Staircase Potentio Electrochemical Impedance Spectroscopy and automatic successive ZFit analysis
2008-10-30 10:48
浏览:1146次
分享:
资料摘要:
It is sometimes useful to automate some measurements. With EC-Lab and EC-Lab Express, it is possible to automatically perform successive impedance measurements during a potential sweep with the SPEIS (Staircase Potentio Electrochemical Impedance)technique. This technique allows the user to do in the same experiment successive potential steps with an electrochemical impedance spectroscopy measurement on each. For each experiment, the user defines the conditions. One of the applications of this technique is to study electrochemical reaction kinetics along steady-state curves. Note that the same process can be used in galvanostatic mode with the SGEIS technique.
下载本篇资料:
Staircase Potentio Electrochemical Impedance Spectroscopy and automatic successive ZFit analysis
574KB
相关资料
利用Kramers-Kronig(K-K)转换,在已知f𔾴和f→∞的虚部随频率的变化时,可以计算出一个因果的、稳定的、线性的、定时的、有限的系统的传递函数的实部。或者,当传递函数实部的变化已知时,可以计算传递函数的虚部[1-4]。
测量电极反应的阻抗时,可以使用实部的实验值计算虚部,或者使用虚部的实验值计算实部。将计算阻抗ZKK与实验阻抗Z进行比较,是检验K-K变换适用条件下阻抗测量有效性的有用工具。
BioLogic电化学工作站EC-Lab软件中包含自校准功能。仪器使用过程中,为保证其精度,一般建议客户在夏冬两季分别对仪器进行两次自校准。当需要初步检测通道板状态时,也需要对通道板进行自校准。
BioLogic电化学工作站主要分为VMP3系列(包含SP-50、SP-150、VSP、VMP3等)和VMP-300系列(包含SP-200、SP-240、SP-300、VSP-300、VMP-300等)。两种系列的自校准方法不同,本文主要介绍VMP3系列电化学工作站的自校准方法。
MTZ-35阻抗分析仪测试流程.MTZ-35测试可以通过在DC2或DC3 模拟电解池上运行交流阻抗实验进行测试。
对于有效的阻抗测量,所研究的系统应该是线性的、稳定的、因果的和平稳的。EC-Lab的THD质量指示器可用于测试系统的线性度。