活体转基因--钳状电极用于体内药物/基因/蛋白质传递及基因治疗电极.
活体转基因--钳状电极Tweezertrodes是一种可复用的小钳状电极,主要用于体内的药物或基因的传递。电极是一个标准的11.5厘米的小钳子,其尖部为嵌入的不锈钢圆盘状电极,两盘的间隙可调至2厘米,并有一个阳极指示器。
活体转基因--钳状电极Tweezertrodes电极有两种规格,45-0118为直径:7mm的电极盘,45-0119为直径:10mm的电极盘
当把感兴趣的分子注射到体内后,用电极盘夹住相关组织,然后给出电脉冲,使孔道开始形成,将分子整合到直接与电极盘接触的组织细胞内。

Tweezertrodes are reusable, tweezer-style in vivo electrodes fordrug or gene delivery in animals. Tweezertrodes consist of astandard 11.5 cm tweezer that has been modified with stainlesssteel circular or disk electrodes at the tip. The gap between theelectrode disks may be adjusted from under 1 mm to over 2 cm.Tweezertrodes come in two models. Model 520 has an electrode diskdiameter of 7 mm and Model 522 has a diameter of 10 mm.Tweezertrodes may be cleaned with a mild detergent and sterilizedwith ethanol or ethylene oxide. These electrodes are connected to apulse generator with the Model 524 Connection Cable, and arecompatible with most BTX Electroporation System
Applications

Tweezertrodes may be used for many in vivo applications, includinggene and drug delivery. Following localized or systemic injectionof the molecule of interest, the Tweezertrode electrode disks areused to grasp the tissue of interest. An electroporation pulse isthen given, initiating pore formation and incorporation of themolecule into the cells of the tissue in direct contact with theelectrode disks. Suzuki et al. used Tweezertrodes to deliver aGreen Fluorescent Protein (GFP) gene into rat liver. The authorsdemonstrated successful gene transfer and expression in situ.1,2Saito and Nakatsuji used a similar electrode to introduce plasmidDNA during ex-utero and in-utero electroporation.7 Sato et al. usedthe Tweezertrode with the T820 to introduce EGFP expressing plasmidin mouse testis.8 Tweezertrodes complement BTX Genetrode Models508, 510, Caliper Electrode Models 384 and 384L, 2-Needle ArrayModels 530 and 532 as the newest addition to our in vivo electrodeline. The Tweezertrodes can be used to reproduce applicationsrequiring the caliper electrodes, including gene therapy,transdermal drug delivery and electroporation therapy.3,4,5,6

Technical Specifications


Standard Capabilities
Voltage Range: 0V - 200V (Do not use AC current)
Pulse Length Range: 1 µsec - 200 msec
Physical Characteristics
Model 520
Tweezertrode Length: 11.5 cm
Electrode Diameter: 7 mm
Electrode Material: Stainless steel
Model 522
Tweezertrode Length: 11.5 cm
Electrode Diameter: 10 mm
Electrode Material: Stainless steel
Generator Compatibility ECM T820, 630, 830, 2001

Ordering Information

System Model Available Configurations
520 Tweezertrode 520
Tweezer Electrode with stainless steel plated 7 mm diameterelectrode disk for in vivo applications

523 Tweezertrode 523
Tweezer Electrode with stainless steel plated 10mm diameterelectrode disk for in vivo applications

Accessory Model Description
524 Tweezertrode Connection Cable

References
Suzuki et al., Direct Gene Transfer into Rat Liver Cells by in vivoElectroporation, FEBS Letters, 425: 436-440 (1998)
BTX Electroporation Protocol PR0363 (1998)
Zhang et al., In vivo transdermal delivery of large molecules bypressure-mediated electroincorporation and electroporation: a novelmethod for drug and gene delivery, Bioelectrochemistry andBioenergetics, 42: 283-292 (1997)
Dev, Giordano and Brown, In vivo delivery of gene to rabbit carotidartery by electroporation, Third U.S. / Japan Symposium on DrugDelivery Systems (Abstr.), 38 (1995)
Dev, Killing cancer cells with a combination of pulsed electricfields and chemotherapeutic agents, Cancer Watch, 3: 12-14 (1994)
BTX Electroporation Therapy Protocols ECT001-ECT005 (1995)
Saito and Nakatsuji, Developmental Biology, 240: 237-246 (2001)
Sato et al., Molecular Reproduction and Development, 61: 49-56(2002)

相关方案

  • Lack of TCF2vHNF1 in mice leads to pancreas agenesis C. Haumaitre*, E. Barbacci*, M. Jenny?, M. O. Ott*, G. Gradwohl?,and S. Cereghini*? *Biologie du De′ veloppement, Unite′ Mixte de Recherche 7622,Centre National de la Recherche Scientifique, Universite′ Pierre etMarie Curie, 9 Quai St. Bernard Ba t C, 75005 Paris, France; and ?Institut National de laSante′ et de la Recherche Me′ dicale U381, 3 Avenue Molie` re,67200 Strasbourg, France Edited by Kathryn V. Anderson, Sloan–Kettering Institute, New York,NY, and approved December 20, 2004 (received for review August 6,2004) Heterozygous mutations in the human POU-homeobox TCF2

    生物产业 2014-09-23

  • Lack of TCF2vHNF1 in mice leads to pancreas agenesis C. Haumaitre*, E. Barbacci*, M. Jenny?, M. O. Ott*, G. Gradwohl?,and S. Cereghini*? *Biologie du De′ veloppement, Unite′ Mixte de Recherche 7622,Centre National de la Recherche Scientifique, Universite′ Pierre etMarie Curie, 9 Quai St. Bernard Ba t C, 75005 Paris, France; and ?Institut National de laSante′ et de la Recherche Me′ dicale U381, 3 Avenue Molie` re,67200 Strasbourg, France Edited by Kathryn V. Anderson, Sloan–Kettering Institute, New York,NY, and approved December 20, 2004 (received for review August 6,2004) Heterozygous mutations in the human POU-homeobox TCF2

    生物产业 2014-09-23

售后服务承诺

保修期: 1年

是否可延长保修期:

现场技术咨询:

免费培训: 1人次技术中心培训

免费仪器保养: 3月一次

保内维修承诺: 一年内免费更换零件

报修承诺: 3天内到达现场维修

用户评论
暂无评论
问商家

BTX 细胞融合仪BTX MODEL 524的工作原理介绍

细胞融合仪BTX MODEL 524的使用方法?

BTX BTX MODEL 524多少钱一台?

细胞融合仪BTX MODEL 524可以检测什么?

细胞融合仪BTX MODEL 524使用的注意事项?

BTX BTX MODEL 524的说明书有吗?

BTX 细胞融合仪BTX MODEL 524的操作规程有吗?

BTX 细胞融合仪BTX MODEL 524报价含票含运吗?

BTX BTX MODEL 524有现货吗?

活体转基因--钳状电极信息由香港友诚生物科技有限公司为您提供,如您想了解更多关于活体转基因--钳状电极报价、型号、参数等信息,欢迎来电或留言咨询。
移动端

仪器信息网App

返回顶部
仪器对比

最多添加5台