墙面自然要选用微孔板(铁板、铝塑板均可)。一般40~80mm厚的泡沫材料,即可以产生明显吸音效果。一般情况下,关上门,不说话,噪声干扰就不大。结束语本系列讨论到此就要结束啦。在电子显微镜的设计制造方面,我们与世界先进水平相比还有很大差距,这点必须承认。但由于我国地域辽阔,各地环境又是千差万别,从山顶到山沟、从高楼到地下、从静谧的校园到嘈杂的工厂、从山腰巨岩到黄土高坡、从喧哗市区到宁静原野、从青藏高原到海边沙滩、从地铁站上方到高铁线近旁、从振动磁场都异常复杂的钢厂到半导体厂的超净间,到处都有电镜实验室,这样我们就得到了各种情况下的实践机会,进而得到许多实践经验和实测数据(包括正反两面)。所以,在电镜环境改善技术领域,我们丝毫没有落后于人,甚至可以说是后来居上走在了业界的前列。由于本人条件所限,再继续深入下去就很困难了。有幸借仪器信息网平台,传递一些体验,发布一些领悟,以抛砖引玉,为促进我国的电镜事业发展,尽绵薄之力。最后,预祝朋友们将来取得更大成就!2020.11张承青作者简介作者张承青,退休前在某电镜公司工作多年,曾经做过约两千个(次)电镜环境调查、测试,参与多个电镜实验室设计及改造设计规划,在低频电磁环境改善和低频振动改善等方面有些体会,迄今仍在这些方面继续探索。附1:张承青系列约稿互动贴链接(点击留言,与张老师留言互动): https://bbs.instrument.com.cn/topic/7655934_1附2:张承青系列约稿发布回顾拟定主题发布时间文章链接序言 电镜实验室环境对电镜的影响2020年10月13日链接系列之一 电子显微镜实验室环境调查的必要性2020年10月15日链接系列之二 电镜实验室的电磁环境改善2020年10月20日链接系列之三 低 频 电 磁 屏 蔽 实 践2020年10月22日链接系列之四 主动式低频消磁系统2020年10月27日链接系列之五 几种改善电磁环境方法比较2020年10月29日链接系列之六 低频振动环境改善2020年11月3日链接系列之七 谈谈电子显微镜的接地2020年11月5日链接系列之八 温度湿度和风速噪声2020年11月11日本文… … … … … … 附3:相关专家系列约稿安徽大学林中清扫描电镜系列约稿
  • 应用案例 | 使用开路传感器系统研究温度和湿度对N2O吸收谱和浓度的影响
    近日,来自山东师范大学物理与电子科学学院的联合研究团队发表了一篇题为Effects of Temperature and Humidity on the Absorption Spectrum and Concentration of N2O Using an Open-Path Sensor System的研究论文。IntroductionSince China’ s proposal of the “carbon peak” and “carbon neutrality” goals, the government and society have attached great importance to the problems of air pollution and global warming. Nitrous oxide (N2O) is among the six greenhouse gases under the Kyoto Protocol. N2O content is relatively low compared to carbon dioxide (CO2), but its global warming potential is about 310 times that of CO2. In addition, it is destructive to ozone (O3). There are many reasons for the changes in N2O concentrations in the atmosphere, which are partly due to anthropogenic activities, such as the widespread use of fertilizers in agricultural activities. The concentrations of other gases in the atmosphere, as well as the wind speed and direction, are all correlated with changes in N2O concentrations. At the macro level, temperature and humidity are also factors affecting the absorption coefficient of N2O gas. However, relatively few studies have been conducted on the specific effects of temperature and humidity on N2O gas, and analysis has also been lacking on the influence of temperature and humidity on the absorption spectrum and the concentration of N2O. Moreover, some uncertainty and variability remain in the observations of the relationship between N2O gas concentrations and temperature and humidity. The reasons for these discrepancies may be regional differences, differences in observation methods, and imperfections in data, which are all important bases for measuring the N2O concentration in atmospheric, medical, combustion, and agricultural processes. Thus, further research and exploration, combined with additional field observations and modeling experiments, can uncover the mechanism of temperature and humidity on the N2O concentration. Consequently, providing a scientific basis for this concentration is essential for reducing N2O emissions, controlling climate change, and promoting sustainable development and environmental protection. 简介自中国提出“碳峰值”和“碳中和”目标以来,政府和社会对空气污染和全球变暖问题给予了极大关注。N2O是《京都议定书》下的六种温室气体之一。与二氧化碳(CO2)相比,N2O含量相对较低,但其全球变暖潜力约为CO2的310倍。此外,它对臭氧(O3)具有破坏性。大气中N2O浓度的变化有许多原因,部分原因是人类活动造成的,例如在农业活动中广泛使用化肥。大气中其他气体的浓度以及风速和风向都与N2O浓度的变化相关。在宏观水平上,温度和湿度也是影响N2O气体吸收系数的因素。然而,对温度和湿度对N2O气体具体影响的研究相对较少,对温度和湿度对N2O吸收谱和浓度的影响分析也不足。此外,在N2O气体浓度与温度和湿度之间的关系观察中仍存在一些不确定性和变异性。导致这些差异的原因可能是地区差异、观测方法差异以及数据的不完善,这些都是测量大气、医疗、燃烧和农业过程中N2O浓度的重要基础。因此,进一步的研究和探索,结合更多的现场观测和建模实验,可以揭示温度和湿度对N2O浓度的机制。因此,为减少N2O排放、控制气候变化,促进可持续发展和环境保护提供科学依据至关重要。Experimental DetailsSensor SetupBased on WMS technology and an open optical path, an open optical-path detection system for detecting N2O gas in the atmosphere was built. The schematic diagram is shown in Figure 1. The sensor system is composed of a light-source module, photoelectric Remote Sens. 2023, 15, 5390 4 of 11 detection module, and data processing module. The light-source module mainly consists of signal generation, a laser drive, QCL, and an indication light source. To effectively realize the tunable characteristics of laser emission wavelength, we designed the signal generator plate to generate a high-frequency sine wave signal with a frequency of 10 kHz to realize the modulation function and to generate a low-frequency sawtooth wave signal with a frequency of 10 Hz to realize the scanning function. The two signals are superimposed on the laser driver, controls the temperature and central emission wavelength of QCL and converts it into an injection current acting on the detection light source QCL so that the emission wavelength of QCL is in the tunable range of 2203.7–2204.1 cm&minus 1.实验细节传感器设置基于波长调制光谱学(WMS)技术和开路光学路径,建立了一种用于检测大气中N2O气体的开路光学路径检测系统。示意图如图1所示。该传感器系统由光源模块、光电检测模块和数据处理模块组成。光源模块主要包括信号生成、激光驱动、量子级联激光器(QCL)和指示光源。为了有效实现激光发射波长的可调特性,我们设计了信号生成器板,生成频率为10 kHz的高频正弦波信号以实现调制功能,并生成频率为10 Hz的低频锯齿波信号以实现扫描功能。这两个信号叠加在激光驱动器上,控制QCL的温度和中心发射波长,并将其转化为作用于检测光源QCL的注入电流,使QCL的发射波长处于2203.7–2204.1 cm-1的可调范围内。Figure 1. Schematic diagram of N2O open optical sensor system.项目使用的激光驱动器是宁波海尔欣光电科技有限公司的QC750-TouchTM量子级联激光屏显驱动器。&bull 集成电流及温控驱动,功能完备;&bull 温度控制驱动采用非PWM式的连续电流输出控制,大大延长TEC器件的使用寿命;&bull 多种输出安全保护机制,保护QCL使用安全:可调电流钳制、输出缓启动、过压欠压保护、超温保护、继电器短路输出保护;&bull 大电流软钳制功能,避免误操作大电流损坏激光管;&bull UI界面显示便于用户操作使用及数据观测;&bull 全自主研发,集成度高,性价比高。QC750-TouchTM, Ningbo HealthyPhoton Technology, Co., Ltd.Selection of N2O TransitionsTo achieve effective detection of N2O gas molecules, we need to select the absorption line intensity and the emission central wavelength of the laser. First, combined with the HITRAN-2016 database, the wave number range of 2000–2250 cm&minus 1 was selected to analyze the region of the absorption spectral line intensity of N2O, and then carbon monoxide (CO), carbon dioxide (CO2), and water (H2O) molecules were simulated and analyzed, as shown in Figure 2. Within this wave number range, the absorption spectra of CO2 were mainly distributed within the 2000–2081 cm&minus 1 range, and the absorption spectra of CO gas were distributed within the 2025–2200 cm&minus 1 wave number range. The absorption spectra of N2O gas were distributed before the 2020 cm&minus 1 wave number range. The absorption spectra of N2O gas molecules were mainly distributed in the 2200–2250 cm&minus 1 wave number range, and they were far from the absorption spectra of water vapor and other gases, reducing interference. At around 2203.7 cm&minus 1 , the absorption spectra of N2O gas were the strongest. Therefore, we set the position of the N2O absorption line to 2203.7333 cm&minus 1, which was used as the wave number of the QCL emission center. The corresponding spectral line intensity was 7.903 × 10&minus 19 (cm&minus 1 .mol&minus 1 ). The central current and temperature of QCL were set at 330 mA and 36.0 ◦ C, respectively.N2O跃迁的选择为了有效检测N2O气体分子,我们需要选择吸收线强度和激光的发射中心波长。首先,结合HITRAN-2016数据库,选择了2000–2250 cm&minus 1的波数范围,以分析N2O吸收光谱线强度的区域,然后对一氧化碳(CO)、二氧化碳(CO2)和水(H2O)分子进行了模拟和分析,如图2所示。在这个波数范围内,CO2的吸收光谱主要分布在2000–2081 cm&minus 1范围内,CO气体的吸收光谱分布在2025–2200 cm&minus 1波数范围内。H2O气体的吸收光谱分布在2020 cm&minus 1波数范围之前。N2O气体分子的吸收光谱主要分布在2200–2250 cm&minus 1波数范围内,远离水蒸气和其他气体的吸收光谱,减少了干扰。在2203.7 cm&minus 1左右,N2O气体的吸收光谱最强。因此,我们将N2O吸收线的位置设置为2203.7333 cm&minus 1,用作QCL发射中心的波数。相应的光谱线强度为7.903 × 10&minus 19(cm&minus 1mol&minus 1)。QCL的中心电流和温度分别设置为330 mA和36.0 ℃。Figure 2. The intensity distribution of absorption lines of N2O, CO, CO2, and H2O in the range of 2000–2250 cm&minus 1.ConclusionsIn this study, we investigated the effects of temperature and humidity on the concentration of N2O and its absorption spectra using an open-path sensor system. By combining theoretical analysis and field monitoring, we first conducted monitoring of N2O in a campus environment, analyzing the effects of temperature on its concentration and absorption spectra. We discovered that the concentration of N2O would increase correspondingly with the increase in temperature. The influence of humidity on N2O concentration was monitored under the condition that the ambient temperature of the laboratory remained unchanged. The concentration of N2O was negatively correlated with humidity. The 2f and 1f signals under different temperature and humidity levels were extracted for analysis. We found that the higher the temperature, the smaller the peak value of the 2f and the 1f signals, which accords with the trend of the Gaussian function changing with temperature. Under different humidity conditions, the lower the humidity, the larger the 2f signal peak the higher the humidity, the smaller the 2f signal. This study is of great significance for analyzing the relationship between N2O and environmental parameters such as temperature and humidity. We hope that our research findings can assist environmental agencies in formulating more effective environmental policies for different environments. In the future, we can use QCL to analyze the relationship between N2O and other environmental and gas parameters.结论在本研究中,我们利用开路传感器系统研究了温度和湿度对N2O浓度及其吸收光谱的影响。通过理论分析和现场监测相结合,我们首先在校园环境中进行了N2O监测,分析了温度对其浓度和吸收光谱的影响。我们发现随着温度升高,N2O浓度相应增加。在实验室环境中,保持环境温度不变的条件下监测了湿度对N2O浓度的影响。N2O浓度与湿度呈负相关。在不同温度和湿度水平下提取并分析了2f和1f信号。我们发现温度越高,2f和1f信号的峰值越小,这与高斯函数随温度变化的趋势相符。在不同湿度条件下,湿度越低,2f信号峰值越大;湿度越高,2f信号越小。这项研究对分析N2O与温度、湿度等环境参数之间的关系具有重要意义。我们希望我们的研究结果能够协助环境机构为不同环境制定更有效的环境政策。未来,我们可以利用QCL来分析N2O与其他环境和气体参数之间的关系。参考:Effects of Temperature and Humidity on the Absorption Spectrum and Concentration of N2O Using an Open-Path Sensor System, Remote Sens. 2023, 15, 5390.