MonitorStatic ControlAntistatic, Mats / Checker / MonitorMultimount ContinuousSurface Resistance CheckerEasily determine if a surface is dissipative, Continuously monitors single operator and ESD workstation—eliminating the need for periodic testing■ Meet ISO 9000 and ANSI/ESD S20.20 test logging requirements■ Audible and visual alarmsnotify operator of out-of-limit conditions■ Easily install on mostequipment or workbench surfacesUse this continuous monitor to ensure that critical ESD generators conductive, or insulative Ensure compliance toANSI/ESD S20.20-2007 per ESD TR53 Use optional electrodesfor resistance measurements of larger surfacesThis portable meter is perfect for quick checks of surface resistance for ESD control applications in electronics manufacturing or handling environments. Simply press and in sensitive areas are effectively grounded. Unit features green (grounded) 20028-08hold the test button until the bright LEDs display the reading level. Unit features an automatic test and red (not grounded) LEDs notifying operator of continuouspersonal and mat grounding status.The 4-mm parking snap allows time for the operator to disconnectthe coil cord from the wrist band and park it on this snap. Whileparked, the coil cord disables the alarm, allowing the operator toleave the workstation. Upon returning and removing the coil cordfrom the parking snap, the operator has six seconds to hook up tothe wrist band before the alarm sounds.What’s included: two 6-ft (1.8-m) mat monitor cords, two push-and-clinch snaps, mounting hardware and brackets, one set ofvoltage selector allowing the test voltage to switch from 10 V to 100 V if the measured resistance exceeds 1 x 10E5 ohms. Two banana jacks and an electrode toggle switch allow for the connection of two optional external 5-lb electrodes that measure surface resistance point to point, or resistance to equipment ground.What’s included: one 9 V battery and20028-01 hook-and-loop fasteners, andNIST-traceable calibration report supplied by the manufacturer.SpecificationsRange: 500 KΩ to 10 MΩ Dimensions (L x W x H):NIST-traceable calibration report supplied by the manufacturer.SpecificationsRange: 10E3 to 10E12 ohms Power: one 9 V batteryAccuracy: ±1?2 decade Dimensions (L x W x H): 51?4" x 3" x 1" Alarm response time: 50 msCatalog number Description33?4" x 2" x 1" (9 .5 x 5 x 2 .5 cm)Power (50/60 Hz)PriceDisplay: 10 colored LEDsCatalog numberDescription(13 .3 x 7 .6 x 2 .5 cm)Price SN-20028-08Continuous staticcontrol monitor220 VACSN-20028-01Surface resistance checker ESD MatsEliminate static from your work areaSN-20028-03 Test leads, one pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SN-20028-05 External electrodes, 5 lb, one pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . SpecificationsCompliance: ANSI/ESD S20 .20 CatalogStatfreeDimensionsRTG number Benchtop matsmaterial type (L x W x thickness)(Ω) Package Price SN-26809-60? T2, blue SN-26809-61? T2, gray48" x 24" x 1?16"(122 x 61 x 0 .2 cm)106 to 108dissipativeMat kit SN-26809-62 T2, blue 480" x 24" x 1?16"side/Roll 26809-6026809-6126809-74SN-26809-64 T2, graySN-26809-63 T2, blue 480" x 36" x 1?16"SN-26809-65 T2, gray104conductivesideRoll Desco mats are available in a variety of materials for your static control applications and meet ANSI/ESD S20.20 requirements.Statfree® Type T2 Benchtop Mats have superior heat-, chemical-, Floor matsSN-26809-73? SN-26809-74??CVi72" x 48" x 1?8" 103 to 105 Mat kit36" x 24" x 1?2" 103 to 105 Mat kit and wear-resistance. All feature two layers of 100% nitrile butadiene industrial-grade rubber the top layer is dissipative andthe bottom layer is conductive. Available in blue or gray, in kit or roll.Statfree® Type CV Floor Mat Kit has excellent chemical-resistance,is humidity independent, and is made of conductive vinyl.Statfree® Type i Floor Mat Kit interlocks to provide anti-fatigueproperties over large areas. Mat features conductive rubber construction and an ergonomic dome/support cell structure design.???Includes ground kit 26809-66 ?Includes ground kit 26809-76 Includes snap kit 26809-68SN-26809-66 Wrist strap/bench mat common ground kit.Includes common point 15-ft (4 .6-m) ground cord, resistor with 10-mm snap stud, and universal snap kit 26809-68 . . . . . . . . . . . . . . . . . . . . . . . . . .SN-26809-68 Universal snap kit. Includes one 10-mm male stud,one 10-mm female socket, and one long and one short screw . . . . . . . . . . . . . . . . .SN-26809-76 Floor mat ground kit. Includes 15-ft (4 .6-m) ground cord,resistor with 10-mm snap stud, and snap kit 26809-68 . . . . . . . . . . . . . . . . . . . . . . .Compact Static Charge MetersStatic ControlAntistatic, Meters / Blowers / Test KitSt Measure the magnitude and polarity of electrostatic fields produced by charged objectsAnalog Meter instantly measures static charges. Achieve higher resolution whenmeasuring below 3000 volts by setting the range selector to LOW setting measure up to30,000 volts in the HIGH range simply by multiplying the reading by ten. The “quick zero”function re-zeros the meter for repetitive measurements.Digital Meter with Output measures electrostatic fields by increasing the meter to chargedsurface distance. Meter features a 31?2-digit, 0.4"H LCD. HOLD button freezes currentreading. Easily zero the meter with the turn of a knob, there is no need to re-zero betweenmeasurements. The output lets you permanently record your results. Order charge platedetector separately below to verify proper operation of air ionizers and increase metersensitivity by a factor of ten.What’s included: one 9 V battery. Digital meter 37715-70 also includes a carrying case.Analog meter17797-30Leather case17797-32 Catalog number TypeSN-17797-30 AnalogRange0 to 30,000 VOutput—Dimensions (L x W x H)43?8" x 25?8" x 13?8" (11 .2 x 6 .7 x 3 .5 cm)Price SN-37715-70 Digital 0 .00 to ±19 .99 kV at 1" 10 mV/kV 41?4" x 23?8" x 1" (10 .8 x 6 .1 x 2 .5 cm)SN-17797-32 Leather case for meter 17797-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SN-09376-04 Replacement batteries, 9 V . Pack of 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ionized Air BlowersAutomatically maintain a balanced ion outputPortable Ionized Air Blower is compact, lightweight, and ideal forfield use. Blower features an emitter cassette that slides out for easy cleaning and replacement. The grounded metal case eliminates high-voltage fields for greater safety. Airflow output can be adjusted for greater worker comfort. Visual and audible alarms and “Clean Me” indicator automatically signal when cleaning and maintenance are required.Benchtop Ionized Air Blower emits ions in a true laminar flowreducing ion recombination and emitter contamination. AC ionizing system neutralizes static charges at a greater distance while the fixed temperature heater increases worker comfort. Gold-plated emitters provide longer service life.What’s included: NIST-traceable calibration report supplied by the manufacturerand a 71?2-ft (2.2-m) power cord (on 120 VAC models only).Catalog number Type Max airflow output Dimensions (W x H x D) Power (50/60 Hz) PriceSN-26809-44 Portable 81?2" x 73?4" x 31?2" 120 VAC 26809-50 Digital meterwith output37715-70 SN-26809-46SN-26809-50 Benchtop77 cfm117 cfm(21 .6 x 19 .7 x 8 .9 cm)11" x 9" x 7"240 VAC120 VAC SN-26809-52(27 .9 x 22 .9 x 17 .8 cm)240 VAC26809-44 SN-26809-48 Replacement emitter cassettes for portable ionized air blower . One pair . . . . . . . . . . . . . . . . . . . . . Ionization Test KitProvides convenience and portability for testing of air ionizersUse this ionization test kit to conduct regular auditing of air ionization equipment ensuringcompliance. Test kit includes a static field meter to measure the offset voltage (balance)and charge decay of air ionizers, along with a charger for placing a ±1000 V charge onthe included conductive plate to meet ANSI/ESD SP3.3 standards. System is easy to use place the plate assembly on the static field meter, zero the meter, and then begin takingmeasurements. Static meter also features a Hold function allowing you to easily read orsave measurements on the screen for later reference.What’s included: digital static field meter, slide-on conductive plate, charger, data outputcord, carrying case, two 9 V batteries, and NIST-traceable calibration report supplied by the manufacturer.Specifications Range Low: 0 to ±1 .99 kV / inchHigh: 0 to ±19 .99 kV / inch Catalog numberSN-20028-09Accuracy Monitor output: ±5% of reading±10 mV Display: ±5% ofreading ±2 counts DescriptionIonization test kitStability: ±10 countsDisplay: LCDPower: one 9 V batteryDimensions (L x W x H): 5" x 23?4" x 1"(12 .7 x 7 x 2 .5 cm)Price美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器,美国Desco静电消除器
留言咨询