产品名称:Glass Inlet Liners
仪器厂商:PerkinElmer/美国 珀金埃尔默
价格:面议
库存:是

Capillary Split/Splitless Injector Liners
Description ID mm OD mm Length mm Pkg Part no.
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – General purpose use, ideal for chlorinated pesticides analyses 2 4 86.2 5 N6502001
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken 4 6.2 92.1 5 N6121020
Split Glass Liner (with wool) – Universal liner for general purpose analyses 4 6 92.1 5 N6502009
Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 4 6 92.1 5 N6502010
Clarus Cup Split Glass Liner – Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean 4 6 92.1 5 N6502011
Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections 4 6 92.1 5 N6502012
Uniliner Deactivated Glass Liner (with wool) – Universal liner or general purpose analyses 4 6.2 92.1 5 N6121022
Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with headspace and purge/trap 1 6.2 92.1 5 N6502006
Quartz Liner for Splitless Operation (ships with instrument) –Standard injector liner 2 6.2 92.1 1 N6121002
Glass Liner for Splitless Operation – Universal liner for general purpose analyses 2 6.2 92.1 1 N6101372
Deactivated Glass Liner for Splitless Operation (with wool) – Good for analyses of trace samples 2 6.2 92.1 5 N6121021
Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken 2 6.2 92.1 5 N6502004
Quartz Liner for Split Operation – Good for large volume injection samples 4 6.2 92.1 1 N6121001
Glass Liner for Split Operation – Universal liner for general purpose analyses 4 6.2 92.1 1 N6101052
Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems 4 6.2 92.1 5 N6502003
Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean 4 6.2 92.1 5 N6502005
Zero Dilution Glass Outer Liner – Ideal for trace HS work. Use in conjunction with N1011446 2 6.3 90 1 N1011445
Zero Dilution Glass Inner Liner – Ideal for trace HS work. Use in conjunction with N1011445 2 6.3 90 1 N1011446
Programmed Temperature Split/Splitless (PSS) Injector Liners
Quartz Liner for Splitless operation (ships with instrument) – Excellent liner for low volume analyses 1 4 86.2 1 N6121006
NEW! Siltek Deactivated Glass PSS Liner – Used for low volume trace sample analyses 1 4 86.2 5 N6502000
Quartz Liner for Split operation (ships with instrument) – Approved PerkinElmer standard injector liner 2 4 86.2 1 N6121004
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) – Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken 2 4 86.2 5 N6502001
NEW! Siltek Deactivated Glass Liner for Split operation – Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 2 4 86.2 5 N6502002
Zero Dilution Outer Liner –Use in conjunction with N1011446 2.8 4 83 1 N1011447
Zero Dilution Inner Liner –Use in conjunction with N1011447   2 73 1 N1011446
On-column Glass Liner 2.4 4 86.2 1 N6101539
Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 1 N6121008
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 5 N6121009
Packed Column Injector Liners
Drilled Uniliner (hole on top) – Excellent liner for high sample recovery and linearity, recommended for aqueous injections. 4 6.2 92.1 5 N6121022
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. Good for PPC equipped GCs 4 6.2 92.1 5 N6502013
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,active samples, high recovery and linearity 4 6.2 92.1 5 N6502014
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, active samples, high recovery and linearity 4 6.2 92.1 5 N6502015
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue 4 6.2 92.1 5 N6502016
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction 4 6.2 92.1 5 N6502017
Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375
Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003
Colored Injector Liners
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility 2 4 86.2 5 N9306232
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306233
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 1 N9306234
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306235
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample. 4 6.2 92.1 5 N9306236
PSS Splitless deactivated glass liners with deactivated wool 5/pk. 1.25 4 86.2 5 N9306237