您好,欢迎访问仪器信息网
注册
JASCO 公司

关注

已关注

金牌7年 金牌

已认证

粉丝量 0

400-827-8006

仪器信息网认证电话,请放心拨打

当前位置: JASCO > 解决方案 > 用汞灯365 nm测量氢溴酸右美沙芬的旋光

用汞灯365 nm测量氢溴酸右美沙芬的旋光

2019/12/22 14:18

阅读:227

分享:
应用领域:
制药/生物制药
发布时间:
2019/12/22
检测样品:
化药制剂
检测项目:
理化性质
浏览次数:
227
下载次数:
参考标准:

方案摘要:

Optical rotation of Dextromethorphan Hydrobromide in accordance with the U.S. Pharmacopeia, is requested to be measured at 325 nm, however there is no emission line of 325 nm available in the polarimeter using Na lamp or Hg lamp as light source. Therefore, for the measurement of optical rotation of Dextromethorphan Hydrobromide, a polarimeter with halogen lamp as a light source and interference filter (325 nm) has been usually used, but as shown in Fig. 1, the optical rotatory dispersion (ORD) spectrum, there is a very steep slope in the short wavelength range near 325 nm, where even a very small error in the wavelength of interference filter may cause a very large error in the optical rotation measurement, which will makes the accurate measurements very difficult. On the other hand, if the measurement by using 365nm is allowed, since no wavelength error is expected, the measurement of optical rotation can be implemented with much higher accuracy. In this experiment, Dextromethorphan Hydrobromide was measured using polarimeter with Hg lamp (365 nm), polarimeter with Halogen lamp and interference filter (325 nm) and polarimeter with ORD attachment.

产品配置单:

分析仪器

JASCO P-2000旋光仪

型号: P-2000

产地: 日本

品牌: 日本分光计器

¥15万 - 20万

参考报价

联系电话

方案详情:

Optical rotation of Dextromethorphan Hydrobromide in accordance with the U.S. Pharmacopeia, is requested to be measured at 325 nm, however there is no emission line of 325 nm available in the polarimeter using Na lamp or Hg lamp as light source. Therefore, for the measurement of optical rotation of Dextromethorphan Hydrobromide, a polarimeter with halogen lamp as a light source and interference filter (325 nm) has been usually used, but as shown in Fig. 1, the optical rotatory dispersion (ORD) spectrum, there is a very steep slope in the short wavelength range near 325 nm, where even a very small error in the wavelength of interference filter may cause a very large error in the optical rotation measurement, which will makes the accurate measurements very difficult. On the other hand, if the measurement by using 365nm is allowed, since no wavelength error is expected, the measurement of optical rotation can be implemented with much higher accuracy. In this experiment, Dextromethorphan Hydrobromide was measured using polarimeter with Hg lamp (365 nm), polarimeter with Halogen lamp and interference filter (325 nm) and polarimeter with ORD attachment.

下载本篇解决方案:

资料文件名:
资料大小
下载
用汞灯365nm发射线测量氢溴酸右美沙芬的旋光.pdf
146KB
相关仪器

更多

JASCO P-2000旋光仪

型号:P-2000

¥15万 - 20万

圆二色光谱测样服务

型号:圆二色光谱测试

面议

日本分光(JASCO)荧光光谱仪 FP-8050系列

型号:FP-8050系列

¥20万 - 30万

相关方案

使用CD分析安非他命及其对映异构体

鉴定合成副产物和确定活性物质的对映体组成以及制剂中存在的杂质,是法医和药理学分析的重要目的。 这对于比较和评价生产方法也是有用的。 在本应用中,我们将展示CD在对映体组成测定中的适用性。

制药/生物制药

2021/01/21

使用圆二色自动滴定装置分析人血清白蛋白与水杨酸相互作用

This application notes demonstrates the use of the J-1500 CD spectrometer and ATS-530 automatic titrator to monitor the interaction of HSA titrated with 3,5-diiodosalicylic acid. While 3,5-diiodosalicylic acid is achiral, its interaction with chiral HSA induces circular dichroism.

医疗/卫生

2020/09/09

使用停留圆二色光谱研究三氟乙醇对刀豆蛋白A的展开

This application note demonstrates that stopped-flow CD measurements can be used to measure the protein unfolding processes, analyze the secondary structure changes, and obtain reaction rate constants

生物产业

2020/04/08

使用微量样品盘测量CD光谱

这个应用文章主要将演示缓解和一滴血微量试样光盘通过测量的效率四个蛋白的CD光谱。

生物产业

2020/02/09

推荐产品
供应产品

JASCO 公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: JASCO 公司

公司地址: 北京市怀柔区雁栖镇京加路18号 联系人: JASCO 邮编: 101407 联系电话: 400-827-8006

仪器信息网APP

展位手机站