当前位置: 联和层析 > 解决方案 > Gas chromatographic/chemiluminescence detection (thermal energy analyzer-nitrogen mode) method for the determination of dibutylamine in hams.

Gas chromatographic/chemiluminescence detection (thermal energy analyzer-nitrogen mode) method for the determination of dibutylamine in hams.

2007/06/07 09:04

阅读:1100

分享:
应用领域:
发布时间:
2007/06/07
检测样品:
检测项目:
浏览次数:
1100
下载次数:
5
参考标准:

方案摘要:

A gas chromatographic (GC) procedure is described for the determination of dibutylamine (DBA) in ham at less than 1 ppm. Sample is extracted with 0.5N HCl, centrifuged, made basic, and then extracted with isopropyl alcohol. Final determination is by GC/thermal energy analysis in the nitrogen mode. Six replicate analyses of ham fortified with 0.5 ppm DBA gave a recovery of 90.2 +/- 3.4%. Over a range of 0.5 to 3.0 ppm DBA, the repeatability was 0.07 ppm, and the coefficient of variation was 6.07%. Limit of detection was 0.1 ppm. Effectiveness of the procedure was demonstrated on selected ham samples.

产品配置单:

分析软件

英国CSI TEA610 热能分析仪(原Thermo Electron厂牌)

型号: TEA 610

产地: 英国

品牌: CSI

面议

参考报价

联系电话

相关方案

NanoBrook产品应用-12-ZetaPALS

文献名: Structural, morphological and optical properties of Bi NPs obtained by laser ablation and their selective detection of L-cysteine 作者: Ramon Gabriel Teixeira Rosaa, Celso de Araujo Duartea , Wido Herwig Schreinera, Ney Pereira Mattoso Filhoa, Arandi Ginane Bezerra Jr.b, Andersson Barisonc, Fernanda Maria Marins Ocamposc a Departamento de Física, Universidade Federal do Paraná Centro Politécnico, CP 19044, 81531-990 Curitiba (PR), Brazil b Departamento Acadêmico de Física, Universidade Tecnológica Federal do Paraná, 80230-901 Curitiba (PR), Brazil c Departamento de Química, Universidade Federal do Paraná Centro Politécnico, CP 19081, 81531-990 Curitiba (PR), Brazil 摘要:In the present work we show the results of the investigation of the properties of bismuth nanoparticles (NPs) obtained by the laser ablation in water. The samples were characterized by various techniques: UV/vis spectroscopy, dynamic light scattering, transmission electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, nuclear magnetic resonance and zeta potential. The NPs were metallic and surface oxidated, exhibiting absorption peak at 257 nm due to the surface plasmon resonance. The interaction between the NPs and various amino acids was studied and revealed a selective sensibility to cysteine on a range of concentration from 80 to 720 μM, which we attribute to a dimerization of cysteine to cystine probably complexed to the nanoparticle surface by electrostatic interactions, leading to the modification of the NP absorption spectrum. 关键词:Bismuth; Nanoparticles; Laser ablation; Cysteine

2015/04/16

中药提取类产品解决方案

从中药中提取分离化合物,第一步需要将中药材中的成分用有机溶剂提取出来,包括常规的有机溶剂浸泡,超声提取,超临界提取和加速溶剂萃取(Aseeker-600型加速溶剂萃取仪)等,得到一份总提物。

制药/生物制药

2021/01/04

4D-脂质组学高通量工作流程

Lipid profiling from complex lipid extracts can be a challenging and time consuming task. The high complexity of samples and co-elution of isobaric or isomeric compounds complicate the confident annotation of lipids. The presented 4D-Lipidomics workflow simplifies and streamlines the annotation and validation process using mobility-enhanced MS data.

医疗/卫生

2021/03/05

称量仪器的校准

当称量仪器用于与质量控制相关的测量时,校准是必须定期执行的关键操作之一。国际上有许多标准规范都有这方面的要求,例如ISO9001、GMP法规以及与食品安全相关的一些标准。然而关于校准的定义、实施和校准的具体操作在全球范围内并没有一个完全统一的标准。在此,我们首先需要了解一下什么是校准,以及与调整和检定的区别。