technical requirements:
In 01, the input voltage: AC 220 V
In 02, the output voltage: AC 0--50 KV;
DC 0 - 50 KV
03, electrical capacity: 3KVA
In 04, high grade: 0-10KV, 0--50KV,
In 05, 100V/S 200V/S 500 V/S pressure rate: 1000 V/S 2000V/S 5000V/S
( Note: meet the standard requirements and can be based on user needs to set different pressurization rate )
06, test method:
DC test: 1, 2, 3 speed boost pressure gradient, pressure test
AC test: 1, 2, 3 speed boost pressure gradient, pressure test
In 07, the dielectric strength tester, test media: air, test oil
In 08, the installation of high sensitivity over current protection device to ensure that the sample breakdown in 0.05S to cut off the power supply.
09, adopts an intelligent integrated circuit speed boost.
10, support a short time short-circuit test requirements.
11, voltage test accuracy:≤ 1%.
In 12, the test voltage is continuous and adjustable: 0--50KV.
13, the current can be collected to level mA.
14, issued by the country one class unit of measurement calibration verification certificate issued or customers designated units of measurement certificate.
15, power: 220V ± 10% single-phase AC voltage and 50Hz±1% frequencies.
16, current and voltage stability: the external power supply voltage fluctuation 10%