您好,欢迎访问仪器信息网
注册
安捷伦科技(中国)有限公司

关注

已关注

品牌合作伙伴
钻石23年 钻石

已认证

粉丝量 0

科学仪器行业领军企业科学仪器行业售后服务十佳企业

采购咨询:400-629-8889

售后咨询:400-820-3278

当前位置: 安捷伦 > 解决方案 > Dynamic MRM/Scan Mode: Adding More Confidence to Sensitive Quantitation in Complex Foods by Triple Quadrupole GC/MS (GC/TQ)

Dynamic MRM/Scan Mode: Adding More Confidence to Sensitive Quantitation in Complex Foods by Triple Quadrupole GC/MS (GC/TQ)

2024/02/26 16:20

阅读:24

分享:
应用领域:
食品/农产品
发布时间:
2024/02/26
检测样品:
酱腌菜
检测项目:
/
浏览次数:
24
下载次数:
参考标准:
/

方案摘要:

Abstract This application note describes the use of the novel simultaneous dynamic multiple reaction monitoring (dMRM) and scan (dMRM/scan) data acquisition mode for triple quadrupole gas chromatography mass spectrometry (GC/TQ) analysis of pesticides in challenging food matrices. The simultaneous dMRM/scan capability enables identification of the unknown compounds and retrospective analysis, while maintaining sensitivity and dynamic range of the method comparable to a conventional dMRM analysis. Additionally, scan data enables more confidence in compound identification by library spectrum matching. Finally, the full scan data allow the analyst to evaluate the sample matrix to ensure the most efficient performance of the GC/TQ system. This work demonstrates the application of dMRM/scan to the analysis of extracts, using Agilent QuEChERS sample preparation, of spinach, walnut, and cayenne pepper spiked with over 200 pesticides. The calibration results and method sensitivity for 203 evaluated compounds were comparable to results observed with conventional dMRM data acquisition mode with the Agilent 8890/7000E GC/TQ and the Agilent 8890/7010C GC/TQ. The unknown identification workflow based on the spectral library matching using a retention time locked library was carried out with Agilent MassHunter Unknowns Analysis. Many of the compounds with the established maximum residue limits (MRLs) were identified with full scan data at concentrations below their MRLs even in the challenging cayenne pepper extract

产品配置单:

分析仪器

Agilent 7000E 三重四极杆气质联用系统

型号: 7000E GC/MS

产地: 美国

品牌: 安捷伦

面议

参考报价

联系电话

方案详情:

Introduction


Concern about trace-level food contaminants is driving the demand for robust, rapid, and reliable methods for identification and quantitation of chemical residues and contaminants in food matrices. Usually, the detection methods such as triple quadrupole GC/MS and triple quadrupole LC/MS are aimed at a specific list of targets that are commonly found in food samples. These methods can be effective but may overlook any residues that are not specifically targeted. The approach to overcome this challenge is to perform untargeted screening of the sample intending to find as many compounds of concern as possible and allowing for retrospective analysis. Untargeted screening can be accomplished by analyzing the sample in full scan data acquisition mode.1,2 However, targeted triple quadrupole GC/MS (GC/TQ) analysis has an advantage of higher sensitivity and selectivity for the target analytes when compared to full scan analysis. The novel simultaneous dynamic MRM and scan (dMRM/scan) allows for acquiring both targeted dMRM GC/TQ data for target quantitation as well as full scan data for unknowns screening. Also, the simultaneous dynamic MRM and scan (dMRM/scan) deliver confident identification based on spectral library matching


下载本篇解决方案:

资料文件名:
资料大小
下载
an-dmrm-scan-gc-ms-ms-pesticide-analysis-5994-4966en-agilent.pdf
2861KB
相关仪器

更多

相关方案

应用 QuEChERS 方法结合 Agilent 7000 系列三重四极杆气质联用仪测定甜菜中 的多农药残留

本文介绍了一种用于分析甜菜中 267 种农药的简便、高通量方法。该方法将 QuEChERS 样品前处理方法与 Agilent 7000 系列三重四极杆气质联用系统相结合,并通过基质匹配标样校准进行定量,以降低基质干扰引起的定量偏差。结果表明,该方法在 2–200 μg/kg 的基质加标浓度范围内具有良好的线性关系。绝大部分目标农药化合物的定量限 (LOQ) 低至2 μg/kg,灵敏度高。加标回收率测试表明,在 2、5、10、100 和 200 μg/kg 的加标浓度下,大部分农药化合物的回收率在 80%–120% 的范围内 (n = 5) ,且相对标准偏差 (RSD)低于 10%。该方法适用于对甜菜中的多种农药残留进行常规分析。

食品/农产品

2024/05/13

使用 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪测定脂质纳米颗粒表观 pKa

脂质纳米颗粒 (LNPs) 已被用作各种有效载荷的递送系统。本应用简报展示了 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪用于测定 mRNA LNPs 表观 pKa 的实用性。

制药/生物制药

2024/05/13

使用 ICP-OES 结合自动稀释测定锂盐中的多种元素

使用 Agilent 5800 VDV ICP-OES 和 Agilent ADS 2 自动稀释器自动分析锂离子电池前驱体化学品

能源/新能源

2024/05/13

使用配备高级稀释系统的 ICP-MS 对 高基质样品进行高效分析

在用 Agilent 7850 ICP-MS 分析前,使用 Agilent ADS 2 对沉积物和土壤进行自动稀释

环保

2024/05/13

推荐产品
供应产品

安捷伦科技(中国)有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位