您好,欢迎访问仪器信息网
注册
杭州葛兰帕科技有限公司

关注

已关注

已认证

粉丝量 0

当前位置: 杭州葛兰帕 > 解决方案 > The Use of Oxygen in SEM Plasma Cleaning Equipment

The Use of Oxygen in SEM Plasma Cleaning Equipment

2011/03/03 23:48

阅读:0

分享:
应用领域:
发布时间:
2011/03/03
检测样品:
检测项目:
浏览次数:
0
下载次数:
参考标准:

方案摘要:

Getting the most out of your SEM has in the past meant baking out your column and being vigilant about wearing gloves when handling samples. As feature sizes decrease this may not be enough. Hydrocarbon buildup in SEM vacuum chambers can lead to less than ideal resolution. The electron beam reacts with contamination and deposits carbon on the sample which can cause charging and degrade image contrast. Oxygen plasma has long been used for cleaning surfaces in a vacuum. O2 is split into oxygen ions and radicals which are effective at removing organic contaminants. Manufacturers have produced low energy plasma cleaners that pull oxygen ions and radicals out of “thin air.” While this may seem like “snake oil”, it actually does work. This approach works, is easy to use, and has very little setup, but it is very slow. If you have a “dirty” system you may spend days or weeks on an initial cleaning. We modified our Evactron® De-Contaminator to use welding grade oxygen. The investigation that we have performed indicates that there is a night and day comparison for effectiveness and speed. One or two four hour sessions with oxygen was shown to be more effective than using ambient air for weeks.

下载本篇解决方案:

资料文件名:
资料大小
下载
o2clean2007.pdf
236KB
相关方案

NanoBrook产品应用-12-ZetaPALS

文献名: Structural, morphological and optical properties of Bi NPs obtained by laser ablation and their selective detection of L-cysteine 作者: Ramon Gabriel Teixeira Rosaa, Celso de Araujo Duartea , Wido Herwig Schreinera, Ney Pereira Mattoso Filhoa, Arandi Ginane Bezerra Jr.b, Andersson Barisonc, Fernanda Maria Marins Ocamposc a Departamento de Física, Universidade Federal do Paraná Centro Politécnico, CP 19044, 81531-990 Curitiba (PR), Brazil b Departamento Acadêmico de Física, Universidade Tecnológica Federal do Paraná, 80230-901 Curitiba (PR), Brazil c Departamento de Química, Universidade Federal do Paraná Centro Politécnico, CP 19081, 81531-990 Curitiba (PR), Brazil 摘要:In the present work we show the results of the investigation of the properties of bismuth nanoparticles (NPs) obtained by the laser ablation in water. The samples were characterized by various techniques: UV/vis spectroscopy, dynamic light scattering, transmission electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, nuclear magnetic resonance and zeta potential. The NPs were metallic and surface oxidated, exhibiting absorption peak at 257 nm due to the surface plasmon resonance. The interaction between the NPs and various amino acids was studied and revealed a selective sensibility to cysteine on a range of concentration from 80 to 720 μM, which we attribute to a dimerization of cysteine to cystine probably complexed to the nanoparticle surface by electrostatic interactions, leading to the modification of the NP absorption spectrum. 关键词:Bismuth; Nanoparticles; Laser ablation; Cysteine

2015/04/16

城市污水中TOC与COD的关系

TOC与COD的测定方法不同。测定COD是采用强氧化剂和加热回流的方法,只能将水中的有机物部分氧化(氧化率较低),并且测定时间较长,即使目前一些快速的

环保

2017/11/16

EYELA MCR流动化学法制备长链脂肪酯

1、恒温槽采用铝块加热的方式,50~200℃范围内进行高精度温度调节。 2、反应柱分为内径3·5·10mmX长度50·100mm的六个种类,材质分为不锈钢材质和玻璃材质,玻璃反应柱适用于酸性样品的反应。 3、反应柱在恒温槽内的固定操作十分简单,只需一个拉杆动作即可完成安装。 4、样品导入端分为液相反应用和气液反应用2个种类(选购) 5、氢气、氧气、二氧化碳气的气体反应用大流量控制单元也可配备(选购)

石油/化工

2018/11/16

连华科技 医疗污水检测方案

医疗污水包含了多种细菌、重金属、有机溶剂及酸碱溶液等生化有毒有害物质。如上述物质直接排放,将会对自然生态及人类生活环境造成危害。我国对医疗污水有清晰的排放标准。连华科技对于《医疗机构水污染物排放标准GB18466-2005》中所涉及的参数,多款便携及实验室仪器及耗材可满足检测需求

环保

2020/02/14

推荐产品
供应产品

杭州葛兰帕科技有限公司

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 杭州葛兰帕科技有限公司

公司地址: 浙江杭州滨江区江南大道3778号元天科技大厦A座6004室 联系人: 许风涛 邮编: 310053

友情链接:

仪器信息网APP

展位手机站