您好,欢迎访问仪器信息网
注册
上海漾盟仪器有限公司

关注

已关注

已认证

粉丝量 0

当前位置: ICM > 解决方案 > 用SPEX冷凍研磨机研磨人类牙齿

用SPEX冷凍研磨机研磨人类牙齿

2011/09/27 09:55

阅读:500

分享:
应用领域:
发布时间:
2011/09/27
检测样品:
检测项目:
浏览次数:
500
下载次数:
3
参考标准:

方案摘要:

• JAAS www.rsc.org/jaas Dario Santos Junior, Fernando Barbosa Junior, Samuel Simiao de Souza and Francisco Jose Krug Cryogenic sample grinding for copper, lead and manganese determination in human teeth by slurry sampling GFAAS 用SPEX冷凍研磨機研磨人类牙齿而後用悬浮液进样石墨炉原子吸收法測試铜、 铅、锰 A simple method is proposed for copper, lead and manganese determination in deciduous teeth by graphite furnace atomic absorption spectrometry (GFAAS) using slurry sampling introduction and cryogenic sample preparation. Teeth samples were ground in a cryogenic mill in two steps: pre-cooling (5 min) and cryogenic grinding (2 min) in liquid nitrogen. After grinding, 90% of the sample particles were lower than 150 mm. The minimum mass necessary for slurry preparation as an indicator of sub-sample homogeneity was evaluated by weighting masses between 5 and 20 mg directly in autosampler cups, followed by addition of 1 mL of a solution containing 0.04% Triton1 X-100 and 0.2% v/v HNO3. Samples (20 mL) were sonicated during 20 s, before delivering into a W–Rh coated platform. Detection limits based on integrated absorbance were 34.0 ng g21 Pb, 7.4 ng g21 Mn and 18.0 ng g21 Cu for 2% m/v slurries. W–Rh permanent modifier permitted calibration against aqueous standards. The Certified Reference Material (H-5 animal bone) from the International Agency of Atomic Energy (IAEA) was analyzed to determine lead for method validation. For copper, lead and manganese, 12 human teeth samples were analyzed using the proposed method with calibration against aqueous solution and using a comparative Pd/Mg method with the same digested samples, and standard addition calibration, with no statistical difference at 95% level on applying the t-test. Dario Santos Junior, Fernando Barbosa Junior, Samuel Simiao de Souza and Francisco Jose Krug Cryogenic sample grinding for copper, lead and manganese determination in human teeth by slurry sampling GFAAS 用SPEX冷凍研磨機研磨人类牙齿而後用悬浮液进样石墨炉原子吸收法測試铜、 铅、锰
相关仪器

更多

BioDrop 微量比色皿

型号:BioDrop125/500

¥7万 - 10万

BioDrop TOUCH 超微量分光光度计

型号:BioDrop TOUCH

¥7万 - 10万

BioDrop μLITE 超微量分光光度计

型号:BioDrop μLITE

¥7万 - 10万

BioDrop DUO 多功能超微量分光光度计

型号:BioDrop DUO

¥10万 - 15万

相关方案

qTOWER3G上进行新型冠状病毒SARS-COV-2的qPCR检测

市面上有众多的新冠病毒qPCR检测试剂盒,本应用方案采用韩国Seegene公司的AllplexTM 2019-nCoV检测试剂盒在耶拿荧光定量PCR仪 qTOWER³G上进行样品检测,获得符合预期的结果。

生物产业

2020/10/20

方向效应:解决食品中金属检测的挑战难题

金属检测技术的局限性之一是对于像电线和大头针这样相对比较小的、长条形金属异物就很难检测出来。这些类型的污染物通常表现出“方向效应”,即金属探测器所检测到的信号很大程度上取决于污染物与探测孔的方向关系。方向效应给金属检测系统带来了挑战——这一挑战乍一看并不是那么严重,但事实上它可能会给消费者的安全以及品牌声誉带来严重的影响和危害。

食品/农产品

2021/01/19

基于紫外分光光度法的水中油测试方法

矿物油组成中的共轭体系物质在紫外光区有较强的吸收,依据朗博 - 比尔定律,在256nm紫外光波长,可测定油样的吸光度来确定相应油的量。 由于紫外光度法对于油种的敏感性较强,本方法的油样需采用标准物质。

环保

2021/05/31

称量仪器的校准

当称量仪器用于与质量控制相关的测量时,校准是必须定期执行的关键操作之一。国际上有许多标准规范都有这方面的要求,例如ISO9001、GMP法规以及与食品安全相关的一些标准。然而关于校准的定义、实施和校准的具体操作在全球范围内并没有一个完全统一的标准。在此,我们首先需要了解一下什么是校准,以及与调整和检定的区别。

其他

2022/04/23

推荐产品
供应产品

上海漾盟仪器有限公司

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 上海漾盟仪器有限公司

公司地址: 上海市徐汇区襄阳南路500号1402室 联系人: 黄健玮 邮编: 200031

仪器信息网APP

展位手机站