当前位置: 仪器信息网 > 行业主题 > >

双十八烷氧基

仪器信息网双十八烷氧基专题为您提供2024年最新双十八烷氧基价格报价、厂家品牌的相关信息, 包括双十八烷氧基参数、型号等,不管是国产,还是进口品牌的双十八烷氧基您都可以在这里找到。 除此之外,仪器信息网还免费为您整合双十八烷氧基相关的耗材配件、试剂标物,还有双十八烷氧基相关的最新资讯、资料,以及双十八烷氧基相关的解决方案。

双十八烷氧基相关的耗材

  • C18 十八(烷)基
    【固相萃取薄膜片】 品  名直 径膜 厚包装单位(枚)Cat.No.C18 十八(烷)基47mm0.5mm205010-3000690mm0.5mm105010-30008C18 FF 十八(烷)基47mm0.75mm205010-3001090mm0.75mm105010-30011C8 辛基47mm0.5mm205010-3000290mm0.5mm105010-30003SDB-XC 聚苯乙烯47mm0.5mm205010-3001590mm0.5mm105010-30016SDB-XD30mm0.5mm405010-3004547mm0.5mm205010-30046SDB-RPS 磺化SDB47mm0.5mm205010-3004190mm0.5mm105010-30042ANION-SR 离子交换47mm0.5mm205010-3002190mm0.5mm105010-30022CATION-SR 离子交换47mm0.5mm205010-3003190mm0.5mm105010-30032螯合物47mm0.5mm205010-3005590mm0.5mm105010-30056碳47mm 0.5mm205010-30060油&润滑脂47mm-205010-3007090mm-105010-30071EZ小柱 RP-1 25mm-50个5010-30080EZ小柱 RP-1 服务包25mm-500个5010-30081
  • C18 SD 十八(烷)基
    类 型标 准(1.2mL)深度(2.5mL)品 名包装单位(个)Cat.No.包装单位(个)Cat.No.C18 SD十八(烷)基15010-3020215010-3030235010-3020035010-30300125010-30203125010-30303C8 SD辛基15010-3020715010-3030735010-3020535010-30305125010-30208125010-30308C2 SD乙基 15010-3021215010-3031235010-3021035010-30310125010-30213125010-30313MPC SD苯磺酰乙基辛基混合相15010-3021715010-3031735010-3021535010-30315125010-30218125010-30318通用树脂(URP)15010-3022215010-3032235010-3022035010-30320125010-30221125010-30321滤板15010-3312115010-3312435010-3312235010-33125125010-33127125010-33128
  • 甲氧基测定装置成套玻璃7460
    甲氧基测定装置成套玻璃7460由上海书培实验设备有限公司提供,采用高硼硅玻璃材质,提供实验室整套玻璃器皿:玻璃烧杯,玻璃容量瓶,点样毛细管,冷凝管,称量瓶,培养皿,层析柱,比色管,玻璃比色皿,干燥器,漏斗(砂芯漏斗,分液漏斗,三角漏斗)等等产品名称:甲氧基测定装置成套玻璃7460规格:7460材质:高硼硅玻璃测定法: 取干燥的供试品(相当于甲氧基10mg),精密称定,置烧瓶中,加熔融的苯酚2.5ml与HI 5ml,连接上述装置 另在两个接受容器内,分别加入10%醋酸钾的冰醋酸溶液6.与4ml,再各加溴02ml 通过支管将C02或N2气流缓慢而均衡地(每秒钟1~2个气泡为宜)通入烧瓶,缓缓加热使温度控制在恰使沸腾液体的蒸气上升 50ml圆底烧瓶,侧部具一内径为1mm的支管供导入二氧化碳或氮气流用瓶颈垂直装有长约25cm、内径为9mm的直形空气冷凝管E,其上端弯曲成出口向下、并缩为内径2m的玻璃毛细管,浸入内盛水约2ml的洗气瓶B中,洗气瓶具出口为- -内径约7m的玻璃管,其末端为内径4m可拆卸的玻璃管,可浸入两个相连接的接受容器C、D中的第一个容器C内液面之下。
  • 玻璃羟丙氧基测定仪装置 带水浴支架
    玻璃羟丙氧基测定仪装置 带水浴支架由上海书培实验设备有限公司提供,适用于各大实验室、科研单位,产品质量优质,欢迎新老客户来电咨询选购。玻璃羟丙氧基测定仪装置 带水浴支架 产品介绍:图中D为25ml双颈蒸馏瓶,侧颈与外裹铝箱的长度为95mm的分馏柱E相连接:C为接流管,末端内径为0.25~1.25mm,插入蒸馏瓶内;B为蒸汽发生管(25mm×150mm),亦其末端内径为0.25~1.25mm的气体导入管,并与C相通;F为冷凝管,外管长100mm,与E连接。G为125ml具刻度的带浴A中,维持温度为155°C 测定法  取各药品项下规定量的供试品,精密称定,置蒸馏瓶D中,加30%(g/g)三氧化铬溶液10ml。于蒸汽发生管B中装入水至近接头处,连接蒸馏装置。将B与D均浸入油浴中(可为甘油),使油浴液面与D瓶中三氧化铬溶液的液面相一致。开启冷却水,必要时通入氮气流并控制其流速为每秒钟约1个气泡。于30分钟内将油浴升温至155℃,并维持此温度至收集馏液约50ml,将冷凝管自分馏柱上取下,用水冲洗,洗液并入收集液中加酚酞指示液2滴,用氢氧化钠滴定液(0.02mol/L)滴定至pH为6.9~7.1(用酸度计测定),记下消耗的容积V[1](ml),而后加碳酸氢钠0.5g与稀硫酸10ml,静置至不再产生二氧化碳为止,加碘化钾1.0g,密塞,摇匀,置暗处放置5分钟,加淀粉指示液1ml,用硫代硫酸钠滴定液(0.02mol/L)滴定至终点,记下消耗的容积V[2](ml)。另作空白试验,分别记下消耗的氢氧化钠滴定液(0.02mol/L)与硫代硫酸钠滴定液(0.02mol/L)的容积V[a]与V[b](ml),按下式计算,即得。  OCH2CHOHCH3 %=(V[1]M[1]-KV[2]M[2])×(0.0751/W)×100%  式中  K为空白校正系数M[1]V[a]/M[2]V[b];  V[1]为供试品消耗氢氧化钠滴定液(0.02mol/L)的容积,ml;  V[2]为供试品消耗硫代硫酸钠滴定液(0.02mol/L)的容积,ml;  V[a]为空白试验消耗氢氧化钠滴定液(0.02mol/L)的容积,ml;  V[b]为空白试验消耗硫代硫酸钠滴定液(0.02mol/L)的容积,ml;  W为供试品的重量,g;  M[1]为氢氧化钠滴定液的浓度;  M[2]为硫代硫酸钠滴定液的浓度。玻璃羟丙氧基测定仪装置 带水浴支架 产品配置:羟丙氧基测定仪:298元羟丙氧基测定仪+支架:489元羟丙氧基测定仪+支架+水浴:1200元单水浴:640元单支架:189元
  • 7470羟丙氧基测定装置
    7470羟丙氧基测定装置由上海书培实验设备有限公司提供,选用高硼硅玻璃材质,由六个配件组成装置,提供实验室整套玻璃器皿:玻璃烧杯,玻璃容量瓶,点样毛细管,冷凝管,称量瓶,培养皿,层析柱,比色管,玻璃比色皿,干燥器,漏斗(砂芯漏斗,分液漏斗,三角漏斗),玻璃试管,量筒,离心管,三角烧瓶,玻璃棒,试剂瓶,刻度吸管,移液管,滴定管,溶剂过滤器,载玻片等等产品介绍:产品名称:7470羟丙氧基测定装置规格:7470材质:高硼硅玻璃图中各部件:D为25ml双颈蒸馏瓶,侧颈与外裹铝箱的长度为95mm的分馏柱E相连接:C为接流管,末端内径为0.25~1.25mm,插入蒸馏瓶内;B为蒸汽发生管(25mm×150mm),亦其末端内径为0.25~1.25mm的气体导入管,并与C相通;F为冷凝管,外管长100mm,与E连接。G为125ml具刻度的带浴A中,维持温度为155°C 测定法:取各药品项下规定量的供试品,精密称定,置蒸馏瓶D中,加30%(g/g)三氧化铬溶液10ml。于蒸汽发生管B中装入水至近接头处,连接蒸馏装置。将B与D均浸入油浴中(可为甘油),使油浴液面与D瓶中三氧化铬溶液的液面相一致。开启冷却水,必要时通入氮气流并控制其流速为每秒钟约1个气泡。于30分钟内将油浴升温至155℃,并维持此温度至收集馏液约50ml,将冷凝管自分馏柱上取下,用水 冲洗,洗液并入收集液中加酚酞指示液2滴,用氢氧化钠滴定液(0.02mol/L)滴定至pH为6.9~7.1(用酸度计测定),记下消耗的容积V[1](ml),而后加碳酸氢钠0.5g与稀硫酸10ml,静置至不再产生二氧化碳为止,加碘化钾1.0g,密塞,摇匀,置暗处放置5分钟,加淀粉指示液1ml,用硫代硫酸钠滴定液(0.02mol/L)滴定至终点,记下消耗的容积V[2](ml)。另作空白试验,分别记下消耗的氢氧化钠滴定液(0.02mol/L)与硫代硫酸钠滴定液(0.02mol/L)的容积V[a]与V[b](ml),按下式计算,即得。 OCH2CHOHCH3 %=(V[1]M[1]-KV[2]M[2])×(0.0751/W)×100%式中K为空白校正系数M[1]V[a]/M[2]V[b];V[1]为供试品消耗氢氧化钠滴定液(0.02mol/L)的容积,ml;V[2]为供试品消耗硫代硫酸钠滴定液(0.02mol/L)的容积,ml;V[a]为空白试验消耗氢氧化钠滴定液(0.02mol/L)的容积,ml;V[b]为空白试验消耗硫代硫酸钠滴定液(0.02mol/L)的容积,ml; W为供试品的重量,g;M[1]为氢氧化钠滴定液的浓度;M[2]为硫代硫酸钠滴定液的浓度。
  • 正十八烷 reference substance for gas chromatography
    正十八烷 reference substance for gas chromatography
  • 1,2,3- 三(2 - 氰乙氧基)丙烷(TCEP)
    所有的固定液均应GC的要求而合成,具有纯度高杂质少,流失低,分子量分布窄的特点。使用之前,固定液必须涂敷于担体之上并干燥。
  • 1,2,3-三(2-氰乙氧基)丙烷
    气相色谱填充柱常用固定液
  • 针头,全氟烷氧基 (PFA),内径 0.3 mm,标准探针,适用于安捷伦集成自动进样器 (I-AS)
    安捷伦科技公司提供了专用于 Agilent ICP-MS 系统超痕量分析的快速、灵活、高精度集成自动进样器 (I-AS)。I-AS 是半导体应用以及所有涉及常见元素超痕量分析的应用(如临床应用和环境水平海水测定)的理想选择。此外,使用可选的智能序列分析软件还可以自动实现一系列 QA/QC 控制程序,如 EPA 方案。 带盖自动进样器,与 Agilent 7700 系列和 8800 三重四极杆 ICP-MS 配合使用 样品瓶上方不会有金属或驱动装置移动 连续流动清洗口,用于清洗探针 样品盘布局选择;可容纳小体积和大体积样品 3 × 100 mL 标样瓶或清洗瓶 可添加紧急样品 图形界面简化了序列设置 使用可选的智能序列分析软件执行全自动的 QA/QC 控制程序 专为所有半导体应用以及常见元素超痕量分析而设计 使用集成样品引入系统 (ISIS) 可进行自动稀释和离散采样 重置/停止开关 使用防腐蚀和耐氢氟酸的材料设计 用户可自行安装 样品盘规格:89 × 6 mL 样品瓶(类型 A);53 × 18 mL 样品瓶(类型 B);18 × 50 mL 样品瓶(类型 C);79 × 1.5 mL(或 2 mL)样品瓶 + 10 × 18 mL 样品瓶(类型 D);79 × 6 mL 样品瓶 + 10 × 18 mL 样品瓶(类型 E)
  • OLED阳极套件
    这种自组装套件专为科学爱好者设计,为他们提供最新技术的实践经验。已知OLED(有机发光二极管)器件提供更亮的光并且与LCD器件相比可以制造得更薄。OLED显示器不仅可以从玻璃基板(普遍可见)创建,而且可以在可弯曲的塑料材料上创建,以允许许多其他应用。OLED套件专为用户试验可弯曲基板而设计,可在其上构建OLED器件。该套件包括“作为阴极的镓 - 铟(Ga:In)共晶合金”,“电致发光油墨”,“作为阳极的PET上的多层石墨烯”和“作为阳极的氧化铟锡(ITO)涂覆的PET”。镓 - 铟(Ga:In)规格:样品大小:5克纯度: 99.99%熔点: 15.7?C密度: 6.2g /cm3电致发光油墨规格:样品大小: 20ml颜色:橙红色透明液体内容:钌配合物+专有聚合物(可忽略不计)PET多层石墨烯规格:样本尺寸: 2厘米x 1厘米粒度: 3-10微米基材厚度: 7密耳氧化铟锡(ITO)涂层PET规格: 样本大小: 1x1”电阻率: 60欧姆/平方基材厚度: 5密耳
  • 用于全氟烷氧基 (PFA) 惰性工具包的炬管,适用于与 Agilent 7700/8800 系列 ICP-MS 配套使用的全氟烷氧基 (PFA) 惰性样品引入工具包
    安捷伦生产了一系列优质 ICP-MS 备件、附件和消耗品,包括 PFA 惰性样品引入组件包备件。可提供各种附件,包括用于 7500 和 7700 ICP-MS 系统的接头和排废管、中心管组件以及炬管。所有的 PFA 惰性样品引入组件包备件都符合安捷伦的严格性能指标,有助于获得重要客户所期望的市场领先的 ICP-MS 性能。为了维护系统性能,确保根据推荐维护日程表定期更换消耗品。 完整的组件包包括 PFA 尾端盖、PFA 雾化室、连接管、可拆卸石英炬管、带 PFA 基座的炬管中心管(有 4 种可供选择:铂或蓝宝石,2.5 mm 或 1.5 mm 中心管)。 方便安装于 7700 标准帕尔帖冷却雾化室中。系统采用了一个简单的推入式炬管接头,帮助安装和拆卸。 不含 O 形圈的设计以及 PFA 的材质确保低背景等效浓度 (BEC) 和低检测限 (DL)。 可选的带气体端口(用于加入 O2/Ar)的连接管增加了有机溶剂分析的灵活性。 与 PFA 微流同心雾化器、带 I-AS 探头的 PFA 微流雾化器、PFA 同心 200 uL/min 雾化器和带探头的 PFA 同心 200 uL/min 雾化器兼容。
  • 样品管线,全氟烷氧基 (PFA),内径 0.15 mm,外径 1.6 mm,70 cm,3/包
    蠕动泵管在使用前需要先清洗。通常的方法是运行 5% HNO 3 (v/v) 溶液。如果用户使用 HCl,Tygon 管中的 Sn 会被洗脱出来。在这种情况下,使用新的蠕动泵管,以 0.1 rps 的速率泵入 3% HCl (v/v) ,时间不能超过一个小时 注意:某些化学试剂会腐蚀蠕动泵管。这样会导致样品引入管和排废管的泄露以及样品引入系统的腐蚀。 长寿命 耐受大多数化学试剂 不适用于样品引入——杂质含量太高
  • InfinityLab 接头,1.6 mm 外径,全氟烷氧基,用于 InfinityLab 安全盖,2/包
    Open or partially covered solvent bottles can lead to the evaporation of solvents and harmful solvent vapors. InfinityLab Stay Safe caps stop 99.9 % of solvents from leaching into the air – protecting both you and your coworkers. Over time, solvent composition can change, affecting your chromatographic results. Storing solvents with airtight Stay Safe caps prevents this problem, ensuring the long-term consistency of your mobile phase for more reproducible results. An easy-to-see time strip maintains optimal performance by letting you know when the filter needs replacing. InfinityLab Stay Safe caps have a GL45 thread and are compatible with Agilent solvent bottles. 阻止 99.9% 的溶剂释放到空气中 提高溶剂的长期稳定性 轻松提高并保持实验室安全性 安装简单 GL45 螺纹可与 Agilent 溶剂瓶兼容
  • 废液管,全氟烷氧基 (PFA),用于惰性工具包,适用于 Agilent 7700/8800 系列 ICP-MS 的全氟烷氧基 (PFA) 惰性样品引入工具包
    安捷伦生产了一系列优质 ICP-MS 备件、附件和消耗品,包括 PFA 惰性样品引入组件包备件。可提供各种附件,包括用于 7500 和 7700 ICP-MS 系统的接头和排废管、中心管组件以及炬管。所有的 PFA 惰性样品引入组件包备件都符合安捷伦的严格性能指标,有助于获得重要客户所期望的市场领先的 ICP-MS 性能。为了维护系统性能,确保根据推荐维护日程表定期更换消耗品。 完整的组件包包括 PFA 尾端盖、PFA 雾化室、连接管、可拆卸石英炬管、带 PFA 基座的炬管中心管(有 4 种可供选择:铂或蓝宝石,2.5 mm 或 1.5 mm 中心管)。 方便安装于 7700 标准帕尔帖冷却雾化室中。系统采用了一个简单的推入式炬管接头,帮助安装和拆卸。 不含 O 形圈的设计以及 PFA 的材质确保低背景等效浓度 (BEC) 和低检测限 (DL)。 可选的带气体端口(用于加入 O2/Ar)的连接管增加了有机溶剂分析的灵活性。 与 PFA 微流同心雾化器、带 I-AS 探头的 PFA 微流雾化器、PFA 同心 200 uL/min 雾化器和带探头的 PFA 同心 200 uL/min 雾化器兼容。
  • InfinityLab 接头,2.3 mm 外径,全氟烷氧基,用于 InfinityLab 安全盖,2/包
    Open or partially covered solvent bottles can lead to the evaporation of solvents and harmful solvent vapors. InfinityLab Stay Safe caps stop 99.9 % of solvents from leaching into the air – protecting both you and your coworkers. Over time, solvent composition can change, affecting your chromatographic results. Storing solvents with airtight Stay Safe caps prevents this problem, ensuring the long-term consistency of your mobile phase for more reproducible results. An easy-to-see time strip maintains optimal performance by letting you know when the filter needs replacing. InfinityLab Stay Safe caps have a GL45 thread and are compatible with Agilent solvent bottles. 阻止 99.9% 的溶剂释放到空气中 提高溶剂的长期稳定性 轻松提高并保持实验室安全性 安装简单 GL45 螺纹可与 Agilent 溶剂瓶兼容
  • InfinityLab 接头,3.2 mm 外径,全氟烷氧基,用于 InfinityLab 安全盖,2/包
    Open or partially covered solvent bottles can lead to the evaporation of solvents and harmful solvent vapors. InfinityLab Stay Safe caps stop 99.9 % of solvents from leaching into the air – protecting both you and your coworkers. Over time, solvent composition can change, affecting your chromatographic results. Storing solvents with airtight Stay Safe caps prevents this problem, ensuring the long-term consistency of your mobile phase for more reproducible results. An easy-to-see time strip maintains optimal performance by letting you know when the filter needs replacing. InfinityLab Stay Safe caps have a GL45 thread and are compatible with Agilent solvent bottles. 阻止 99.9% 的溶剂释放到空气中 提高溶剂的长期稳定性 轻松提高并保持实验室安全性 安装简单 GL45 螺纹可与 Agilent 溶剂瓶兼容
  • 实验室进样机配件
    实验室进样机配件专业为实验室仪器的连续喂料进样需要而设计的实验室进样机,为在线粒度仪等仪器提供连续的颗粒样品进样喂料。实验室进样机配件特色 在线性运动轨道上传送导向件,轨道设计用于运输特定部分的形状或产品。 独特的自消除设计减少传递到安装表面的振动。 实验室进样机配件特点 ? MLF024实验室供给机,机型小,不占用太多空间 ? 易于安装和操作 ? 可以调整轨道处理各种重量和长度的改变 ? 根据客户的需求,可以订购特定大小和形状的振动台 实验室进样机配件规格电源: 110…240VAC, 50-60Hz 装载频率: 10…200Hz 装载量: 达2 kg/分钟 ( 2kg/分钟 每次需求) 控制器和软件 实验室进样机MLF024介绍 控制器专门设计用于MLF024频率控制器和电源。控制器内置一个电源,外部可通过USB2.0通讯端口进行控制。软件为所有可能的实验提供了一个方便的平台。供给机频率调整可以通过相关的菜单选择,很方便。对于需要调整照明或其他可能单元的应用程序,控制器有一个附加DB9输出接口,带三个(24V @30A)PWM(0 ....100%)的32kHz通道(漏极开路),两个逻辑通道(TTL)和一个频率可调整至500Hz(24V @30A)的通道。
  • 样品管,全氟烷氧基 (PFA),内径 1.0 mm,外径 1/16 英寸,5 m,用于安捷伦集成样品导入系统 (ISIS 3)
    ISIS 3 大大提高了 Agilent 7800 ICP-MS 及 Agilent 7900 ICP-MS 的分析效率,而且还能增加高基质样品的运行时间。ISIS 3 的快速进样活塞泵与紧密连接的 7 通阀(紧挨着雾化器)可在不连续进样 (DS) 中缩短样品吸取及清洗时间。ISIS 3 可为高通量实验室的高基质样品分析提供无与伦比的分析效率。 高速提升泵 紧密连接的 7 通切换阀 能够减少样品的提升和清洗时间 恒流雾化消除了高速提升后的稳定化处理 减少到达仪器的样品量,减少清洁和维护需求 允许高基质样品运行更长时间 为不连续进样提供尽可能最高的通量 PC 控制的 3 通阀在内标和调谐溶液间切换 可进行全自动仪器优化和样品分析,无需手动切换管线
  • 样品管,全氟烷氧基 (PFA),内径 2.18 mm,外径 1/8 英寸,5 m,用于安捷伦集成样品导入系统 (ISIS 3)
    ISIS 3 大大提高了 Agilent 7800 ICP-MS 及 Agilent 7900 ICP-MS 的分析效率,而且还能增加高基质样品的运行时间。ISIS 3 的快速进样活塞泵与紧密连接的 7 通阀(紧挨着雾化器)可在不连续进样 (DS) 中缩短样品吸取及清洗时间。ISIS 3 可为高通量实验室的高基质样品分析提供无与伦比的分析效率。 高速提升泵 紧密连接的 7 通切换阀 能够减少样品的提升和清洗时间 恒流雾化消除了高速提升后的稳定化处理 减少到达仪器的样品量,减少清洁和维护需求 允许高基质样品运行更长时间 为不连续进样提供尽可能最高的通量 PC 控制的 3 通阀在内标和调谐溶液间切换 可进行全自动仪器优化和样品分析,无需手动切换管线
  • 光谱仪专用磨样机
    光谱仪磨样机MPJ-1A是一台主要应用于直读光谱仪样品前处理的重要仪器,针对铁基样品的前处理。样品制备好对其进行后期的处理,就是在磨样机上进行磨制,被测样品激发的一面一定要平,使样品纹理清晰,才能保证样品与激发台之间贴合度, 这样才能保证气体冲洗室的密封性,使样品得到更好的激发。刚购置过来的标样和从车间里面拿过来的样品表面都是未经处理过的,光谱仪是不能直接对它们进行分析的,我们需要将样品磨平、磨光滑才能在光谱仪上分析,一般磨样的工具采用专门的磨样机,AC220V电机带动36目的砂纸或砂轮片转动,在磨样的过程中,我们要把样品平衡地放在砂纸上,要用力均匀,要不然磨出来的样品就会不光滑,出现梯度。在使用磨样的时候,应将样品放在同一个位置磨,不要来回或左右摆动,要使磨出来的样品表面的纹路总是在同一个方向,不要出现交叉的纹路。由于铁样或不锈钢样品比较难磨,如果出现样品表面温度特别高的时候,我们可以用冷却水进行局部冷却以后再接着磨,直到把样品磨平,表面纹路统一为止,在样品磨好以后,我们就不能在磨的表面用手或其他的东西去触摸,也不要让灰尘覆盖表面,这样都会影响分析精度。磨样作为样品处理环节的重要组成,对于直读光谱仪的检测是非常重要的。
  • 样品管线,全氟烷氧基 (PFA),内径 0.3 mm,外径 1.6 mm,3 m,用于在线添加内标
    安捷伦独特的智能集成样品引入系统 (ISIS) 能够增强 Agilent 7500 系列 ICP-MS 的功能和灵活性。 由安捷伦设计并生产的 ISIS 拥有精度极高的蠕动泵并且可选的切换阀配置具有很高的灵活性。ISIS 的硬件能够嵌入在 7500 系列中,而且能够与 7500 联用,样品吸取和清洗速率快,极大提高了分析效率。安捷伦提供了各种更换部件和其他备件,以增强系统的分析能力并在长年累月的使用后仍维持系统的性能。 安捷伦提供内径 0.89 mm(3 个定位卡)、内径 0.25 mm(2 个或 3 个定位卡)或内径 1.02 mm(2 个定位卡)的 Tygon 蠕动泵管。 提供内径 0.8 mm、外径 1.6 mm 的 ETFE 样品管和内径 2 mm、外径 3 mm 的 PTFE 样品管。此外,还提供内径 0.3 mm、外径 1.6 mm 的 PFA 样品管。 提供各种三通、四通或两通。 可提供 PTFE 螺母和外径 3 mm 或 1.6 mm 的前后密封圈。 可购买小号或大号的螺旋管、蠕动泵管适配器和管夹。 还可提供用于阀维护的扳手和用于管线识别的标签。 可提供用于高样品通量、自动稀释或不连续进样的各种标准附件部件。 可提供用于各种泵管和样品管路接头(四通和接地端)的三通接口。 可提供用于阀的转子密封垫、螺母和密封圈。 还可购买额外的消耗品,如混合器、样品环、管线接口和塑料盘。
  • 14%氰丙基苯基聚硅氧烷气相色谱柱
    BP10 (1701) SGE 毛细管柱 气相色谱柱 14%氰丙基苯基聚硅氧烷常用于环境样品分析的中等极性固定相;高惰性、低流失;操作温度: -20°C - 280/300°C;相似固定相:DB-1701、HP-1701、RTX-1701、SPB-7、AT-1701、HP-1701和CP-Sil 19CB。BP10 (1701) SGE 毛细管柱 气相色谱柱 14%氰丙基苯基聚硅氧烷 BP10(1701)?SGE 毛细管柱订货号长度(m)内径(mm)膜厚?(μm)使用温度054253250.220.25-20?to?280/300054256300.250.25-20?to?280/300054259300.320.25-20?to?280/300054268250.320.5-20?to?280/300054270300.321-20?to?260/280054280250.531-20?to?260/280054283300.531-20?to?260/280
  • 填充柱〖20%(25%苯基75%甲基硅氧烷)〗
    气相色谱填充柱〖20%(25%苯基75%甲基硅氧烷)〗部件号描述规格LDPC20030-01820%(25%苯基75%甲基硅氧烷) 填充柱1/8"*1.8m 1. 柱管无特殊说明均为进口不锈钢管,有PEEK管、镍管、惰化管等柱管材料可选2. 采用进口优质填料,填装均匀3. 柱长度可依据客户要求订做4. 色谱柱两端的螺母压环等连接件均可选购,请及时沟通,以免无法连接
  • 惰性连接管,带气体端口,适用于 Agilent 7700/8800 系列 ICP-MS 的惰性全氟烷氧基 (PFA) 样品引入工具包
    安捷伦生产了一系列优质 ICP-MS 备件、附件和消耗品,包括 PFA 惰性样品引入组件包备件。可提供各种附件,包括用于 7500 和 7700 ICP-MS 系统的接头和排废管、中心管组件以及炬管。所有的 PFA 惰性样品引入组件包备件都符合安捷伦的严格性能指标,有助于获得重要客户所期望的市场领先的 ICP-MS 性能。为了维护系统性能,确保根据推荐维护日程表定期更换消耗品。 完整的组件包包括 PFA 尾端盖、PFA 雾化室、连接管、可拆卸石英炬管、带 PFA 基座的炬管中心管(有 4 种可供选择:铂或蓝宝石,2.5 mm 或 1.5 mm 中心管)。 方便安装于 7700 标准帕尔帖冷却雾化室中。系统采用了一个简单的推入式炬管接头,帮助安装和拆卸。 不含 O 形圈的设计以及 PFA 的材质确保低背景等效浓度 (BEC) 和低检测限 (DL)。 可选的带气体端口(用于加入 O2/Ar)的连接管增加了有机溶剂分析的灵活性。 与 PFA 微流同心雾化器、带 I-AS 探头的 PFA 微流雾化器、PFA 同心 200 uL/min 雾化器和带探头的 PFA 同心 200 uL/min 雾化器兼容。
  • BP225 – 50%氰丙基苯基聚硅氧烷
    BP225 &ndash 50%氰丙基苯基聚硅氧烷 · 中等极性固定相; · 低流失; · 键合交联; · 操作温度: 0.1 &ndash 1.0µ m膜厚 40° C - 230/250° C; · 相似固定相:DB-225、HP-225、RTX-225、AT-225、SP-2330、SPB-225和CP-Sil 43CB。 BP225&ndash 50%氰丙基苯基聚硅氧烷 内径(mm) 膜厚(µ m) 25m 50m 0.22 0.25 054352 054353 0.32 0.25 054358 &radic 0.53 0.5 054364 &minus &radic =这些规格我们同样提供,需要更详细信息请与我们联系.
  • BP225 – 50%氰丙基苯基聚硅氧烷 054358
    forte BP225 – 50%氰丙基苯基聚硅氧烷? 中等极性固定相;? 低流失;? 键合交联;? 操作温度: 0.1 – 1.0μm 膜厚 40°C - 230/250°C;? 相似固定相:DB-225、HP-225、RTX-225、AT-225、SP-2330、SPB-225 和CP-Sil 43CB;? 完整的毛细管柱典型应用,请参照附录A 第140 页。BP225 – 50%氰丙基苯基聚硅氧烷订货信息:内径(mm)膜厚(μm)25m50m0.220.250543520543530.320.25054358√0.530.5054364—√=这些规格我们同样提供,需要更详细信息请与我们联系。
  • 塑料试管PP进样管20ml适配进样机
    PP材质自动进样管ASX-560塑料管20ml方法参考:美国Teledyne CETAC 自动进样管ASX-560塑料进样管20mlPP材质刻度进样管可配套ICP-MS/ICP-AES ASX-520等全自动进样机使用,美国TELEDYNE分析仪表公司(TELEDYNE CETAC TECHNOLOGIES)用的自动进样器,适用于大批量样品的自动分析,但是由于溶样定容上机需要二次操作,很多单位因为样品量多烦恼,现在我公司研发出的PP进样管符合定容上机一体操作,刻度准确,透明度高,尺寸高12cm,可以和自动进样机完美匹配,配套型号:CETACTeledyne CETAC 自动进样器系统Teledyne CETAC 自动进样器系统APS-1650 ASX-110FR ASX-112FR ASX-1400 ASX-1600 ASX-280 ASX-560 ASX-7000 ASXPRESS PLUS ENC DC series ENC-560 MVX-7100 Oils 7400 SDX HPLD SimPrep XLR-860也可配套热电,安捷伦,PE,ESA SK系列原子荧光光谱仪自动进样器专业PP自动进样管。主要特征及要点: 1、比色管不是试管,不能加热,且比色管管壁较薄,要轻拿轻放;2、同一比色实验中要使用同样规格的比色管;    3、清洗比色管时不能用硬毛刷刷洗,以免磨伤管壁影响透光度;从而影响使用效果;4、比色时一次只拿两支比色管进行比较且光照条件要相同;5、透明度高,肉眼能看到管内容积;与玻璃比色管相比,最大的优点是耐摔,使用时间长;6、杯口液体倒出流畅,液体不会顺着倒口处往下滴流;7、对于酸、碱、酒精、醇类的化学品有出色的抵抗体;8、耐温可达105℃左右;;9、多用于疾控中心、地质地矿等各种化学分析实验室比色实验;
  • HT8 – 8%苯基聚碳硼硅氧烷 054680
    forte HT8 – 8%苯基聚碳硼硅氧烷? 独特的超高温柱;? 适用于多氯联苯(PCB)分析;? 根据PCB 邻位上取代基和沸点来分离;? 操作温度: 0.1 – 1.0μm 膜厚 -20°C - 360/370°C;? 无等同或相似产品;? 完整的毛细管柱典型应用,请参照附录A 第140 页。HT8 – 8%苯基聚碳硼硅氧烷订货信息:内径 (mm)膜厚(μm)10m12m25m30m50m60m0.10.1054690√ ————0.220.25√ 054674054675√ 054676√ 0.250.25√√ √ 054677√ √0.320.25√054679054680√ 0546810546820.530.5√054684054685√——√=这些规格我们同样提供,需要更详细信息请与我们联系。
  • BPX90 –90%氰丙聚硅亚苯基-硅氧烷
    forte BPX90 – 90%氰丙聚硅亚苯基-硅氧烷? 独有的强极性柱,是分离芳香物、石化产品、杀虫剂、PCB 和FAMEs 异构体的理想之选;? 热稳定、键合相柱,主要通过极性分离;? 操作温度:80°C - 280°C;? 无直接替代产品。BPX90 – 90%氰丙聚硅亚苯基-硅氧烷订货信息:内径(mm)膜厚(μm)15m30m60m0.250.250545700545800545900.320.5054573054583054593
  • BPX608 – 35%苯基聚硅苯-硅氧烷 054823
    forte BPX608 – 35%苯基聚硅苯-硅氧烷? 特别适用于分离EPA 608 有机金属杀虫剂;? 操作温度:10°C - 360/370°C;? 等同产品:DB-608、HP-608、RTX-35、SPB-608、007-608 和ZB-35;? 完整的毛细管柱典型应用,请参照附录A 第140 页。BPX608 – 35%苯基聚硅苯-硅氧烷订货信息:内径 (mm)膜厚(μm)25m0.320.4054823
Instrument.com.cn Copyright©1999- 2023 ,All Rights Reserved版权所有,未经书面授权,页面内容不得以任何形式进行复制