Accelerated lifetime testing with real-time Early Maintenance Feedback (EMF) diagnostic monitoring on the 6475 triple quadrupole LC/MS

2023/08/15 15:02

阅读:101

分享:
应用领域:
石油/化工
发布时间:
2023/08/15
检测样品:
天然橡胶
检测项目:
有害物质
浏览次数:
101
下载次数:
参考标准:
/

方案摘要:

Triple quadrupole LC/MS systems have become widely accepted as a platform for targeted, large-batch, sample analysis on a day-to-day basis. A primary concern for routine/targeted analysis is instrument stability; which can vary over time due to the soiling of crucial ion optics components. While incorporating an internal standard and measuring abundance ratio may help alleviate signal drift from a data-analysis standpoint, it does not give key indications to the quality of the instrument’s health.

产品配置单:

分析仪器

Agilent 6475 三重四极杆液质联用仪

型号: 6475

产地: 新加坡

品牌: 安捷伦

面议

参考报价

联系电话

方案详情:

To help alleviate concerns on instrument health and longevity, the new Agilent 6475 triple quadrupole LC/MS system was designed with onboard intelligence that actively reports on the instrument health and status through Early Maintenance Feedback (EMF).


EMF reports various aspects pertaining to instrument maintenance such as “last tuned”, number of samples injected, number of diverter valve switches, last rough pump oil change, last gas filter change, and real time reports on detector health, nebulizer blockage, ion injector blockage, and spray stability status.


Here we present a use case to trigger Early Maintenance Feedback (EMF) events to simulate heavy instrument use through 10,000 sample injections of spiked bovine urine. The sample matrix was specifically chosen due the challenging endogenous components that may cause measurement issues (salts, metabolites, fats, proteins, etc…).


As this is not a true analytical method, the intention of this poster is primarily to stress the Early Maintenance Feedback mechanisms, test the instrument’s

response to heavy matrix accumulation, stability of tune parameters, and recovery of instrument tuning if out of spec.


下载本篇解决方案:

资料文件名:
资料大小
下载
ps-6475-emf-asms-2022-tp327-en-agilent.pdf
605KB
相关方案

应用 QuEChERS 方法结合 Agilent 7000 系列三重四极杆气质联用仪测定甜菜中 的多农药残留

本文介绍了一种用于分析甜菜中 267 种农药的简便、高通量方法。该方法将 QuEChERS 样品前处理方法与 Agilent 7000 系列三重四极杆气质联用系统相结合,并通过基质匹配标样校准进行定量,以降低基质干扰引起的定量偏差。结果表明,该方法在 2–200 μg/kg 的基质加标浓度范围内具有良好的线性关系。绝大部分目标农药化合物的定量限 (LOQ) 低至2 μg/kg,灵敏度高。加标回收率测试表明,在 2、5、10、100 和 200 μg/kg 的加标浓度下,大部分农药化合物的回收率在 80%–120% 的范围内 (n = 5) ,且相对标准偏差 (RSD)低于 10%。该方法适用于对甜菜中的多种农药残留进行常规分析。

食品/农产品

2024/05/13

使用 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪测定脂质纳米颗粒表观 pKa

脂质纳米颗粒 (LNPs) 已被用作各种有效载荷的递送系统。本应用简报展示了 Agilent BioTek Synergy Neo2 Hybrid 多功能微孔板检测仪用于测定 mRNA LNPs 表观 pKa 的实用性。

制药/生物制药

2024/05/13

使用 ICP-OES 结合自动稀释测定锂盐中的多种元素

使用 Agilent 5800 VDV ICP-OES 和 Agilent ADS 2 自动稀释器自动分析锂离子电池前驱体化学品

能源/新能源

2024/05/13

使用配备高级稀释系统的 ICP-MS 对 高基质样品进行高效分析

在用 Agilent 7850 ICP-MS 分析前,使用 Agilent ADS 2 对沉积物和土壤进行自动稀释

环保

2024/05/13

推荐产品
供应产品

安捷伦科技(中国)有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位