四种阴离子

仪器信息网四种阴离子专题为您整合四种阴离子相关的最新文章,在四种阴离子专题,您不仅可以免费浏览四种阴离子的资讯, 同时您还可以浏览四种阴离子的相关资料、解决方案,参与社区四种阴离子话题讨论。
当前位置: 仪器信息网 > 行业主题 > >

四种阴离子相关的耗材

  • 7种混合阴离子对照品 I, 50 mL
    7种混合阴离子对照品 I, 50 mL
  • 进口液相柱 阴离子交换柱---PRP-X100
    PRP-X100柱用于分离10-500ppm的有机和无机阴离子。粒径选择有3、5、10和12-20mm四种;柱子内径有8种规格,从1.0-50.8mm;柱管材料:316不锈钢或PEEK。①分离8种常见阴离子,从F到SO24②可用0-100%有机溶剂③PH0-14稳定;可用电导和UV检测器
  • 056933 美国赛默飞标准品 Dionex七种阴离子标样标准品
    Dionex 离子标样浓缩液Thermo Scientific™ Dionex™ 离子标准品结合离子、氟离子和硫酸根用于各种常规阴离子、阳离子和标准品测定。订货信息:五种阴离子标样组合装100 037157七种阴离子标样组合装 I 50 056933七种阴离子标样组合装 II 100 057590氟离子标样 (1000mg/L) 100 037158氯离子标样 (1000mg/L) 100 037159硫酸根离子标样 (1000mg/L) 100 037160六种阳离子标样组合装-I 50 040187六种阳离子标样组合装-II 50 046070描述容量 (mL) 部件号一氯乙酸 -2-13C 内部标样, 1000mg/L MtBE 溶液1 069406一溴乙酸 -1-13C 内部标样, 1000mg/L MtBE 溶液1 069407二氯乙酸 -2-13C 内部标样, 1000mg/L MtBE 溶液1 069408三氯乙酸 -2-13C 内部标样, 1000mg/L MtBE 溶液1 069409

四种阴离子相关的仪器

  • Natrix®膜含有高密度惰性纤维网络骨架,内部充填多孔聚丙烯酰胺水凝胶,并结合了相应的官能团。内部交互的多孔结构(孔径为0.4 µm)具有非常大的表面积,可以提供更高的蛋白结合和透过性。Natrix® Q是一款高载量和高通量的强阴离子交换膜层析产品,用在流穿条件下纯化生物分子,如单抗。独特的Natrix® Q膜拥有直接聚合在多孔膜骨架内的高密度季胺基官能团。Natrix® Q膜的交互多孔结构和高密度配基,能够实现高流速下的超高通量和上样量,并在这些极端操作条件下仍保持杂质去除的优异能力。Natrix® Q膜可为生物工艺提供生产力、灵活性和工艺稳定性方面更高的选择。优势:- 优秀的HCP去除、DNA去除和病毒清除能力- 盐和pH的高耐受性(即使磷酸盐缓冲液体系)- 精纯过程保持高通量和高载量( 10 kg/L)- 易于放大和优化的高通量纯化解决方案- 操作灵活(宽泛的上样量、流速和缓冲液条件)- 提高生产力、降低操作复杂性、提高工艺的稳定性和经济性- 简单、低成本的精纯操作- 稳定、安全的供应链、以及验证和法规支持Natrix® Q产品系列(小试、中试以及生产型)提供从研发到cGMP生产的不同规格精纯产品:- Recon Mini, 0.2 mL- Pilot, 15 mL- Process, 115/460 mL更多信息,e.g., 层析膜表现,详细性能列表等,可参见本页面核心参数 – 样本下载中的资料手册。
    留言咨询
  • 仪器简介:能简便、快捷、准确、经济地测量水溶液中的银离子和硫离子。但由于硫化银为不溶物,所以实际上银离子和硫离子不会同时存在于溶液中。此电极还可进行低浓度氰化物和卤化物滴定。技术参数:9616BNWP银/硫离子复合电极技术参数 电极型号 9616BNWP 测量范围 0.003 ~ 32100 ppm pH范围 2 ~ 12 pH 温度范围 0-80℃ 连续测量 80-100℃ 间歇测量 重现性 银离子± 2%;硫离子± 4% 样品 水溶液 电极尺寸 电极长度:110mm 电极体直径:13mm 电极帽直径:16mm 电缆线长度:1m Dual Star双通道pH/离子浓度测量仪主机技术参数: 离子浓度 测量范围:0 &ndash 19999 分辨率:1,2,3 位有效数字 相对精度:± 0.1 mV 或0.05%(取较大者) 单位:ppm,mg/L,M,% 或无单位 测量方法:单已知加量/ 减量法;双已知加量/ 减量法 校正点:2- 6 点 pH 测量范围:-2.000 - 19.999 分辨率:0.1 / 0.01 / 0.001 pH 相对精度:± 0.001 pH 校正点:1 - 6 点 自动缓冲液识别:US,NIST,DIN 和用户自定义 氧化还原电位 (ORP) 测量范围:± 1999.9(mV/RmV/EH) 分辨率:0.1 mV 相对精度:± 0.1 mV 或0.05%(取较大者) 温度 测量范围:-5 - 105℃ 分辨率:-5 - 99.9℃为0.1℃,99.9℃以上为1.0℃ 相对精度:± 0.1℃ 仪表功能 LCD :双通道显示 输入:两个BNC 接口,两个参比电极接口,两个MiniDIN 接口(温度探头) 方法存储:20 个 密码保护:是 数据存储:1000 组 符合GLP 标准:是 数据传输:双向RS232 接口,可选USB 电缆 IP 等级:IP54 防尘防溅 质量安全认证:CE,CSA,UL,TÜ A,FCC Class A 操作环境:适宜操作温度5 - 45℃ 相对湿度5 - 85%(无冷凝) 电源:4× AA 电池,通用的电源适配器 外形尺寸:9.4 cm(高)× 17.0 cm(宽)× 22.4 cm(长) D10P-16 Dual Star银离子测量仪套装: &bull Dual Star双通道pH/离子浓度测量仪 &bull 9616BNWP银/硫离子复合电极 &bull 927007MD温度电极 &bull 离子强度调节剂 &bull 电极填充液 &bull 搅拌器 &bull RS232数据线 &bull 电极支架 配件及耗材: 9616BNWP 银/硫离子复合电极 900067 Optimum ResultTM C,电极填充液,用于银离子测量,5x60mL 900061 Optimum ResultTM A,电极填充液,用于硫离子测量,5x60mL 900062 Optimum ResultTM B,电极填充液,用于通用测量,5x60mL 940011 离子强度调节剂,5M NaNO3,475mL 941609 硫化物抗氧化缓冲剂(SAOB II) 948206 高氯酸铅溶液(0.1M),475mL 948201 24张6&rdquo 抛光纸主要特点:Dual Star银离子测量仪 &bull 双通道结构具备双BNC接口,双参比接口,双ATC接口,可同时接入两支离子选择性电极或pH电极,对样品中的离子浓度或pH同时测量,同时显示。 &bull 可与银、氯、氨氮、氟、钠、钾、溴、硝酸根等离子选择性电极(ISE)或pH电极搭配使用,测量溶液中的离子浓度或pH值。 &bull 数字按键便于操作仪表。 &bull 可同时显示被测离子的名称,浓度值,mV值,温度。 &bull 包含针对复杂样品测量的已知加量/减量法,样品加量/减量法。 &bull 自动空白校准功能。 &bull 升级的GLP性能,可设置仪表密码并为每种方法单独设置密码。 &bull 每通道可设置10个测量方法-不同电极的校准数据。 &bull 可存储1000组带日期、时间的数据。 &bull 可通过USB接口更新软件。 &bull 以图形方式显示校准曲线。 &bull 可与自动换样器连用。 &bull 可设置等温点以及温度校准。
    留言咨询
  • 二手离子色谱仪检测乳制品中阴离子 检测样品:乳制品检测项目:碘离子和硫氰酸根离子检测器仪器:离子色谱仪 健康牛的牛奶中平均含有0.9mg/kg的硫氰酸根,是乳制品过氧化物酶抗菌体系主要成分之一。但有些不法奶户为了延长原料乳的保质期,人为加入硫氰酸盐作为生牛奶保鲜剂。 碘是影响身体和智力发育的必要元素,国家标准对每100 g奶粉的碘含量要求是30至150μg,碘摄取不足或过量都会引起甲状腺肿大的疾病。由于儿童比成人更容易因碘缺乏或过量导致甲状腺肿大,而且婴幼儿所需碘主要来源于母乳及奶粉,所以对孕妇体液碘的监控和婴幼儿奶粉中碘的检测十分必要。 碘离子的分析方法有很多,如示差脉冲溶出伏安法、催化荧光法、电感耦合等离子体-原子光谱或质谱法、反相离子对色谱法和离子色谱法等,碘离子的紫外检测方法灵敏度远高于电导检测。硫氰酸根的检测方法有荧光动力学法、反相离子对色谱法和离子色谱法。 使用强亲水性阴离子交换色谱柱分离,紫外和电导两种检测方式串联检测,利用电导的检测结果来判断紫外检测的色谱峰纯度,并指导色谱条件的优化,通过紫外检测器获得高灵敏度的碘离子检测结果。硫氰酸根的紫外和电导检测方式灵敏度相近,电导检测方式干扰更少,准确度更高。 根据上述离子色谱仪检测乳制品中阴离子,京科瑞达科技为您提供的仪器如下: 赛默飞 ICS-3000 离子色谱仪 赛默飞 ICS-3000是高端研究用色谱系统,其功能整合了离子色谱、生物液相、氨基酸分析的全部应用,全新的模块设计具有大大的灵活性、功能更全,操作更简便,其出彩的性能将色谱分析带入一个更高境界。
    留言咨询

四种阴离子相关的方案

  • 离子色谱法测定食物添加剂磷酸二氢钙中的阴离子
    目的建立一种同时测定磷酸二氢钙中的F- 、Cl- 、SO42- 、NO3- 四种阴离子的分析方法。方法以碳酸钠和氢氧化钠溶液为淋洗液,通过对淋洗液等色谱说明前提的优化,选择离子色谱法测定食物添加剂CaH2 PO4中的阴离子,以尺度物质保存时刻定性,以外标法定量。功效在优化的色谱前提下,4 种离子的疏散度好,检测迅速度高 被测离子的浓度在必然范畴内与色谱峰面积呈精采的线性相关,相相关数r > 0. 999。4 种离子测定功效相对尺度毛病均< 3% ( n = 9) ,均匀加标接纳率为80% ~ 105% 。结论离子色谱法轻盈、迅速、快速,可以或许满意同时测定CaH2 PO4中4 种阴离子含量的要求。
  • 青岛盛瀚:离子色谱法测定食物添加剂磷酸二氢钙中的阴离子
    目的建立一种同时测定磷酸二氢钙中的F- 、Cl- 、SO42- 、NO3- 四种阴离子的分析方法。方法以碳酸钠和氢氧化钠溶液为淋洗液,通过对淋洗液等色谱说明前提的优化,选择离子色谱法测定食物添加剂CaH2 PO4中的阴离子,以尺度物质保存时刻定性,以外标法定量。功效在优化的色谱前提下,4 种离子的疏散度好,检测迅速度高 被测离子的浓度在必然范畴内与色谱峰面积呈精采的线性相关,相相关数r > 0. 999。4 种离子测定功效相对尺度毛病均< 3% ( n = 9) ,均匀加标接纳率为80% ~ 105% 。结论离子色谱法轻盈、迅速、快速,可以或许满意同时测定CaH2 PO4中4 种阴离子含量的要求。
  • 离子色谱检测药物中阴离子及有机酸的应用
    离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用离子色谱检测药物中阴离子及有机酸的应用

四种阴离子相关的论坛

  • 雾霾中四种阴离子混标配制的心得体会

    雾霾中四种阴离子混标配制的心得体会

    雾霾中四种阴离子混标配制的心得体会标准曲线的配制是实验中必不可少且十分重要的一环,这关系到实验结果的计算和准确性。常见的有单标和混标的配制,在实际工作中混标的配制还是占比非常大的,今天主要讨论一下雾霾中四种阴离子混标配制过程中的注意事项。我们单位有常规雾霾监测的任务,每个月都要进行,最近我在跟着用[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url]测定雾霾中四种常见的阴离子,包括F[sup]-[/sup]、Cl[sup]-[/sup]、SO[sub]4[/sub][sup]2-[/sup]、NO[sub]3[/sub][sup]-[/sup],采用标准溶液稀释法配制混标。四种阴离子母液浓度均为1000 mg/L,配制到250ml容量瓶中,五个标准点浓度如下表所示,根据公式[img]https://ng1.17img.cn/bbsfiles/images/2023/10/202310241023299508_9460_5814575_3.png[/img][font=calibri]计算出所需体积。(其中[/font]由于混标中F[sup]-[/sup]浓度较低,因此要先将母液稀释成100 mg/L的中间液,再继续配制)[table][tr][td][/td][td][align=center][color=black]标1[/color][color=black]mg/L[/color][/align][/td][td][align=center][color=black]标2[/color][color=black]mg/L[/color][/align][/td][td][align=center][color=black]标3[/color][color=black]mg/L[/color][/align][/td][td][align=center][color=black]标4[/color][color=black]mg/L[/color][/align][/td][td][align=center][color=black]标5[/color][color=black]mg/L[/color][/align][/td][/tr][tr][td][align=center][color=black]F[/color][sup][color=black]-[/color][/sup][/align][/td][td][align=center][color=black]0.2[/color][/align][/td][td][align=center][color=black]0.4[/color][/align][/td][td][align=center][color=black]0.8[/color][/align][/td][td][align=center][color=black]1.2[/color][/align][/td][td][align=center][color=black]1.6[/color][/align][/td][/tr][tr][td][align=center][color=black]Cl[/color][sup][color=black]-[/color][/sup][/align][/td][td][align=center][color=black]10[/color][/align][/td][td][align=center][color=black]30[/color][/align][/td][td][align=center][color=black]50[/color][/align][/td][td][align=center][color=black]70[/color][/align][/td][td][align=center][color=black]100[/color][/align][/td][/tr][tr][td][align=center][color=black]SO[/color][sub][color=black]4[/color][/sub][sup][color=black]2-[/color][/sup][/align][/td][td][align=center][color=black]10[/color][/align][/td][td][align=center][color=black]30[/color][/align][/td][td][align=center][color=black]50[/color][/align][/td][td][align=center][color=black]70[/color][/align][/td][td][align=center][color=black]100[/color][/align][/td][/tr][tr][td][align=center][color=black]NO[/color][sub][color=black]3[/color][/sub][sup][color=black]-[/color][/sup][/align][/td][td][align=center][color=black]2[/color][/align][/td][td][align=center][color=black]5[/color][/align][/td][td][align=center][color=black]10[/color][/align][/td][td][align=center][color=black]20[/color][/align][/td][td][align=center][color=black]30[/color][/align][/td][/tr][/table]有以下几点在配制过程中需要注意:1、使用[url=https://insevent.instrument.com.cn/t/9p][color=#3333ff]移液枪[/color][/url]要注意垂直取样,慢吸快打。2、根据所需体积及量程选取合适的[url=https://insevent.instrument.com.cn/t/9p][color=#3333ff]移液枪[/color][/url],[url=https://insevent.instrument.com.cn/t/9p][color=#3333ff]移液枪[/color][/url]使用次数要在满足取样要求的前提下尽可能少,且尽量使用同一把[url=https://insevent.instrument.com.cn/t/9p][color=#3333ff]移液枪[/color][/url]减少误差。3、先把一个阴离子的5个标准点分别取完之后再取下一个阴离子,这样能减少换枪头的次数精简操作过程且不容易产生混乱。4、计算过程要准确且要规范工整做好笔记,有一次配制时由于书写时未做好标注就把浓度那一行看成所需要取样的体积了导致出现错误。5、注意库存和购买计划,在配制过程中发现F[sup]-[/sup]用量较小,而Cl[sup]-[/sup]、SO[sub]4[/sub][sup]2-[/sup]用量很大,这就需要在购买时改变比例,用的多的多买一些,用的少的少买一些,上次出错之后发现Cl[sup]-[/sup]、SO[sub]4[/sub][sup]2-[/sup]库存很少,险些不能按时完成实验任务。标准曲线配制次数多了就能一次次优化实验流程,希望大家都能配出满意的工作曲线!

  • 离子色谱法测定硼酸中的常见阴离子

    陈永欣(浙江大学西溪校区化学系, 杭州310028)摘 要 采用[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url]法成功地测定了硼酸中的常见阴离子。用硼酸-氢氧化钾作为淋洗液,EGC在线产生高纯度的KOH,控制硼酸离子调节淋洗液离子浓度,方便地实现梯度淋洗,柱后电化学抑制器使背景电导大大降低,可以实现常见阴离子(F-、Cl- 、NO2 –、Br-、NO3-、PO43-、 SO42-)高灵敏度分离和检测。该方法有较好的线性、检测限和重现性。检测限分别为0.001,0.001,0.004,0.004,0.003,0.01,0.04 mg/L;样品测定的回收率分别为98.5,99.4,100.0,99.7,99.7,101.2,100.1%。关键词 [url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url],硼酸,阴离子Determination of ordinary anions in boric acidYongxin Chen(Department of Chemistry ,Xixi Campus, Zhejiang University, Hangzhou 310027)Abstrace: In this paper, the ordinary anions were determined by using ion chromatography. By using boric acid and KOH, which was generated from EGC, ionic strength can be controlled easily and gradient elution can also be performed. After suppression very low conductance background can be obtained and sensitivity of anions has been greatly improved. With this method, good linear relationship, sensitivity and reproducibility were obtained. Detection limits of these anions were 0.001,0.001,0.004,0.004,0.003,0.01,0.04mg/L respectively. Rate of recovery were 98.5,99.4,100.0,99.7,99.7,101.2,100.1 % respectively.Keywords: ion chromatography , boric acid, anion1 引 言硼酸中的常规的阴离子的测定比较困难,虽然氢氧化钾作为淋洗液可以很好的使普通样品中的阴离子出峰,但是在背景较大的硼酸溶液中会产生对检测不利的硼酸背景峰,采用柱后抑制可以很好的把硼酸根的峰消除。研究发现用硼酸-氢氧化钾作为淋洗液可以比仅用氢氧化钾更好地分离常规阴离子,同时柱后电化学抑制器使背景电导大大降低,使得以前不能很好检测的硼酸中的阴离子成为可能。2 实验部分 2.1 仪器及试剂仪器:[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱仪[/color][/url],带EG50淋洗液发生器,Chromeleon色谱工作站,电导检测器,DSZ-IA电化学抑制器。色谱柱:IonPac AS14分离柱,IonPacAG14保护柱,(均为4mm)试剂:硼酸,分析纯;F-、Cl- 、NO2 –、Br-、NO3-、PO43-、 SO42-储备液,使用时稀释自所需浓度的标准使用液。溶液都用18.3MΩ.cm的二次去离子水配制。2.2 样品处理将硼酸稀释为2200μg/mL和22000μg/mL加标(F-0.01 mg/L,Cl-0.015 mg/L,NO2-、Br-、NO3- 0.025 mg/L,PO43-、SO42- 0.075 mg/L)后直接进样。 2.3 色谱条件淋洗液:采用淋洗液发生器产生的高纯KOH溶液;流速:1mL/min;自动再生抑制电流为100mA;进样量300µ L。3 结果与讨论3.1淋洗液条件的优化由于所需要测定的样品中阴离子含量较少,同时又由于样品中基体为高浓度的硼酸,若仅以常规方法分析,硼酸根离子峰会影响到别的离子的分离和分析。所以在淋洗液中加入高浓度的硼酸(100mM),并引入梯度淋洗,柱后添加较大电流进行电化学抑制,这样既增强了淋洗强度,抑制了硼酸根带来的峰,保证样品中常见阴离子得到很好的分离,改善各种离子的峰形和分离度,又使保留时间较长的离子在合适的时间出峰。采用的梯度淋洗条件见表1。表1 梯度淋洗的条件梯度程序时间(min)KOH浓度(×10-3mol/L)012612253025.01123.2重现性对硼酸加标样品进行重复性测定,重复进样11次考察其重现性。在所采用的色谱条件下,阴离子的重现性较好,它们保留时间的变异系数分别是:1.03%,1.09%,1.20%,1.01%,1.45%,1.32%,1.15%;峰面积的变异系数分别是:7.58%,4.05%,5.08%,3.27%,5.77%,3.62%,4.55%;峰高的变异系数分别是:5.75%,3.51%,4.00%,2.77%,4.26%,2.58%,3.32%,重现性较好。3.3线性关系和检测限在所采用的色谱条件下,对以上七种常见阴离子进行线性关系和检测限测定。它们的线性关系回归方程和检测限数据见表2。从线性关系和检测限可以看出,在一定的浓度范围内,四种物质均具有较好的线性关系和较低的检测限。表2. 七种常见阴离子的动作曲线线性、检测限阴离子anions回归方程regression equation相关系数r检测限(mg/L)detection limitF-Y=263.5x-15.450.99930.001Cl-Y=2103.3x+208.70.99990.001NO2–Y=120.8x+26.150.99900.004Br-Y=1419.2x-219.30.99890.004NO3-Y=318.15x-32.410.99970.003PO43-Y=522.89x+70.40.99940.01SO42-Y=1100x-156.450.99990.043.4样品测定和回收率测定  对实际样品用18.3MΩ.cm的二次去离子水稀释到指定浓度,经由0.2μm的过滤膜处理后直接进样,测定其中各阴离子的含量。样品的色谱图见图2.,样品中各阴离子含量及回收率数据见表3.图1. 硼酸2200 mg/L加标色谱图Figure 1. Chromatogram of boric acid(2200 mg/L)色谱图中1—F-(0.0135mg/L)、2—Cl-(0.041mg/L)、3—NO2 –(0.06mg/L)、4—Br-(0.038mg/L)、5—NO3-(0.049mg/L)、6—PO43-(0.118mg/L)、7—SO42-(0.091mg/L)、图2. 硼酸22000 mg/L加标色谱图Figure 2. Chromatogram of boric acid(22000 mg/L)色谱图中1—F-(0.045mg/L)、2—Cl-(0.275mg/L)、3—NO2 –(0.375mg/L)、4—Br-(0.155mg/L)、5—NO3-(0.265mg/L)、6—PO43-(0.450mg/L)、7—SO42-(0.235mg/L)、表3.样品(2200 mg/L)含量测定及回收率数据试样Analyte样品中阴离子含量Content(mg/L)加入标样量Sample added(mg/L)加标后总含量(mg/L)回收率% recoveryF-0.00350.010.013598.5Cl-0.0260.0150.04199.4NO2–0.0350.0250.060100.0Br-0.0130.0250.03899.7NO3-0.0240.0250.04999.7PO43-0.0420.0750.118101.2SO42-0.0160.0750.091100.13.4.机理探讨H3BO3/K+B(OH)4-H3BO3100mMEGC-KOH K抑制发生反应: 淋洗液浓度可以通过在线地添加KOH来调节,柱后电化学抑制,背景电导哪怕在梯度淋洗过程中也能很好地控制在同一水平。同时淋洗液中以100mM硼酸代替去离子水,OH-与硼酸生成硼酸根,大大增加了淋洗强度,有效地克服了基体硼酸浓度高的问题。4 结 论采用[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url]法,以硼酸-氢氧化钾为淋洗液,柱后电化学抑制,硼酸背景可以在运行中得到很好的控制,也就能减少样品中原有的硼酸根峰。较早出峰的离子(如氟离子)可以容易得到很好定量,用淋洗发生器可以很好地完成梯度淋洗,电化学抑制下的硼酸淋洗可以得到较稳定的背景。可以快速、准确、灵敏地分析基体含高浓度硼酸的常见阴离子。参考文献:1. 朱岩编著.[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url]原理及其应用.2002,6.2. 牟世芬,刘开录编.[url=https://insevent.instrument.com.cn/t/3p][color=#3333ff]离子色谱[/color][/url]方法及应用.2000,1.

  • 离子色谱 五种阴离子

    有没有大神 我想请教一下 五种阴离子 我们做盲样有数值 但是每次往里带入曲线看浓度 NO2- 和 NO3-的数值都不在范围内 一个高一个低 我们做曲线用的是五种阴离子混合标准物质大神 救命

四种阴离子相关的资料

四种阴离子相关的资讯

  • IC-MSMS极性阴离子型农残解决方案
    2019年11月5日,赛默飞在捷克布拉格的RAFA会议上正式发布了离子色谱和质谱联用的完整解决方案,专门用于食品中极性阴离子型农残分析。 农残检测一直是食品安全的重要项目,关乎民生,也是国内外公众共同关注的焦点问题。在GC、GCMS、LC和LCMS方法不断发展和完善的今天,仍然有一小部分的农药处于分析难点,无法做到尽善尽美。 例如以草甘膦、草铵膦、双丙氨膦、乙磷铝、乙烯利等为代表的极性阴离子型农药,它们具有分子量小,水溶性强、极性大的特点,常规反相色谱柱需要衍生化反应才能有所保留,Hilic色谱柱需要平衡时间长,重复性较差。 此外,欧盟在风险评估中,强烈建议将包含农残及其代谢产物在内的总和作为农药残留定义。例如草甘膦残留物包含了Glyphosate、AMPA、N-acetyl-AMPA和N-acetyl-glyphosate四种化合物总和。因此,最大残留量的限定就要求农残分析还需要有更高的灵敏度来满足更低含量测定的要求。极性阴离子型农残IC-MS/MS解决方案应运而生 针对极性离子型农残分析的特殊需求,赛默飞结合了离子色谱可以直接进样分析极性、离子型化合物的特点,兼具流路无金属材质的优势,与高灵敏度、高选择性的质谱检测器相结合,于2019年11月5日,在捷克布拉格的RAFA会议上正式发布了离子色谱和质谱联用的完整解决方案,专门用于食品中极性阴离子型农残分析,完全满足极性离子型农残分析的需求。一种全新的极性农药残留和污染物在食品分析中的解决方案——高灵敏度、高效、高耐受性的IC-MS/MS系统一针进样,同时分析15种化合物。该解决方案可以满足一针进样,同时分析15种化合物,包括极性阴离子型农残及其代谢物,以及常见阴离子型污染物。(Glyphosate、AMPA、N-acetyl-AMPA、N-acetyl-glyphosate、Glufosinate、N-acetyl-glufosinate、MPPA、Ethephon、Fosetyl-Al、Phosphonic acid、Cyanuric acid、Bialaphos、Chlorate、Perchlorate、HEPA)这套解决方案包含了样品前处理过程、仪器配置、耗材供应、软件方法预置和专业的技术支持:整套IC-MS/MS联用系统原理图:系统配置仪器配置方案优势(一)IC-MS/MS联用系统亮点1.阴离子交换柱,高效分离待测物,无需衍生,节约成本,简化分析流程。2.全流路PEEK材质,耐酸碱和有机溶剂,不与待测物络合干扰测定结果。3.EGC淋洗液在线制备,可提供稳定准确的等度和梯度淋洗功能,只加水就可以在线自动产生淋洗液,方便使用,降低泵头维护。4.在线电解抑制器提供持续稳定的抑制功能,使离子色谱系统与质谱兼容。5.Altis质谱检测器具备高灵敏度和高选择性特点。6.联用系统可以提供三重保护,确保质谱系统不被污染。 (二)方法验证与欧盟规定一致1.前处理方法优化本套解决方案会给客户提供优化后的前处理方法,参照欧盟实验室的QuPPe提取方法,针对不同种类的样品,优化提取过程和净化过程,赛默飞可以提供前处理相关的所有耗材。目前已有的相关前处理方法包括谷物、水果、蔬菜和婴幼儿食品等。后续还在继续开发不同样品的前处理方法… … 2.方法学验证本套解决方案的方法学验证工作,都是依照欧盟SANTE 11813/2017中的规定,包括线性考察、加标水平及重复性实验,所得全部结果都与该规定一致,满足回收率70%-120%,重复性RSDs小于20%的要求。 方案应用(一)灵敏度面粉被普遍认为是基质很复杂的一类样品,下图是在面粉基质中,标准曲线最低点(相当于4 ng/g样品含量)的峰形图。15种化合物的灵敏度均可满足欧盟要求。(二)回收率和重复性以面粉为例的10ng/g加标回收率结果,四种面粉样品结果如下图所示,满足EU SANTE 11813/2017中回收率在70%-120%,RSDs小于20%。(三)系统稳定性和耐受性以葱基质中的草甘膦为例,进样124针的离子对比例和保留时间统计:连续进样含基质样品500针前后峰形对比图:IC-MS/MS联用解决方案,帮助客户突破更多的技术难题,科研之路,赛默飞与你同在。色谱质谱明星产品前处理气相色谱离子色谱液相色谱气质联用液质联用AA/ICP/ICPMS软件 更多仪器配置和方案推荐色谱质谱全流程食品安全固废专项临床检测RoHS检测中药分析化药分析代谢组学
  • 透析分析——一种用于提取阴离子的新型电渗析装置
    收缩电渗析电渗析主要用于通过使用电场将水中带电的盐穿过离子交换膜拖到受体溶液,从而去除盐分并清洗水,从而将脏的咸水变成干净的新鲜饮用水。这样,电渗析通常在相当大的规模上进行。但是,通过将其缩小到较小的比例,由浙江大学的Yan Zhu领导的一组中国科学家表明,它也可以成为一种从液体样品中提取阴离子进行分析的有效方法。 为了共同采用电渗析进行分析,Zhu和他的同事开发了一种四层夹心设备,包括四个垂直堆叠的腔室。这些小室,每个40mm x 14mm,由三个膜,两个阳离子交换膜(CEM)和一个纤维素半透膜隔开。顶部和底部腔室均包含水作为电解质,并通过CEM与下一个腔室隔开。底部腔室上方的腔室容纳样品,而上方腔室-顶部腔室下方的腔室容纳水作为受体溶液。这些样品室和受体室通过纤维素半透膜彼此分开。垂直场这个想法是将水流泵入电解液室和接受室,而将液体样品泵入样品室。同时,沿腔室垂直向下施加电场,阴极在顶部,阳极在底部。该场将样品中的所有阴离子拉向阴极,使它们迁移穿过纤维素膜并进入受体腔室。但是它们无法通过形成该腔室顶棚的CEM,因此保留在受体溶液中,并随溶液流出设备并流向阴离子交换色谱柱进行分析。因此,这个想法相当简单,但是当Zhu和他的同事们在一种特殊制备的各种阴离子溶液(包括氟离子,氯离子和高氯酸根(ClO4–)上进行尝试时,他们发现反应室内的压力趋于波动,破坏了反应室中的压力。方法的效率。为了克服这个问题,他们尝试在泵入水和样品溶液之前用阳离子交换树脂填充腔室,发现这样做可以稳定压力。正如Zhu和他的同事在《色谱A杂志》(Journal of Chromatography A)上的一篇论文中报道的那样,当他们在阴离子溶液上测试该设备的版本时,他们发现该设备可以提取出93%至107%的回收率,并能将其富集。系数高达40。这使得该装置与固相萃取一样好。然后可以通过阴离子交换色谱法分离提取的阴离子,并用电导检测器以每千克浓度亚微克进行检测。 婴儿牛奶中的高氯酸盐的检测作为一项更具挑战性的现实测试,他们接下来尝试使用其电渗析设备从婴儿配方奶粉中提取阴离子。他们特别关注高氯酸盐,它具有潜在的毒性,因此在许多国家/地区,其在奶粉等食品中的浓度也受到严格监管。借助他们的设备,他们能够检测到16种奶粉样品中的高氯酸盐,其浓度范围从2.78μg/ kg到48.97μg/ kg。他们还用离子色谱-串联质谱法分析了牛奶样品,并测量了非常相似的高氯酸盐浓度,结果表明,用价格便宜得多的透析仪代替昂贵的质谱仪即可达到相同的准确度,而透析仪的生产成本仅为32美元。此外,通过简单地用阴离子交换膜和树脂替换阳离子交换膜和树脂并反转电场,该装置应该能够同样有效地提取阳离子。(编译:符斌 北京中实国金国际实验室能力验证研究中心研究员)根据An electrodialytic device for automated inorganic anion preconcentration with determination by ion chromatography-conductivity detection编写Published: Feb 08, 2021Authou: Ning Chen, Shuchao Wu,Yan Zhu
  • 赛默飞发布生物燃油中无机阴离子的测定方案
    2014年5月29日,上海——科学服务领域的世界领导者赛默飞世尔科技(以下简称:赛默飞)近日发布阀切换技术-离子色谱法测定生物燃油中的无机阴离子技术方案。原油是全球最主要的一次能源,当前世界上的能源短缺的实质就是原油短缺。其中,车用燃料占全球原油总消耗量的70%以上。严峻的能源短缺问题以及长期高居不下的油价引发了各界对可再生能源的探索与关注,其中,生物燃油的发展前景最为可观。举例来说,甲醇汽油就是一种“以煤代油”的有效路径——其常规排放低于常用汽油,非常规排放在现有技术下可以达到甚至超过常用汽油排放水平,并且,使用甲醇汽油不需要对汽车发动机进行改造,是非常理想的汽油替代物。然而,优质的生物燃油,对其中的无机盐等杂质的含量要求十分严格,因此有必要建立一种简便、灵敏、准确的测定甲醇汽油中无机盐的方法。离子色谱法是测定无机阴阳离子的理想方法,但甲醇汽油基体复杂,不能直接进入色谱柱,样品处理十分复杂,费时费力且容易受到其他因素的干扰。ICS-1600离子色谱系统赛默飞发布的生物燃油测定方案中建立了一种利用阀切换技术,直接进样在线前处理消除基体干扰,离子色谱法测定甲醇汽油中氯离子和硫酸根离子的分析方法。使用此方法检测生物燃油中的无机阴离子,无需繁复的样品处理步骤,在线可完成样品处理及分析,方法简便、快捷,准确度高,受其他因素干扰小,具有很高的实用价值。 下载应用纪要请点击: http://www.thermo.com.cn/Resources/201404/3011241425.pdf 关于赛默飞世尔科技 赛默飞世尔科技(纽约证交所代码:TMO)是科学服务领域的世界领导者。公司年销售额170亿美元,在50个国家拥有员工约50,000人。我们的使命是帮助客户使世界更健康、更清洁、更安全。我们的产品和服务帮助客户加速生命科学领域的研究、解决在分析领域所遇到的复杂问题与挑战,促进医疗诊断发展、提高实验室生产力。借助于Thermo Scientific、Life Technologies、Fisher Scientific和Unity? Lab Services四个首要品牌,我们将创新技术、便捷采购方案和实验室运营管理的整体解决方案相结合,为客户、股东和员工创造价值。欲了解更多信息,请浏览公司网站:www.thermofisher.com 赛默飞世尔科技中国赛默飞世尔科技进入中国发展已有30多年,在中国的总部设于上海,并在北京、广州、香港、台湾、成都、沈阳、西安、南京、武汉等地设立了分公司,员工人数超过3800名。我们的产品主要包括分析仪器、实验室设备、试剂、耗材和软件等,提供实验室综合解决方案,为各行各业的客户服务。为了满足中国市场的需求,现有8家工厂分别在上海、北京和苏州运营。我们在全国共设立了6个应用开发中心,将世界级的前沿技术和产品带给国内客户,并提供应用开发与培训等多项服务;位于上海的中国创新中心结合国内市场的需求和国外先进技术,研发适合中国的技术和产品;我们拥有遍布全国的维修服务网点和特别成立的中国技术培训团队,在全国有超过2000名专业人员直接为客户提供服务。我们致力于帮助客户使世界更健康、更清洁、更安全。欲了解更多信息,请登录网站www.thermofisher.cn
Instrument.com.cn Copyright©1999- 2023 ,All Rights Reserved版权所有,未经书面授权,页面内容不得以任何形式进行复制