您好,欢迎访问仪器信息网
注册
安捷伦科技(中国)有限公司

关注

已关注

品牌合作伙伴
钻石23年 钻石

已认证

粉丝量 0

科学仪器行业领军企业科学仪器行业售后服务十佳企业

采购咨询:400-629-8889

售后咨询:400-820-3278

当前位置: 安捷伦 > 解决方案 > Enhancing Sensitivity in Analysis of Semivolatile Organic Compounds with the Agilent 8890/5977C GC/MSD

Enhancing Sensitivity in Analysis of Semivolatile Organic Compounds with the Agilent 8890/5977C GC/MSD

2024/02/22 16:21

阅读:66

分享:
应用领域:
环保
发布时间:
2024/02/22
检测样品:
废水
检测项目:
有机污染物
浏览次数:
66
下载次数:
参考标准:
/

方案摘要:

Abstract This application note evaluates the performance of an Agilent 8890/5977C gas chromatography/mass selective detector (GC/MSD) in the analysis of semivolatile organic compounds (SVOCs) at both traditional and enhanced sensitivity levels. The GC/MSD system was initially calibrated with a range of 0.2 to 150 μg/mL with 97% of the 76 evaluated analytes meeting the requirement for average response factor (RF) curve fits. Method modifications to enhance sensitivity were applied to challenge a lower calibration range of 0.01 to 10 μg/mL. Under these amended conditions, 97% of the tested compounds also met or exceeded the United States Environmental Protection Agency (US EPA) Method 8270E criteria for average RF fits. These results demonstrated a potential for lower detection of analytes.

产品配置单:

分析仪器

Agilent 5977C GC/MSD 单四极杆气质联用仪

型号: 5977C GC/MSD

产地: 美国

品牌: 安捷伦

面议

参考报价

联系电话

方案详情:

Introduction

The analysis of semivolatile organic compounds (SVOCs) provides a critical evaluation of our environment for persistent pollutants. The United States Environmental Protection Agency (US EPA) has issued regulations and guidelines in Method 8270E1 for the analysis of these analytes by gas chromatography/mass spectrometry (GC/MS). The analysis of SVOCs as a class comes with challenges and is a reasonable method of testing the performance of a GC/MS platform. The diverse set of analytes include phthalates, phenols, nitrosamines, aromatic nitro compounds, and polynuclear aromatic hydrocarbons (PAHs), among others. These analytes span a wide range of molecular weights and have a wide range of vapor pressures. Some of the analytes are well disposed to analysis by gas chromatography while others present significant challenges relating to stability,reproducibility, and chromatographic integrity.

下载本篇解决方案:

资料文件名:
资料大小
下载
an-gc-msd-svocs-5994-6338en-agilent.pdf
1017KB
相关方案

用于原辅料鉴定的 Agilent Cary 630 FTIR 光谱仪

原辅料鉴定是一项重要的质量保证或安全控制分析措施,广泛用于多种应用和行业中。确认收到的原料身份,有助于避免将受污染、假冒及标签错误的原辅料用于生产流程。分析可确保最终产品符合预期用途所需的质量和纯度。确认最终产品的身份也同样重要,以避免产品出现包装和标签错误。因此,许多行业标准(如世界上多数药典)中都规定了原辅料鉴定这一要求。

制药/生物制药

2024/09/30

分析洗手液中的醇类浓度

醇类定量分析是一种常见的 FTIR 测定用途。使用安捷伦仪器测定校准标样并创建常规分析方法仅需极少专业技能,只需约 15 分钟即可完成。测定每个样品并准确生成有颜色标记的合格/不合格结果用时不到 1 分钟,并可在实验室或现场完成检测。

化妆品

2024/09/30

使用 Agilent Cary 630 ATR-FTIR 光谱仪测定婴儿米粉中的蔗糖浓度

摘要 将纯米粉和裹有蔗糖的婴儿米粉研磨,并用 Agilent Cary 630 傅立叶变换中红外仪 (FTIR) 测定蔗糖、葡萄糖和果糖浓度,并与 HPLC 测量值进行比较。结果表明使用便携式 FTIR 仪器得到的测量结果与 HPLC 测量结果一致,且 Cary 630 适用于对早餐米粉中的糖浓度进行实时分析.

食品/农产品

2024/04/03

安捷伦分子光谱产品在锂离子电池行业中的应用——高效精确,坚固耐用

在 YS/T 582-2013《电池级碳酸锂》、GB/T26008-2010《电池级单水氢氧化锂》等标准中,规定使用分光光度计法检测硫酸根、氯离子、硅等物质。 在 GB/T 19282-2014《六氟磷酸锂产品分析方法》等标准中,规定使用红外光谱等方法进行产品鉴别实验。

石油/化工

2018/08/08

推荐产品
供应产品

安捷伦科技(中国)有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位