核心参数
  • 最高输出能量(毫焦): 90
  • 重复频率(赫兹): 50/100

PhotoSonus X

High Output Power DPSS Tunable Laser for Photoacoustic Imaging
Download
datasheet
  • Integrated DPSS pump laser and OPO system

  • Up to 90 mJ in range 650 – 2600 nm

  • 100 Hz or 50 Hz pulse repetition rate

  • Certification ready

  • Quiet operation < 60 dB

Photosonus X - High Output Power DPSS Tunable Laser for Photoacoustic Imaging

Features & Options

FEATURES

  • Ultra-wide signal tuning range from 650 to 1300 nm

  • Fully motorized wavelength tuning

  • Fast Wavelength Switching

  • Externally triggerable

  • High, up to 90 mJ pulse energy from OPO

  • 100 Hz or 50 Hz pulse repetition rate

  • Certification ready

  • Quiet operation < 60 dB

  • Integrated DPSS pump laser and OPO into a single housing

  • Fiber bundle or fiber

  • Signal and Idler through the same output (optional)

  • Integrated energy meter (optional)

  • Electromechanical output shutter with laser self-test capability

Description

PhotoSonus X is a perfect solution for photoacoustic imaging in pre-clinical and clinical use and when fast sample scanning is required. Having high output energy of up to 90 mJ at the peak, a broad wavelength tuning range from 650 to 2600 nm, high pulse repetition rate up to 100 Hz and fast wavelength switching makes it a perfect photoacoustic imaging source for gaining high-resolution images and ensuring high data acquisition rate. Moreover, being built on a diode pumped solid-state laser platform, PhotoSonus X assures significantly quieter operation (< 60 dB) compared with flash-lamp pumped lasers, which is very beneficial for clinical use.

Diode pumped laser technology and well-engineered system design ensures high reliability and low-cost system operation. PhotoSonus X output can be coupled with almost any type of fiber bundle.

With additional options of an internal energy meter and electromechanical shutter with laser self-test capability, PhotoSonus X can be ready for certification in clinical photoacoustic applications.

Specifications

MODEL 1)PhotoSonus X-50PhotoSonus X-100
OPO
Wavelength range
    Signal650 – 1300 nm
    Idler (optional)1065 – 2600 nm
OPO output pulse energy 2)>90 mJ>50 mJ
Pulse repetition rate 3)50 Hz100 Hz
Scanning step
    Signal0.1 nm
    Idler1 nm
Pulse duration 4)2 – 5 ns
Signal linewidth 5)< 15 cm-1< 10 cm-1
Typical signal beam diameter (1/e²) 6)6 ± 1 mm
Control interfacesLAN, RS232
PHYSICAL CHARACTERISTICS
CoolingClosed loop air-water cooled 7)
Unit size (W × L × H)551 × 400 × 162 mm
Power supply size (W × L × H)483 × 390 × 140 mm
Umbilical length, m0.5 m
OPERATING REQUIREMENTS
Room temperature18 – 27 °C
Relative humidity20 – 80 % (non-condensing)
Power requirements100 – 240 VAC, single phase 50/60 Hz
Power consumption< 2 kW
  1. Due to continuous improvement, all specifications are subject to change without notice. The parameters marked typical are not specifications. They are indications of typical performance and will vary with each unit we manufacture. Unless stated otherwise all specifications are measured at 700 nm.

  2. Measured at the free space output. See tuning curves for typical energy levels at different wavelengths.

  3. Other fixed pulse repetiton rates are available upon request.

  4. FWHM measured with photodiode featuring 1 ns rise time and 300 MHz bandwidth oscilloscope.

  5. At 700 nm or higher wavelength.

  6. Measured at the free space output at 700 nm wavelength.

  7. Using external chiller.

Note: Laser must be connected to the mains electricity all the time. If there will be no mains electricity for longer that 1 hour then laser (system) needs warm up for a few hours before switching on.

Performance & Drawings

Publications

Found total :
7 articles, 7 selected
Application selected :
All Applications
Search :

Hydrophones based on interferometric fiber-optic sensors with applications in photoacoustics

Related applications:  Biomedical Photoacoustic Imaging

Hybrid Photoacoustic/Ultrasound tomograph for real time finger imaging

Related applications:  Biomedical Photoacoustic Imaging

Photoacoustic signal detection using interferometric fiber-optic ultrasound transducers

Related applications:  Biomedical Photoacoustic Imaging

Detecting Rat’s Kidney Inflammation Using Real Time Photoacoustic Tomography

Related applications:  Biomedical Photoacoustic Imaging

Image Enchancement Algorithm of Photoacoustic Tomography using Active Countour Filtering

Related applications:  Biomedical Photoacoustic Imaging

A Custom Developed Linear Array Photoacoustic Tomography for Noninvasive Medical Imaging

Related applications:  Biomedical Photoacoustic Imaging

Enhancement of objects in photoacoustic tomography using selective filtering

Related applications:  Biomedical Photoacoustic Imaging

Ordering information


售后服务承诺

保修期: 1年

是否可延长保修期:

现场技术咨询:

免费培训: 一人次

免费仪器保养: 质保期内一次

保内维修承诺: 全天候电话邮件微信远程连接支援服务

报修承诺: 一周内到达用户现场开始维修

用户评论
暂无评论
问商家

Ekspla激光产品PhotoSonus X的工作原理介绍

激光产品PhotoSonus X的使用方法?

EksplaPhotoSonus X多少钱一台?

激光产品PhotoSonus X可以检测什么?

激光产品PhotoSonus X使用的注意事项?

EksplaPhotoSonus X的说明书有吗?

Ekspla激光产品PhotoSonus X的操作规程有吗?

Ekspla激光产品PhotoSonus X报价含票含运吗?

EksplaPhotoSonus X有现货吗?

Ekspla PhotoSonus X 型用于光声成像的高功率DPSS可调谐激光器信息由北京欧兰科技发展有限公司为您提供,如您想了解更多关于Ekspla PhotoSonus X 型用于光声成像的高功率DPSS可调谐激光器报价、型号、参数等信息,欢迎来电或留言咨询。
移动端

仪器信息网App

返回顶部
仪器对比

最多添加5台