Description
|
ID mm
|
OD mm
|
Length mm
|
Pkg
|
Part no.
|
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – General purpose use, ideal for chlorinated pesticides analyses
|
2
|
4
|
86.2
|
5
|
N6502001
|
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken
|
4
|
6.2
|
92.1
|
5
|
N6121020
|
Split Glass Liner (with wool) – Universal liner for general purpose analyses
|
4
|
6
|
92.1
|
5
|
N6502009
|
Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range
|
4
|
6
|
92.1
|
5
|
N6502010
|
Clarus Cup Split Glass Liner – Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean
|
4
|
6
|
92.1
|
5
|
N6502011
|
Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections
|
4
|
6
|
92.1
|
5
|
N6502012
|
Uniliner Deactivated Glass Liner (with wool) – Universal liner or general purpose analyses
|
4
|
6.2
|
92.1
|
5
|
N6121022
|
Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with headspace and purge/trap
|
1
|
6.2
|
92.1
|
5
|
N6502006
|
Quartz Liner for Splitless Operation (ships with instrument) –Standard injector liner
|
2
|
6.2
|
92.1
|
1
|
N6121002
|
Glass Liner for Splitless Operation – Universal liner for general purpose analyses
|
2
|
6.2
|
92.1
|
1
|
N6101372
|
Deactivated Glass Liner for Splitless Operation (with wool) – Good for analyses of trace samples
|
2
|
6.2
|
92.1
|
5
|
N6121021
|
Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken
|
2
|
6.2
|
92.1
|
5
|
N6502004
|
Quartz Liner for Split Operation – Good for large volume injection samples
|
4
|
6.2
|
92.1
|
1
|
N6121001
|
Glass Liner for Split Operation – Universal liner for general purpose analyses
|
4
|
6.2
|
92.1
|
1
|
N6101052
|
Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems
|
4
|
6.2
|
92.1
|
5
|
N6502003
|
Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean
|
4
|
6.2
|
92.1
|
5
|
N6502005
|
Zero Dilution Glass Outer Liner – Ideal for trace HS work. Use in conjunction with N1011446
|
2
|
6.3
|
90
|
1
|
N1011445
|
Zero Dilution Glass Inner Liner – Ideal for trace HS work. Use in conjunction with N1011445
|
2
|
6.3
|
90
|
1
|
N1011446
|
Programmed Temperature Split/Splitless (PSS) Injector Liners
|
Quartz Liner for Splitless operation (ships with instrument) – Excellent liner for low volume analyses
|
1
|
4
|
86.2
|
1
|
N6121006
|
NEW! Siltek Deactivated Glass PSS Liner – Used for low volume trace sample analyses
|
1
|
4
|
86.2
|
5
|
N6502000
|
Quartz Liner for Split operation (ships with instrument) – Approved PerkinElmer standard injector liner
|
2
|
4
|
86.2
|
1
|
N6121004
|
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) – Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken
|
2
|
4
|
86.2
|
5
|
N6502001
|
NEW! Siltek Deactivated Glass Liner for Split operation – Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range
|
2
|
4
|
86.2
|
5
|
N6502002
|
Zero Dilution Outer Liner –Use in conjunction with N1011446
|
2.8
|
4
|
83
|
1
|
N1011447
|
Zero Dilution Inner Liner –Use in conjunction with N1011447
|
|
2
|
73
|
1
|
N1011446
|
On-column Glass Liner
|
2.4
|
4
|
86.2
|
1
|
N6101539
|
Liner/Hour Glass for POC Injector
|
2.4
|
4
|
19.05
|
1
|
N6101703
|
Quartz Split Liner with Silanized Glass Wool
|
2
|
4
|
86.2
|
1
|
N6121008
|
Quartz Split Liner with Silanized Glass Wool
|
2
|
4
|
86.2
|
5
|
N6121009
|
Packed Column Injector Liners
|
Drilled Uniliner (hole on top) – Excellent liner for high sample recovery and linearity, recommended for aqueous injections.
|
4
|
6.2
|
92.1
|
5
|
N6121022
|
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. Good for PPC equipped GCs
|
4
|
6.2
|
92.1
|
5
|
N6502013
|
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,active samples, high recovery and linearity
|
4
|
6.2
|
92.1
|
5
|
N6502014
|
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, active samples, high recovery and linearity
|
4
|
6.2
|
92.1
|
5
|
N6502015
|
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue
|
4
|
6.2
|
92.1
|
5
|
N6502016
|
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction
|
4
|
6.2
|
92.1
|
5
|
N6502017
|
Wide-Bore Column Glass Liner
|
6
|
4
|
92.1
|
1
|
N6101375
|
Wide-Bore Column On/Off Quartz Liner
|
6
|
4
|
92.1
|
1
|
N6121003
|
Colored Injector Liners
|
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility
|
2
|
4
|
86.2
|
5
|
N9306232
|
Capillary splitless deactivated glass liners with deactivated wool.
|
4
|
6.2
|
92.1
|
5
|
N9306233
|
Capillary splitless deactivated glass liners with deactivated wool.
|
4
|
6.2
|
92.1
|
1
|
N9306234
|
Capillary splitless deactivated glass liners with deactivated wool.
|
4
|
6.2
|
92.1
|
5
|
N9306235
|
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample.
|
4
|
6.2
|
92.1
|
5
|
N9306236
|
PSS Splitless deactivated glass liners with deactivated wool 5/pk.
|
1.25
|
4
|
86.2
|
5
|
N9306237
|