瑞典INOR温度变送器IPAQ-R330 is a universal, isolated, temperature transmitter with additional
voltage and resistance input. Its robust design and high quality gives
excellent performance and accuracy also under harsh conditions.
IPAQ R330 supports communication via NFC® (Near-field communication)
and Bluetooth® which makes it possible to configure and monitor the
transmitter remotely.
瑞典INOR温度变送器IPAQ-R330技术参数:
Input RTD 2-, 3-, 4-wire connection
Pt100 (α =0.00385) -200 to +850 °C / -328 to +1562 °F
PtX 10 ≤ X ≤ 1000 (α =0.00385) Upper range depending on X-value
Pt100 (α =0.003916) -200 to +850 °C / -328 to +1562 °F
Ni1001), Ni1202) -60 to +250 °C / -76 to +482 °F
Ni10001) -50 to +180 °C / -58 to +356 °F
Cu103) -50 to +200 °C / -58 to +392 °F
Input Resistance / potentiometer 0 to 10000 Ω / 100 to 10000 Ω
Input Thermocouples Types B, C, D, E, J, K, N, R, S, T
Input mV -10 to +1000 mV
Sensor failure Upscale (≥21.0 mA) or downscale (≤3.6 mA) action
Adjustments - Zero Any value within range limits
Adjustments - Minimum spans
Pt100, Pt1000, Ni100, Ni1000 10 °C / 18 °F
Potentiometer 10 Ω
T/C, mV 2 mV
Output 4-20 / 20-4 mA, temperature linear
Operating temperature -40 to +85 °C / -40 to +185 °F
Galvanic isolation 1500 VAC, 1 min
Power supply IPAQ R330 8.0...36.0 VDC
IPAQ R330X 8.0...30.0 VDC
Intrinsic safety
IPAQ R330X ATEX: II 1 G Ex ia IIC T6…T4 Ga4)
IPAQ R330X IECEx: Ex ia IIC T6…T4 Ga4)
IPAQ R330X cFMus: IS CL I Div 1 GP A-D, T6...T4
Cl I Zn 0 AEx/Ex ia IIC T6...T4 Ga4)
Typical accuracy ±0.08°C or ±0.08% of span
Mounting Rail acc. to DIN EN 50022, 35 mm
1) DIN 43760, 2) Edison No.7, 3) Edison No.15 4) For Tambient, see the manual
• High accuracy and long term stability
• 50-point Customized Linearization and Callendar-Van Dusen
• Accepts RTD, T/C, mV and Ω
• Sensor error and system (sensor/transmitter) error correction for
highest total accuracy
• Low temperature drift
• Configuration via USB, without external power
• Runtime counter - hour counter for elapsed operational time
• Rugged design tested for 5 g vibrations
• High security - Password protection and date of changes logged