您好,欢迎访问仪器信息网
注册
安捷伦科技(中国)有限公司

关注

已关注

品牌合作伙伴
钻石23年 钻石

已认证

粉丝量 0

科学仪器行业领军企业科学仪器行业售后服务十佳企业

采购咨询:400-629-8889

售后咨询:400-820-3278

当前位置: 安捷伦 > 解决方案 > 1290 Infinity II 制备型开放式馏分收集器基于时间、峰、质谱触发的馏分收集

1290 Infinity II 制备型开放式馏分收集器基于时间、峰、质谱触发的馏分收集

2018/09/03 14:11

阅读:479

分享:
应用领域:
制药/生物制药
发布时间:
2018/09/03
检测样品:
其他
检测项目:
其他
浏览次数:
479
下载次数:
参考标准:
暂无

方案摘要:

The Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector sets new benchmarks in efficient and flexible fraction collection. The fraction bed can be equipped individually with six containers holding fraction tubes in eight different sizes. Three drawers provide easy access to collected fractions even during a run. Peak- and time-based fraction modes have been extended to eight combined modes, enabling the collection of volume or time slices, and including two recovery collection modes. Trigger combinations of ultraviolet (UV) with mass-selective detection (MSD) signals now include an AND/OR logic that gives extra flexibility for challenging purifications. This Technical Overview provides a deeper insight and typical application examples of the fraction modes, including collection results.

产品配置单:

分析仪器

Agilent 1290 Infinity II 制备型液相色谱

型号: 1290 Infinity II Preparative

产地: 德国

品牌: 安捷伦

面议

参考报价

联系电话

分析软件

Agilent 1290 Infinity II Multisampler

型号: 1290 Infinity II Multisampler

产地: 德国

品牌: 安捷伦

面议

参考报价

联系电话

方案详情:

Abstract 

The Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector sets new benchmarks in efficient and flexible fraction collection. The fraction bed can be equipped individually with six containers holding fraction tubes in eight different sizes. Three drawers provide easy access to collected fractions even during a run. Peak- and time-based fraction modes have been extended to eight combined modes, enabling the collection of volume or time slices, and including two recovery collection modes. Trigger combinations of ultraviolet (UV) with mass-selective detection (MSD) signals now include an AND/OR logic that gives extra flexibility for challenging purifications. This Technical Overview provides a deeper insight and typical application examples of the fraction modes, including collection results.

Introduction

Fraction collection is the key feature that turns an analytical high-performance liquid chromatography (HPLC) system into a purification system. Simple as it may sound, fraction collection in general, and preparative-scale purification in particular, do have challenging facets. Flow rates in preparative-scale HPLC range from 5 up to 100 mL/min or above, generating fraction volumes of below 1 mL up to tens or even hundreds of mL. This demands collection vessels of different sizes, if the fraction collector capacity is to be used in an optimal way. Quick processing of collected fractions (re-analysis, pooling, and solvent evaporation) is desirable, creating the need for an easily accessible fraction bed. 

The Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector1 contains new and improved features that address all of these topics. Fraction containers holding tubes of different diameters (12, 16, 25, 30 mm) and lengths (100 or 150 mm) are optimized to hold fractions of 8 to 78 mL. The fraction bed can be equipped individually with six containers, and holds up to 432 single fractions, or a maximum fraction volume of 5,940 mL. Three drawers separate the fraction bed, and enable the exchange of full drawers even during operation. Only the currently active drawer is locked to prevent spills and sample loss. 

Tubing kits with different inside diameters are available for optimized setup according to the flow rate used. As with the Agilent 1260 Infinity fraction collectors, the 1290 Infinity II Preparative Open-Bed Fraction Collector features a built-in delay sensor, enabling precise calibration of the delay between the detector and the fraction valve without any hardware modifications. 

Along with hardware improvements, the 1290 Infinity II Preparative Open-Bed Fraction Collector offers several enhanced fraction collection modes that combine peak- with time-based collection, and include recovery collections. Fraction collection triggered by a combination of ultraviolet (UV) with mass-selective detection (MSD) signals has also been extended by a third mode, combining the advantages of logical AND/OR connections. This Technical Overview describes the different fraction collection modes available in the 1290 Infinity II Preparative Open-Bed Fraction Collector, and presents typical applications of the feature enhancements.

Conclusion

Besides a larger capacity, and a much more flexible configuration of the fraction bed, the Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector offers new combined fraction modes that are tailored to the demands of different purification challenges. This Technical Overview provides application examples and collection outcomes of these fraction modes, including time-based collection combined with volume slices, peak-based collection combined with time slices, and two recovery collection modes. Peakbased fraction collection is demonstrated with a combination of ultraviolet (UV) and mass-selective detection (MSD) signals, connected by Boolean AND, as well as the novel AND/OR logic


下载本篇解决方案:

资料文件名:
资料大小
下载
5991-7654EN.pdf
1341KB
相关仪器

更多

Agilent 1290 Infinity II 制备型液相色谱

型号:1290 Infinity II Preparative

面议

Agilent 1290 Infinity II Multisampler

型号:1290 Infinity II Multisampler

面议

8850 气相色谱系统

型号:8850

面议

NovoCyte Opteon 光谱流式细胞系统

型号:NovoCyte Opteon

面议

相关方案

应用 QuEChERS 方法结合 Agilent 7000 系列三重四极杆气质联用仪测定甜菜中 的多农药残留

本文介绍了一种用于分析甜菜中 267 种农药的简便、高通量方法。该方法将 QuEChERS 样品前处理方法与 Agilent 7000 系列三重四极杆气质联用系统相结合,并通过基质匹配标样校准进行定量,以降低基质干扰引起的定量偏差。结果表明,该方法在 2–200 μg/kg 的基质加标浓度范围内具有良好的线性关系。绝大部分目标农药化合物的定量限 (LOQ) 低至2 μg/kg,灵敏度高。加标回收率测试表明,在 2、5、10、100 和 200 μg/kg 的加标浓度下,大部分农药化合物的回收率在 80%–120% 的范围内 (n = 5) ,且相对标准偏差 (RSD)低于 10%。该方法适用于对甜菜中的多种农药残留进行常规分析。

食品/农产品

2024/05/13

使用 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪测定脂质纳米颗粒表观 pKa

脂质纳米颗粒 (LNPs) 已被用作各种有效载荷的递送系统。本应用简报展示了 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪用于测定 mRNA LNPs 表观 pKa 的实用性。

制药/生物制药

2024/05/13

使用 ICP-OES 结合自动稀释测定锂盐中的多种元素

使用 Agilent 5800 VDV ICP-OES 和 Agilent ADS 2 自动稀释器自动分析锂离子电池前驱体化学品

能源/新能源

2024/05/13

使用配备高级稀释系统的 ICP-MS 对 高基质样品进行高效分析

在用 Agilent 7850 ICP-MS 分析前,使用 Agilent ADS 2 对沉积物和土壤进行自动稀释

环保

2024/05/13

推荐产品
供应产品

安捷伦科技(中国)有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位