法国TECHNIX高压充电电源,主要作为高压电容器以及MARX发生器等设备的充电电源。
High Voltage CCR models are designed to charge high voltage capacitors and marx generators
All the numerous advantages of compactness, robustness, reliability, and saving offered with the double resonance technology are already available on these models which constitute the low end range.
Five series of power are offered: 300 W, 600 W, 1200 W, 1500 W and 3000 W. These generators are all based on a 19" rack presentation with a 3U or 5U height depending on voltage and power proposed.
Using a modular design, our products integrate the latest technology components. Above 20 kV, High Voltage subassembly is wrapped in resin or merged in a tank containing mineral oil.
-
Voltage & Current Outputs continuously adjustable from 0 to full scale
-
Customized V and C full scales* with no extracost
-
Total protection against arcs, overloads and short circuits
-
Over Temperature protection
-
Compact design
-
Double Resonance Technology (ZVC)
-
V & C Setting and Monitoring from front panel or Remote
-
Automatic crossover
-
Limited inrush current
-
Remote, Inhibit & Interlock functions
-
3 ½ digit displays with polarity display
-
Safety switch key
-
Warranty: 2 years
* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 3 750 V generator based on 1 500 W model. In this case, you will get an Output Voltage adjustable from 0 to 3 750 V and an Output Current from 0 to 400 mA.
-
Output Voltage and Output Current:
Both Voltage Output and Current Output are continuously adjustable from 0 to 100 % (full scale).
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V
-
Reproducibilty (pulse to pulse voltage variation):
Load Regulation: ± 0.25 % (Frequency < 10 Hz)
Line Regulation: ± 0.1 % ( for Main Voltage ± 10 %)
-
Current regulation:
Load Regulation: ± 0.05 % (for 0 - 100 % load change)
Line Regulation: ± 0.05 % (for Main Voltage ± 10 %)
-
Voltage Holding:
0.25 % p-p (better on request)
-
Stored Energy:
0.2J/kJ
-
Protections:
Against short circuit & HV arc to ground
Shutdown on Overtemperature, & open interlock
-
Stability (after one hour warm-up):
0.01 % / hour, 0.03 % / 8 hoursof operating with constant load and ambient temperature.
-
Temperature Coefficient:
100 ppm/°C
-
Operating Temperature:
from 0 to 40°C
-
Efficiency:
> 88 % full load
-
Air Cooling
-
Mains Voltage:
170 to 255 VAC ± 10 % 47 – 63 Hz + Earth up to 600 J/s
400 VAC ± 10 % 47 – 63 Hz 3 Phases + Earth from 750 J/s
(other main voltage on request)
-
Inrush current:
limited to full power operating current
-
Power factor:
> 0.98
-
Calibration:
with probes periodically approved by Authorized
Measurement Laboratories