当前位置: 仪器信息网 > 行业主题 > >

智能型光损耗测试仪

仪器信息网智能型光损耗测试仪专题为您提供2024年最新智能型光损耗测试仪价格报价、厂家品牌的相关信息, 包括智能型光损耗测试仪参数、型号等,不管是国产,还是进口品牌的智能型光损耗测试仪您都可以在这里找到。 除此之外,仪器信息网还免费为您整合智能型光损耗测试仪相关的耗材配件、试剂标物,还有智能型光损耗测试仪相关的最新资讯、资料,以及智能型光损耗测试仪相关的解决方案。

智能型光损耗测试仪相关的耗材

  • LTS1500 光损耗测试仪光纤通讯 Loss Test Set-LTS
    LTS1500 光损耗测试仪光纤通讯 Loss Test Set-LTSThe FTE-4000 TTI Hand Held Variable Optical Attenuator is available in two models, with 40 dB attenuation level or 80 dB attenuation level to meet single mode testing requirements. Like the rest of the FTE line, the VOA has an onboard help feature. The FTE-4000 has a built in output power monitor to assist in setting the appropriate attenuation levels and a sweep mode which can scan the attenuation across desired levels. It is rugged with a splash proof housing with a highly protective boot. The FTE-4000 can assist in the testing of system budget compliance, balancing transmitter power and adjusting receiver attenuation settings.Features?Integrated Power Meter?Up to 80 dB Attenuation?Typical Insertion Loss ?Remotely Program Sweep Settings?Adjustable step sizes?USB PC Interface w/Remote Operation?Absolute/Relative Attenuation Settings?Calibrated at 1310/1550?Sealed Rugged Case?Lowest Cost Hand Held VOA?4” Color DisplayOrdering InformationFTE-4000-4040 dB Variable Optical AttenuatorFTE-4000-8080 dB Variable Optical AttenuatorFTE-4000 SpecificationsAttenuation RangeFTE-4000-4 2 to 40dBFTE-4000-8 4 to 80dBWavelength Range1310, 1550 nmResolution.01 dBUncertainty+/- 0.5 dBRepeatability+/- 0.1 dBInsertion LossReturn Loss50 dBMax Input Power27 dBmGraphical Display4 in Color TFTDimensions7.75 x 4.5 x 2.25 inchesWeight2 lbsBatteryRechargeable NiMH - 6 hours operating timePower100-240 universal US, GB, EU, AU MainsEnvironmental Operation-10°C to + 40°CAccessories IncludedUniversal power supply. FC and SC adaptors,CertSof VI Software, USB Cable and Manual
  • 智能型超声波加湿器
    智能型超声波加湿器 新闻资讯报道:据了解,当空气的相对湿度低于30%RH时,就比较容易产生静电了。千万不要小看了静电所造成的危害,更不可忽视空气过于干燥而引发的"静电"对工业生产所造成的影响和损失;因此,一般的防静电工作区对环境相对湿度要求以不低于50%RH为宜。现如今的绝大多数工厂企业在产品的生产,储存以及过程中对环境湿度都是有着一定的要求! 那么,在干燥的秋冬季节一些工厂企业的生产车间环境湿度该如何达到这一标准呢?在工业生产中采取行之有效的加湿措施是必不可少的,随着加湿器的广泛应用,使用正岛ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器来增加空气湿度,并将其保持在最适宜的范围之内,这显然是一个非常简捷而又有效的办法。正岛ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器产品,对于其他加湿方式的加湿器而言,具有【雾化颗粒细】 、【使用能耗低】 、【雾化能效高】,【加湿速度快】的显著优势。正岛电器生产的ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器是采用超声波高频振荡的原理,从而达到均匀加湿的目的;具有空气加湿、净化、防静电、降温、降尘等多种用途;既可以较大空间进行均匀加湿,也可对特殊空间进行局部湿度补偿,具有较高的使用灵活性。点击此处查看智能型超声波加湿器全部新闻图片备注:该系列产品可与环境试验设备以及环境监测仪器等温湿度相关仪器设备配套使用,也可作为其中的一个核心配件!正岛ZS系列超声波工业用加湿器生产厂家:正岛电器,产品优势区别与对比,谨防假冒!备注目前市场部分加湿器厂家仿冒正岛加湿器ZS系列型号低配置低价格在销售请客户区别以下:品 牌电 源风 机外 壳正 岛变频电源 防水等级IP68(低能耗、低故障)特制防水风机全不锈钢外壳及内胆仿冒变压器(高耗能、高故障高、维修频率高)普通风机(易烧毁)普通钣金(易锈)正岛电器郑重承诺:整机保修一年,完善售后服务体系;以质量第一,诚信至上为企业宗旨。欢迎您来电咨询智能型超声波加湿器的详细信息!工业用加湿器种类有很多,不同品牌工业用加湿器价格及应用范围也会有所不同,而我们将会为您提供全方位的售后服务和优质的解决方案。正岛ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器控制方式,技术参数:控制方式加湿量1.8kg/h加湿量3kg/h加湿量6kg/h加湿量9kg/h加湿量12kg/h加湿量18kg/h开关控制ZS-06ZS-10ZS-20ZS-30ZS-40ZS-F60时序控制ZS-06SZS-10SZS-20SZS-30SZS-40SZS-F60S湿度控制ZS-06ZZS-10ZZS-20ZZS-30ZZS-40ZZS-F60Z出雾方式单管单管单管双管双管三管消耗功率180W300W600W900W1200W1500W净重15kg18kg22kg30kg38kg55kg查看更多智能型超声波加湿器的详细信息尽在:正岛电器正岛ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器产品六大核心配置优势:优势一:【全不锈钢箱体】优势二:【集成式雾化器】优势三:【IP68级防水电源】优势四:【轴承式防水风机】优势五:【耐碱酸陶瓷雾化片】优势六:【高精度湿度传感器】工业加湿器厂家记者核心提示:要是工业生产环境中的空气过于干燥,就很容易使静电积累而产生静电感应现象;因此,在寒冷干燥的冬天一些工厂企业在进行各种生产作业时,经常会受到静电的干扰;毫无疑问,静电对各个行业的生产以及产品质量等方面所造成的影响都是很大的;要想确保工业生产的顺利进行,提高产品的生产品质,必须消除静电对其所造成的影响和危害;因此,正岛电器建议你在条件允许的情况下可以通过使用正岛ZS-40Z智能型超声波加湿器及ZS系列超声波工业加湿器来进行合理加湿的方式,使生产环境中能够保持最适宜的湿度,避免出现湿度过低或空气过于干燥的情况,那么静电也就消除了!以上关于智能型超声波加湿器的最新相关新闻报道是正岛电器为大家提供的!您可以在这里更详细地了解智能型超声波加湿器的最新相关信息:静电无时无刻不存在在生活中,那么,你们知道这个防静电的专业术语吗?看看下面的简单分析。 摩擦起电——用摩擦的方法使两物体分别带有等值异号电荷的过程。衰减时间——静电电压从峰值电压降低到给定比例的时间。好比,在15%相对湿度的情况下,静电电压从2000V降低到100V的衰减时间小于等于1秒。屏蔽泄漏电压——因屏蔽体外部的高电场而使屏蔽体内部获得的感应电场电压或外部高电场穿透屏蔽体衰减的残留电场电压,又称屏蔽残余电压。静电中和——带电体上的电荷与其内部和外部相反符号的电荷(电子或离子)的复合而使所带静电部分或全部消失的现象。表面电阻——两个特定的放置于材料同一面的电极之间的电压与它们通过电流的比值。体电阻——单位厚度上的直流电压,与通过材料的单位面积电流的比值,测试电极放置于材料相对面的对应位置。接地电阻——被接地体与地下零电位面之间的接地引线电阻、接地器电阻、接地器与土壤之间的过渡电阻和土壤的溢流电阻之和。以上的几点就是防静电的术语了
  • 3061型智能气体流速测试仪
    产 品 名 称 3061型智能气体流速测试仪 适 用 范 围 本仪器应用皮托管法测量管道中气体流速。可供环保、卫生、劳动、安监、军事、科研、教育等部门用于测量各种锅炉、炉窑以及各种排风管道的气体流速、流量、动压、静压、温度等参数。 执 行 标 准 HJ/T 48-1999 《烟尘采样器技术条件》 技 术 特 点 ◆ 手持式测量仪器,操作方便 ◆ 进口高精度微压差传感器,精度高,温飘小 ◆ 电源采用 5 号电池,无需交流电 ◆ 自动计算保存流速、平均压力、流量等参数 ◆ 自动零点修正,软件校准,保证测量精度 ◆ RS232 数字接口,能外接微型打印机或微机 主 要 指 标 主要参数 参数范围 分 辨 率 准 确 度 动  压 (0~2000)Pa 1Pa 优于± 2.0% 静  压 (-30~+30)kPa 0.01kPa 优于± 2.5% 温  度 (0~500)℃可扩展 0.1℃ 优于± 3℃ 流  速 (5~45)m/s - 优于± 5.0% 电  源 DC6V 连续工作时间 &ge 70小时(与电池性能有关) 体  积 (115× 200× 45)mm 重  量 约0.8kg 功  耗 约0.5W
  • 36门智能型条码电子寄包柜
    36门智能型条码电子寄包柜主要技术参数:外形尺寸:W2301*D430*H1800mm 单柜尺寸:W270*D410*H280mm 开锁方式:密码纸或扫描纸 电 源:220V 50/60 HZ(可使用备用电源,选购) 显 示:128× 64点阵,带背光 功 率:待机10W,工作30W24门智能型条码电子寄包柜主要技术参数:外形尺寸:W1670*D430*H1800mm 单柜尺寸:W270*D410*H280mm 开锁方式:密码纸或扫描纸 电 源:220V 50/60 HZ(可使用备用电源,选购) 显 示:128× 64点阵,带背光 功率:待机10W,工作30W智能型条码电子寄包柜主要技术特点:1.柜体采用1mm及1.2mm优质钢板制作,多处加强结构。表面处理采用先进的有13道工序组成的橘纹烤漆,耐腐蚀性强。 2.机设条码寄存方式,大大缩短了顾客的取物时间,提高了使用效率;同时简化了顾客的取物操作,极大的方便了顾客。 3.采用先进的热敏打印机,打印条码纸,无打印耗材,采用进口切纸刀,自动切断条码纸,安全可靠。 4.采用进口的条码阅读器,识别率高,快速准确;对于被折叠、揉搓过的条码纸(只要条码图形不受损),仍能达到100%的识别率。 5.采用条形码作为取物凭证,提高了凭证的保密性。 6.条码纸上条形码的下方附有其数字代码(字型较小),便于比对记录;同时在条码图形被人为损坏后,仍可通过键盘输入其代码进行取物。 7.采用内置密码键的管理方式进入对寄存柜来说致关安全和可信度的管理界面,需使用专用钥匙并输入密码,才能进行参数设定,应急开门、锁门,查询和打印等操作。 8.友好,明了的用户界面采用点阵式带背光的大屏幕液晶显示屏,为用户和管理者的使用和管理作提示。 9.语言提示提醒用户取密码条和关门。请著名电台主持人录音。 10.红外检测物品功能。提高了物品存放的安全性。 11.有齐全的各种记录备查。 12.同等箱数、同等容积的条件下,空间利用率最高,可大大减少场地占用费用
  • 粉体振实密度测试仪 汇美科LABULK 0335 LABULK 0335-1906040900 全自动智能型
    粉体振实密度测试仪简介LABULK 0335振实密度仪是用来测量粉体振实密度的仪器。该仪器由触屏操作面板、振动组件、电机、打印机、电子天平及量筒组成。根据国际及国内的标准研发的LABULK 0335振实密度仪按照设定好的转速及振实高度进行工作,使振动组件上面安放的盛装干粉样品量筒上下振动,从而测量出该粉体的振实密度。该仪器可以随意设定测量参数,并可以自动测量,自动打印,除振实密度外,还可以自动测出粉体的流动性等指数。广泛用于金属、医药、食品、塑料、矿物等领域。仪器生产厂家与供应商为丹东汇美科仪器有限公司。型号为LABULK0335的振实密度仪采用国际先进的松装测试技术设计制造,仪器的主要参数性能与外国进口设备保持一致,而且该仪器价格合理,汇美科已经成为实验室振实密度分析及仪器采购的SHOU选品牌。技术参数测量特性:振实密度及流动性等装样量:5-250 mL(用户可以随意设定)计时范围:0-99999秒(用户可以随意设定)计数范围:0-99999次(用户可以随意设定)振动高度:3或14 mm振动频率:250或300转/分(用户可以随意设定)仪器尺寸:33x31x18cm(量筒高度未计)电压:220V/50Hz重量:16公斤产品特点新一代智能触屏,通过7英寸LCD显示屏精确控制操作。主机与配件通讯自检功能,让操作者一目了然。测量模式二选一,振实时间或振动次数随意设置测量过程中实时显示操作状态。通过RS-232与电子称相连,实时显示电子称数值。轻轻一触,详细的打印报告呈现眼前应用领域汽车与航空航天生物及药品研发能源及环境食品矿物与金属塑料及聚合物化学品等所有粉末或以颗粒状态存在的物质
  • 低插入损耗单模光纤跳线
    低插入损耗单模光纤跳线特性低插入损耗(典型值):0.3 分贝 (600 - 800 nm)0.5 - 0.6 分贝(405 - 532 nm和488 - 633 nm)0.9 分贝(320 - 430 nm)有效波段范围:320 - 430 nm,405 - 532 nm,488 - 633 nm或是633 -780 nm可选的接头有(皆为2.0 毫米的窄口接头):FC/PCFC/APCFC/PC转FC/APC具有每根跳线单独测试的数据附带两个CAPF防尘帽Thorlabs公司提供两头带有FC/PC或FC/APC接头的低插入损耗单模跳线。此外,我们还提供FC/PC转FC/APC跳线。这些小纤芯跳线由我们自己的工厂中用zui先进的设备进行制造,每一根都经过人工挑选,保证光纤具有很小的公差以及匹配的插芯。它们都经过测试,保证了其低损耗特性。这里提供的跳线设计用于320 - 430 nm,400 - 532 nm,488 -633 nm,或者633 - 780nm光波范围的信号传输,在低插入损耗跳线之间分别具有典型0.9 dB,0.5-0.6 dB或者0.3 dB插入损耗。我们的FC/PC跳线具有较高的50分贝(典型值)回波损耗,FC/APC跳线具有60分贝(典型值)回波损耗。每根光纤跳线的测量性能参数都在其附带的规格表中有详细介绍。在标准跳线中,光纤参数(如纤芯-包层偏心度或纤芯与跳线中心的不对准程度)都会有微小的差异。在使用标准匹配套管对准单模跳线的纤芯时,其小纤芯会使这些差异更加严重,或是导致更高的插入损耗。通过广泛地挑选和测试过程,我们的低插入损耗跳线具有高同心度、对心良好的纤芯,可以极大地减小跳线的插入损耗(请参看对比标签了解更多细节)。生产低插入损耗跳线的流程的di一步是人工挑选纤芯-包层同心度高于典型值、小公差光纤外径的光纤,从而与插芯进行匹配。每个插芯也是通过人工进行挑选,从而使插芯内径与光纤尺寸相匹配,并匹配插芯的纤芯-外径同心度。这样就可以保证光纤能够zui紧凑地被包裹,并具有zui佳同心度,保证低插入损耗性能。插芯经过机器抛光,光纤纤芯与接头插销之间的对准公差为±5度。zui后,跳线的插入损耗通过测试,直到符合you秀跳线的标准。通过人工挑选光纤和插芯,Thorlabs公司的低插入损耗跳线能够具有出色的性能和质量。我们还提供匹配套管用于连接FC转FC、SMA转SMA和FC转SMA接头。这些匹配套管可以将背向反射zui小化,保证每个连接光纤末端的纤芯能够很好地对准。我们特别推荐使用我们更小公差的ADAFCPM2精密PM匹配套管,被用于达到下面说明书提到的插入损耗。每根跳线有两个防尘帽,能够防止插芯末端受到尘土和其它污染物的污染。我们也单独销售保护FC/PC终端CAPF塑料光纤帽和CAPFM金属螺纹光纤帽。Stock Single Mode Patch Cables Selection GuideStandard CablesFC/PC to FC/PCFC/APC to FC/APCHybridAR-Coated Patch CablesHR-Coated Patch CablesBeamsplitter-Coated Patch CablesLow-Insertion-Loss Patch CablesMIR Fluoride Fiber Patch CablesAR-Coated Patch Cables如果您在我们的库存中找不到适合您应用的跳线,Thorlabs公司还提供定制低插入损耗跳线服务。请联系技术支持了解报价。此外,点击下面表格中连接有标准跳线定制且当天发货服务。用我们的Centroc测试设备所测得的结果,显示了标准跳线(左)和低插入损耗跳线(右)的典型纤芯角度对准和同心度。规格:Item # PrefixP1-305P-FCP3-305P-FCP5-305P-FCAPCP1-405P-FCP3-405P-FCP5-405P-FCAPCConnector TypeFC/PCFC/APCFC/PC to FC/APCFC/PCFC/APCFC/PC to FC/APCFiber TypeSM300SM400Operating Wavelength320 - 430 nm405 - 532 nmCutoff Wavelength≤310 nm305 - 400 nmInsertion Loss (Max/Typ.)a1.5 dB / 0.9 dB1.0 dB / 0.5 dB (1 m and 2 m Long Cables)1.0 dB / 0.6 dB (5 m Long Cables)Mode Field Diameter2.0 - 2.4 μm @ 350 nm2.5 - 3.4 μm @ 480 nmKey Width2.0 mm (Narrow)Cable Length Tolerance+0.075/-0.0 mJacket Type?3 mm FT030-YCladding Diameter125 ± 1.0 μmCoating Diameter245 ± 15 μmNumerical Aperture0.12 - 0.14Max Attenuationb≤70 dB/km @ 350 nm≤50 dB/km @ 430 nm≤30 dB/km @ 532 nmOperating Temperature0 to 70 °CStorage Temperature-45 to 85 °C与另一根低插入损耗的光纤跳线配接时的插入损耗值。在405 nm波段下使用低插入损耗的跳线和一个ADAFCPM2匹配套管进行测试。zui大衰减度数据针对无端接头的光纤。Item # PrefixP1-460P-FCP3-460P-FCP5-460P-FCAPCP1-630P-FCP3-630P-FCP5-630P-PCAPCConnector TypeFC/PCFC/APCFC/PC to FC/APCFC/PCFC/APCFC/PC to FC/APCFiber TypeSM450SM600Operating Wavelength488 - 633 nma633 - 780 nmCutoff Wavelength350 - 470 nma500 - 600 nmInsertion Loss (Max/Typ.)b1.0 dB / 0.5 dB (1 m and 2 m Long Cables)1.0 dB / 0.6 dB (5 m Long Cables)0.8 dB / 0.3 dBMode Field Diameter2.8 - 4.1 μm @ 488 nm3.6 - 5.3 μm @ 633 nmKey Width2.0 mm (Narrow)Cable Length Tolerance+0.075/-0.0 mJacket Type?3 mm FT030-YCladding Diameter125 ± 1.0 μmCoating Diameter245 ± 15 μmNumerical Aperture0.10 - 0.14Max Attenuationc≤50 dB/km @ 488 nm≤15 dB/km @ 630 nmdOperating Temperature0 to 70 °CStorage Temperature-45 to 85 °C光纤经过手工挑选,以确保更高的截止波长。在截止波长附近的单模操作需要考虑发射条件。与另一根低插入损耗的光纤跳线配接时的插入损耗值。在488 nm(SM450跳线)或是630 nm(SM600跳线)波段,配合一个ADAFCPM2匹配套管利用另一根低插入损耗的跳线进行测试。zui大衰减度数据针对无端接头的光纤。衰减度是zui差值,针对zui短波长的情况。对比405 纳米跳线对比T上图包含了Thorlabs公司长1米、2米的低插入损耗(LIL)跳线和标准跳线之间的示例对比数据。上述数据下长1米的LIL跳线具有-0.37分贝的平均插入损耗,长2米的LIL跳线具有-0.39分贝的插入损耗,长5米的LIL跳线具有-0.59分贝的插入损耗,而长1米的标准跳线具有-2.48分贝的插入损耗,长2米的标准跳线具有-2.44分贝的插入损耗,长5米的标准跳线具有-2.42分贝的插入损耗。5米跳线所测得的插入损耗稍高,这是因为我们没有对光纤的损耗进行校准。我们的LIL跳线的平均插入损耗与标准跳线相比平均高~7倍。T在测试我们跳线的插入损耗时,我们将波长为405乃的光纤耦合激光光源耦合到精选的跳线中;跳线输出功率经过测试和调节,保证不同跳线的数值基本相同。每根待测光纤经过检查、清洁并连接到匹配套管上,然后记录下跳线的输出功率。这样一来,就可以进行光纤插入损耗的均匀性测量,并与其它跳线的插入损耗进行对比。测试过程如右图所示。损伤阀值激光诱导的光纤损伤以下教程详述了无终端(裸露的)、有终端光纤以及其他基于激光光源的光纤元件的损伤机制,包括空气-玻璃界面(自由空间耦合或使用接头时)的损伤机制和光纤玻璃内的损伤机制。诸如裸纤、光纤跳线或熔接耦合器等光纤元件可能受到多种潜在的损伤(比如,接头、光纤端面和装置本身)。光纤适用的zui大功率始终受到这些损伤机制的zui小值的限制。虽然可以使用比例关系和一般规则估算损伤阈值,但是,光纤的jue对损伤阈值在很大程度上取决于应用和特定用户。用户可以以此教程为指南,估算zui大程度降低损伤风险的安全功率水平。如果遵守了所有恰当的制备和适用性指导,用户应该能够在指定的zui大功率水平以下操作光纤元件;如果有元件并未指定zui大功率,用户应该遵守下面描述的"实际安全水平"该,以安全操作相关元件。可能降低功率适用能力并给光纤元件造成损伤的因素包括,但不限于,光纤耦合时未对准、光纤端面受到污染或光纤本身有瑕疵。关于特定应用中光纤功率适用能力的深入讨论,请联系技术支持。Quick LinksDamage at the Air / Glass InterfaceIntrinsic Damage ThresholdPreparation and Handling of Optical Fibers空气-玻璃界面的损伤空气/玻璃界面有几种潜在的损伤机制。自由空间耦合或使用光学接头匹配两根光纤时,光会入射到这个界面。如果光的强度很高,就会降低功率的适用性,并给光纤造成yong久性损伤。而对于使用环氧树脂将接头与光纤固定的终端光纤而言,高强度的光产生的热量会使环氧树脂熔化,进而在光路中的光纤表面留下残留物。损伤的光纤端面未损伤的光纤端面插芯/接头终端相关的损伤机制有终端接头的光纤要考虑更多的功率适用条件。光纤一般通过环氧树脂粘合到陶瓷或不锈钢插芯中。光通过接头耦合到光纤时,没有进入纤芯并在光纤中传播的光会散射到光纤的外层,再进入插芯中,而环氧树脂用来将光纤固定在插芯中。如果光足够强,就可以熔化环氧树脂,使其气化,并在接头表面留下残渣。这样,光纤端面就出现了局部吸收点,造成耦合效率降低,散射增加,进而出现损伤。与环氧树脂相关的损伤取决于波长,出于以下几个原因。一般而言,短波长的光比长波长的光散射更强。由于短波长单模光纤的MFD较小,且产生更多的散射光,则耦合时的偏移也更大。为了zui大程度地减小熔化环氧树脂的风险,可以在光纤端面附近的光纤与插芯之间构建无环氧树脂的气隙光纤接头。我们的高功率多模光纤跳线就使用了这种设计特点的接头。曲线图展现了带终端的单模石英光纤的大概功率适用水平。每条线展示了考虑具体损伤机制估算的功率水平。zui大功率适用性受到所有相关损伤机制的zui低功率水平限制(由实线表示)。制备和处理光纤通用清洁和操作指南建议将这些通用清洁和操作指南用于所有的光纤产品。而对于具体的产品,用户还是应该根据辅助文献或手册中给出的具体指南操作。只有遵守了所有恰当的清洁和操作步骤,损伤阈值的计算才会适用。安装或集成光纤(有终端的光纤或裸纤)前应该关掉所有光源,以避免聚焦的光束入射在接头或光纤的脆弱部分而造成损伤。光纤适用的功率直接与光纤/接头端面的质量相关。将光纤连接到光学系统前,一定要检查光纤的末端。端面应该是干净的,没有污垢和其它可能导致耦合光散射的污染物。另外,如果是裸纤,使用前应该剪切,用户应该检查光纤末端,确保切面质量良好。如果将光纤熔接到光学系统,用户首先应该在低功率下验证熔接的质量良好,然后在高功率下使用。熔接质量差,会增加光在熔接界面的散射,从而成为光纤损伤的来源。对准系统和优化耦合时,用户应该使用低功率;这样可以zui大程度地减少光纤其他部分(非纤芯)的曝光。如果高功率光束聚焦在包层、涂覆层或接头,有可能产生散射光造成的损伤。高功率下使用光纤的注意事项一般而言,光纤和光纤元件应该要在安全功率水平限制之内工作,但在理想的条件下(ji佳的光学对准和非常干净的光纤端面),光纤元件适用的功率可能会增大。用户首先必须在他们的系统内验证光纤的性能和稳定性,然后再提高输入或输出功率,遵守所有所需的安全和操作指导。以下事项是一些有用的建议,有助于考虑在光纤或组件中增大光学功率。要防止光纤损伤光耦合进光纤的对准步骤也是重要的。在对准过程中,在取得zui佳耦合前,光很容易就聚焦到光纤某部位而不是纤芯。如果高功率光束聚焦在包层或光纤其它部位时,会发生散射引起损伤使用光纤熔接机将光纤组件熔接到系统中,可以增大适用的功率,因为它可以zui大程度地减少空气/光纤界面损伤的可能性。用户应该遵守所有恰当的指导来制备,并进行高质量的光纤熔接。熔接质量差可能导致散射,或在熔接界面局部形成高热区域,从而损伤光纤。连接光纤或组件之后,应该在低功率下使用光源测试并对准系统。然后将系统功率缓慢增加到所希望的输出功率,同时周期性地验证所有组件对准良好,耦合效率相对光学耦合功率没有变化。由于剧烈弯曲光纤造成的弯曲损耗可能使光从受到应力的区域漏出。在高功率下工作时,大量的光从很小的区域(受到应力的区域)逃出,从而在局部形成产生高热量,进而损伤光纤。请在操作过程中不要破坏或突然弯曲光纤,以尽可能地减少弯曲损耗。用户应该针对给定的应用选择合适的光纤。例如,大模场光纤可以良好地代替标准的单模光纤在高功率应用中使用,因为前者可以提供更佳的光束质量,更大的MFD,且可以降低空气/光纤界面的功率密度。阶跃折射率石英单模光纤一般不用于紫外光或高峰值功率脉冲应用,因为这些应用与高空间功率密度相关。320 - 430 nm低插入损耗单模光纤跳线Item #ConnectorsFiberTypeInsertion Loss(Max/Typ.)aOperatingWavelengthCutoffWavelengthMode FieldDiameterMaxAttenuationbNAJacketLengthP1-305P-FC-1FC/PCSM3001.5 dB/0.9 dB320 - 430 nm≤310 nm2.0 - 2.4 μm @ 350 nm≤70 dB/km @ 350 nm0.12 -0.14FT030-Y1mP1-305P-FC-22mP3-305P-FC-1FC/APC1mP3-305P-FC-22mP5-305P-PCAPC-1FC/PC to FC/APC1ma. 与另一低插入损耗光纤跳线配接时的插入损耗值。将低插入损耗单模跳线在405 nm波长下,搭配ADAFCPM2匹配套管进行测试。b. zui大衰减度数据针对的是无端接头的光纤。产品型号公英制通用P1-305P-FC-1低插入损耗单模光纤跳线,1米长,320 - 430 nm, FC/PC接头P1-305P-FC-2低插入损耗单模光纤跳线,2米长,320 - 430 nm,FC/PC接头P3-305P-FC-1低插入损耗单模光纤跳线,1米长,320 - 430 nm,FC/APC接头P3-305P-FC-2低插入损耗单模光纤跳线,2米长,320 - 430 nm,FC/APC接头P5-305P-PCAPC-1低插入损耗单模光纤跳线,1米长,320 - 430 nm,FC/PC转FC/APC接头405 - 532 nm低插入损耗单模光纤跳线Item #ConnectorsFiberTypeInsertion Loss(Max/Typ.)aOperatingWavelengthCutoffWavelengthMode FieldDiameterMaxAttenuationb,cNAJacketLengthP1-405P-FC-1FC/PCSM4001.0 dB/0.5 dB405 - 532 nm305 - 400 nm2.5 - 3.4 μm @ 480 nm≤50 dB/km @ 430 nm≤30 dB/km @ 532 nm0.12 -0.14FT030-Y1mP1-405P-FC-22mP1-405P-FC-51.0 dB/0.6dB5mP3-405P-FC-1FC/APC1.0 dB/0.5 dB1mP3-405P-FC-22mP3-405P-FC-51.0 dB/0.6dB5mP5-405P-FC-1FC/PC to FC/APC1.0 dB/0.5 dB1ma. 与另一低插入损耗光纤跳线配接时的插入损耗值。将低插入损耗单模跳线在405 nm波长下,搭配ADAFCPM2匹配套管进行测试。b. zui大衰减度数据针对的是无端接头的光纤。c. 所述的衰减度是zui差情况的值,针对的是zui短设计波长。产品型号公英制通用P1-405P-FC-1低插入损耗单模光纤跳线,长1米,405 - 532纳米,FC/PCP1-405P-FC-2低插入损耗单模光纤跳线,长2米,405 - 532 nm,FC/PC接头P1-405P-FC-5低插入损耗单模光纤跳线,长5米,405 - 532 nm,FC/PC接头P3-405P-FC-1低插入损耗单模光纤跳线,长1米,405 - 532纳米,FC/APCP3-405P-FC-2低插入损耗单模光纤跳线,长2米,405 - 532纳米,FC/APCP3-405P-FC-5低插入损耗单模光纤跳线,长5米,405 - 532纳米,FC/APCP5-405P-PCAPC-1低插入损耗单模光纤跳线,长1米,405 - 532纳米,FC/PC转FC/APC接头488 - 633 nm低插入损耗单模光纤跳线Item #ConnectorsFiberTypeInsertion Loss(Max/Typ.)aOperatingWavelengthCutoffWavelengthMode FieldDiameterMaxAttenuationb,cNAJacketLengthP1-460P-FC-1FC/PCSM4501.0 dB/0.5 dB488 - 633 nm350 - 470 nm2.8 - 4.1μm @ 488nm≤50 dB/km @ 488 nm0.10 -0.10 -0.14FT030-Y1mP1-460P-FC-22mP1-460P-FC-51.0 dB/0.6dB5mP3-460P-FC-1FC/APC1.0 dB/0.5 dB1mP3-460P-FC-22mP3-460P-FC-51.0 dB/0.6dB5mP5-460P-FC-1FC/PC to FC/APC1.0 dB/0.5 dB1ma. 与另一根低插入损耗的光纤跳线配接时的插入损耗值。在488 nm波长下使用低插入损耗单模跳线和一个ADAFCPM2匹配套管进行测试。b. 手选光纤来保证更高的截止波长。对于截止波长附近的单模操作,需考虑发射条件。c. zui大衰减数据针对无端接头的光纤。产品型号公英制通用P1-460P-FC-1低插入损耗单模光纤跳线,长1米,488 - 633纳米,FC/PCP1-460P-FC-2低插入损耗单模光纤跳线,长2米,488 - 633 nm,FC/PC接头P1-460P-FC-5低插入损耗单模光纤跳线,长5米,488 - 633 nm,FC/PC接头P3-460P-FC-1低插入损耗单模光纤跳线,长1米,488 - 633纳米,FC/APCP3-460P-FC-2低插入损耗单模光纤跳线,长2米,488 - 633纳米,FC/APCP3-460P-FC-5低插入损耗单模光纤跳线,长5米,488 - 633纳米,FC/APCP5-460P-PCAPC-1低插入损耗单模光纤跳线,长1米,488 - 633纳米,FC/PC转FC/APC接头633 - 780 nm低插入损耗单模光纤跳线Item #ConnectorsFiberTypeInsertion Loss(Max/Typ.)aOperatingWavelengthCutoffWavelengthMode FieldDiameterMaxAttenuationb,cNAJacketLengthP1-630P-FC-1FC/PCSM6000.8 dB/0.3 dB633 - 780 nm500 - 600 nm3.6 - 5.3 μm @ 633 nm≤15 dB/km @ 630 nm0.10 -0.10 -0.14FT030-Y1mP1-630P-FC-22mP1-630P-FC-55mP3-630P-FC-1FC/APC1mP3-630P-FC-22mP3-630P-FC-55mP5-630P-FC-1FC/PC to FC/APC1ma. 与另一低插入损耗的光纤配接时的插入损耗。在630 nm波长下将低插入损耗单模跳线搭配ADAFCPM2匹配套管进行测试。b. 波长范围是截止波长和光纤不再传输的边缘波长之间的光谱区域,它表示光纤以低衰减度传输TEM00模的区域。对于这种光纤,边缘波长通常比截止波长长200nm。c. 衰减度是zui差情况的值,针对的是zui短波长。zui大衰减度数据针对的是无端接头的光纤。d. 衰减度是zui差情况的值,针对的是zui短波长。产品型号公英制通用P1-630P-FC-1低插入损耗单模光纤跳线,长1米,633- 780纳米,FC/PCP1-630P-FC-2低插入损耗单模光纤跳线,长2米,633 - 780 nm,FC/PC接头P1-630P-FC-5低插入损耗单模光纤跳线,长5米,633 -780 nm,FC/PC接头P3-630P-FC-1低插入损耗单模光纤跳线,长1米,633 - 780纳米,FC/APCP3-630P-FC-2低插入损耗单模光纤跳线,长2米,633 - 780纳米,FC/APCP3-630P-FC-5低插入损耗单模光纤跳线,长5米,633 - 780纳米,FC/APCP5-630P-PCAPC-1低插入损耗单模光纤跳线,长1米,633 - 780纳米,FC/PC转FC/APC接头
  • 粉末振实密度测试仪 汇美科LABULK 0335 LABULK 0335-1906041431 全自动智能型
    粉末振实密度测试仪简介LABULK 0335振实密度仪是用来测量粉体振实密度的仪器。该仪器由触屏操作面板、振动组件、电机、打印机、电子天平及量筒组成。根据国际及国内的标准研发的LABULK 0335振实密度仪按照设定好的转速及振实高度进行工作,使振动组件上面安放的盛装干粉样品量筒上下振动,从而测量出该粉体的振实密度。该仪器可以随意设定测量参数,并可以自动测量,自动打印,除振实密度外,还可以自动测出粉体的流动性等指数。广泛用于金属、医药、食品、塑料、矿物等领域。仪器生产厂家与供应商为丹东汇美科仪器有限公司。型号为LABULK0335的振实密度仪采用国际先进的松装测试技术设计制造,仪器的主要参数性能与外国进口设备保持一致,而且该仪器价格合理,汇美科已经成为实验室振实密度分析及仪器采购的品牌。技术参数测量特性:振实密度及流动性等装样量:5-250 mL(用户可以随意设定)计时范围:0-99999秒(用户可以随意设定)计数范围:0-99999次(用户可以随意设定)振动高度:3或14 mm振动频率:250或300转/分(用户可以随意设定)仪器尺寸:33x31x18cm(量筒高度未计)电压:220V/50Hz重量:16公斤产品特点新一代智能触屏,通过7英寸LCD显示屏精确控制操作。主机与配件通讯自检功能,让操作者一目了然。测量模式二选一,振实时间或振动次数随意设置测量过程中实时显示操作状态。通过RS-232与电子称相连,实时显示电子称数值。轻轻一触,详细的打印报告呈现眼前应用领域汽车与航空航天生物及药品研发能源及环境食品矿物与金属塑料及聚合物化学品等所有粉末或以颗粒状态存在的物质
  • 940 智能型IC仪器 2.940.1340
    940 Professional IC Vario ONE/ChS/PP/HPG订货号: 2.940.1340940 Professional IC Vario ONE/ChS/PP/HPG 是智能型 IC 仪器,带有化学抑制、蠕动泵用于抑制器再生,以及二元高压梯度。 可使用 942 Extension Modul 将其扩展至四元梯度系统。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度应用,用于阴离子测定,带化学抑制。
  • 940 智能型 IC 仪器 2.940.1110
    940 Professional IC Vario ONE/Prep 1订货号: 2.940.1110940 Professional IC Vario ONE/Prep 1 是智能型 IC 仪器,无抑制,可与万通英蓝样品前处理以及英蓝超滤或英蓝渗析组合使用。 该仪器可使用各种分离和检测方法。典型的应用范围:测定阴离子和阳离子,英蓝超滤或英蓝渗析之后无抑制。英蓝超滤或英蓝渗析之后的 UV/VIS 应用。英蓝超滤或英蓝渗析之后使用电流检测的应用。
  • 940 智能型 IC 仪器 2.940.1120
    940 Professional IC Vario ONE/Prep 2 订货号: 2.940.1120940 Professional IC Vario ONE/Prep 2 是智能型 IC 仪器,无抑制,与万通英蓝样品前处理以及英蓝英蓝基质消除或英蓝校正联用。 该仪器可使用各种分离和检测方法。典型的应用范围:阴离子或阳离子测定,英蓝基质消除之后无抑制。使用英蓝校正进行阳离子超痕量分析。
  • 940 智能型IC仪器 2.940.1530
    940 Professional IC Vario ONE/SeS/PP/Prep 3订货号: 2.940.1530940 Professional IC Vario ONE/SeS/PP/Prep 3 是智能型 IC 仪器,带有序列抑制,带蠕动泵用于抑制器再生,与万通英蓝样品前处理以及英蓝中和或英蓝阳离子消除组合使用。 该仪器可使用各种分离和检测方法。典型的应用范围:序列抑制法阴离子测定,英蓝中和。在线痕量分析,带英蓝中和以及之后的 MiPCT-ME。在过渡金属浓度较高的样品(例如电镀池)中消除阳离子后进行阴离子分析。
  • 940 智能型双通道IC仪器 2.940.2100
    940 Professional IC Vario TWO订货号: 2.940.2100940 Professional IC Vario TWO 是智能型双通道 IC 仪器,无抑制。 该仪器可使用各种分离和检测方法。典型的应用范围:双通道应用,无抑制,用于测定阴离子、阳离子、碳水化合物或极性有机物。与电导、UV-VIS 或安培检测组合使用。
  • FTE5000 损耗测试仪 带ORL和视频探头
    FTE5000 损耗测试仪 带ORL和视频探头The FTE-5000combines four functions for testing optical networks together in one unit. It brings together a -55dB ORL meter, power meter, laser source and video scope capability with IEC61300-3-35 method “B” Pass/Fail End face Grading Map (probe sold separately).The FTE-5000 is a full featured ORL Loss Test Set. It has 4” super bright color touch screen display with large easy to read characters. It performs optical return loss measurements to -55db at up to three wavelengths and is an automated loss test set with dual or triple wave Light sources. The power meter uses an InGaAs detector which is calibrated at 850,1300, 1310, 1490, 1550 and 1625nm, with a dynamic range of -77dBm. These units are available in single, dual, triple or quad wavelength configurations and displays measurements up to three wavelengths at one time. In the Autotest mode, the master unit changes wavelengths at a fixed rate and informs the slave unit of the wavelength currently being measured. Use this method to test up to three wavelengths at a time and store the loss measurements for each of the lasers fired during the test. Up to 5000 tests may be stored and recalled via the unit’s USB port. Use TTI’s CertSoft PC application software for downloading stored data and organizing the information or use the Android Bluetooth virtual instrument application for remote operation.The information from OTDR, LTS, ORL and video scope may be combined to offer a comprehensive report for all of your network testing needs.The FTE-5000 also includes a video scope (probe sold separately). Use the video scope to ensure the integrity and cleanliness of the connectors being tested. Use the modulation feature to perform fiber identification function. The power meter will identify modulated signals at 270, 1000 and 2000 Hz produced a modulate light source.Features?Optical Loss/ORL Tester?ORL Measurement Range to -55 dB?PM with -77 dBm Dynamic Range?IEC61300-3-35 method “B” Video Scope(Probe Sold Separately)?Auto Test Up To Three Wavelengths?Automated Loss Measurements?Auto Wavelength Switching?Universal PM and LS Adapters?Storage for 5,000 Test?Bright Color Display?Rechargeable NiMH Batteries?USB Interface?Free Report Software?On-Board Help FeatureOrdering InformationFTE-5000-8513LTS with 850/1300nm Light Source and Video Scope (Probe Sold Separately)FTE-5000-1315LTS with 1310/1550nm Light Source and Video Scope (Probe Sold Separately)FTE-5000-345LTS with 1310/1490/1550nm Light Source and Video Scope (Probe Sold Separately)FTE-5000-QUADLTS with 850/1300/1310/1550nm Light Source (No Video Scope Capability)VIS300Video Probe for use with FTE-7000, FTE-1700 and FTE-5000 seriesGeneral SpecificationsDisplay4 in Color TFTStorage Locations5000Battery/Operating Time4 AA Rechargeable NiMH / 6 hrsPower RequirementsWall Mount, Universal 100-240V47-63 Hz 9 VDC Center Positivewith, US, UK, Continental Europe, and Australian PlugsOperating Temperature Range-10 to 45 CDimensions(w/o rubber boot )7.62” L x 3.88” W x 1.56” H(194mm L x 99mm W x 40mm H)Weight0.52 KgAccessories ProvidedFC, ST, SC adaptors for both Power Meter and Light Source, rubber boot, battery,power supply/charger, manual and software on CD and USB cablePower Meter SpecificationsDetector TypeInGaAsConnector Type2.5mm InterchangeableDynamic Range+5 to -77dB (CATV - +25 to -57dB)Auto Test Range0 to -40dBCalibrated Wavelengths850,1300,1310,1490,1550,1625nmUnits of MeasurementdBm, dB, mW, μW and nWPower Measurement Uncertainty± 0.18 dB under reference conditions, ± 0.25 dB from 0 to -65 dBm,± 0.35 dB from 0 to +5 dBm and from -65 to -77 dBmUnits of MeasurementdBm, dBResolution.01 dBModulation Modes DetectedCW, 270 Hz, 1000 Hz, 2000 HzLight Source SpecificationsFiber TypeSingle Mode, MultimodeWavelengths Available850,1300,1310,1490,1550 and 625 nm ±20nmas Unit is EquippedOutput Power0 dBm, 1mw(-3dBm @ 1625nm)Output Stability± .05 dB / 24 hrs @ constant temp,, ± .02 dB/C temperature coefficientLaser Safety ClassificationClass I Safety Per FDA/CDRH and IEC-825-1 RegulationModulation ModesCW, 270 Hz, 1000 Hz, 2000 HzSpectral WidthORL MeterOptical Return Loss Dynamic Range0-55 dBORL WavelengthsSM Source WavelengthsOptical Return Loss Accuracy± 1dB @ -40db reflectionResolution0.01 dB
  • 940 智能型双通道离子色谱仪器 2.940.2400
    940 Professional IC Vario TWO/SeS订货号: 2.940.2400940 Professional IC Vario TWO/SeS 是智能型双通道离子色谱仪器,带序列抑制(单通道)。可使用一台 800 Dosino 用于抑制器再生。该仪器可使用各种分离和检测方法。典型的应用范围:并行测定阴离子和阳离子的标准仪器。阴离子和阳离子的痕量分析。阴离子和阳离子的在线监控。
  • 940 智能型离子色谱仪器 2.940.1200
    940 Professional IC Vario ONE/ChS订货号: 2.940.1200940 Professional IC Vario ONE/ChS 是智能型 IC 仪器,带化学抑制。 可使用一台 800 Dosino 用于抑制器再生。 该仪器可使用各种分离和检测方法。典型的应用范围:使用化学抑制和电导检测进行阴离子测定。用离子排斥色谱法和反向抑制测定有机酸。
  • 940智能型离子色谱仪器 2.940.1410
    940 Professional IC Vario ONE/SeS/Prep 1订货号: 2.940.1410940 Professional IC Vario ONE/SeS/Prep 1 是智能型离子色谱仪器,带序列抑制与万通英蓝样品前处理以及英蓝超滤或英蓝渗析组合使用。可使用一台 800 Dosino 用于抑制器再生。该仪器可使用各种分离和检测方法。典型的应用范围:阴离子或阳离子测定,英蓝超滤或英蓝渗析之后序列抑制法。
  • 940 智能型离子色谱仪器 2.940.1420
    940 Professional IC Vario ONE/SeS/Prep 2订货号: 2.940.1420940 Professional IC Vario ONE/SeS/Prep 2 是智能型离子色谱仪器,带有序列抑制与万通英蓝样品前处理以及英蓝基质消除或英蓝校正组合使用。可使用一台 800 Dosino 用于抑制器再生。该仪器可使用各种分离和检测方法。典型的应用范围:阴离子或阳离子测定,英蓝基质消除之后序列抑制法。使用英蓝校正进行阴离子或阳离子超痕量分析。
  • 940 智能型离子色谱仪器 2.940.1450
    940 Professional IC Vario ONE/SeS/LPG订货号: 2.940.1450940 Professional IC Vario ONE/SES/LPG 是智能型离子色谱仪器,带有序列抑制和低压梯度。可使用一台 800 Dosino 用于抑制器再生。该仪器可使用各种分离和检测方法。典型的应用范围:用于阴离子或阳离子测定的梯度应用,序列抑制法。
  • 940 智能型离子色谱仪器 2.940.1510
    940 Professional IC Vario ONE/SeS/PP/Prep 1订货号: 2.940.1510940 Professional IC Vario ONE/SeS/PP/Prep 1 是智能型离子色谱仪器,带有序列抑制和蠕动泵用于抑制器再生,与万通英蓝样品前处理以及英蓝超滤或英蓝渗析组合使用。该仪器可使用各种分离和检测方法。典型的应用范围:阴离子或阳离子测定,英蓝超滤或英蓝渗析之后序列抑制法。
  • TDR阻抗测试仪探头特性阻抗测试仪探头BT-D100
    1.信号稳定,测试误差小。2.可适用高带宽阻抗测试仪阻抗条测试,损耗较小。适用于多种阻抗测试仪
  • 940 智能型 IC仪器 2.940.1240
    940 Professional IC Vario ONE/ChS/HPG订货号: 2.940.1240940 Professional IC Vario ONE/ChS/HPG 是智能型 IC 仪器,带化学抑制和二元高压梯度。 可使用 942 Extension Modul 将其扩展至四元梯度系统。 可使用一台 800 Dosino 用于抑制器再生。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度应用,用于阴离子测定,带化学抑制。
  • 940 智能型IC仪器 2.940.1250
    940 Professional IC Vario ONE/ChS/LPG订货号: 2.940.1250940 Professional IC Vario ONE/ChS/LPG 是智能型 IC 仪器,带化学抑制和低压梯度。 可使用一台 800 Dosino 用于抑制器再生。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度应用,用于阴离子测定,带化学抑制。
  • 940 智能型IC仪器 2.940.1350
    940 Professional IC Vario ONE/ChS/PP/LPG订货号: 2.940.1350940 Professional IC Vario ONE/ChS/PP/LPG 是智能型 IC 仪器,带有化学抑制、蠕动泵用于抑制器再生,以及低压梯度。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度应用,用于阴离子测定,带化学抑制。
  • 940 是智能型 IC 仪器 2.940.1550
    940 Professional IC Vario ONE/SeS/PP/LPG 订货号: 2.940.1550940 Professional IC Vario ONE/SES/PP/LPG 是智能型离子色谱仪器,带有序列抑制、蠕动泵用于抑制器再生、以及低压梯度。该仪器可使用各种分离和检测方法。典型的应用范围:用于阴离子或阳离子测定的梯度应用,序列抑制法。
  • 940 智能型IC仪器 2.940.1140
    940 Professional IC Vario ONE/HPG订货号: 2.940.1140940 Professional IC Vario ONE/HPG 是智能型 IC 仪器,无抑制,带二元高压梯度。 可使用 942 Extension Modul 将其扩展至四元梯度系统。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度淋洗后使用脉冲安培检测法(PAD)分析碳水化合物。使用 UV/VIS 检测的梯度应用,带或不带柱后衍生反应。
  • 940 智能型IC仪器 2.940.1150
    940 Professional IC Vario ONE/LPG订货号: 2.940.1150940 Professional IC Vario ONE/LPG 是智能型 IC 仪器,无抑制带低压梯度。 该仪器可使用各种分离和检测方法。典型的应用范围:梯度淋洗后使用脉冲安培检测法(PAD)分析碳水化合物。使用 UV/VIS 检测的梯度应用,带或不带柱后衍生反应。
  • AOI 45deg 超高低损耗反射镜 1500-1600nm
    损耗极低的激光光学器件,对于要求极低损耗的镀膜光学器件应用, 筱晓光子可提供R 99.995 %、总损失小于10 ppm的反射镜。此类超级反射镜片可用于环形激光器陀螺仪组件或光腔衰荡应用。对超抛光基材加工低吸收、低散射镀膜时,我们会采用改进型IBS镀膜机。而为了保证清洁度,此类机器会存放在专用的超清洁室内,并且与生产相关的基材预处理和后期处理流程全部在此清洁室内完成。 此外,超清洁室内还配置有多种测量设备,如检测流程所使用的白光表面光度仪和高分辨率显微镜。利用定制光腔衰荡设置可以确定反射量(精度可达小数点后四位)以及损耗。 而测定以上数值必须使用表面粗糙度小于 1 ? rms的超抛光基材。为了保证反射镜成品的品质,还会使用白光表面光度仪进行质量检测中心波长1572nm技术参数产品特点:低损耗可定制不同尺寸入射角:0deg/45deg可选 应用领域:TDLAS光腔衰荡基材以及镀膜参数:材质红外级熔融石英 Infrasil形状圆形直径(?)12.7,25.4 mm ,50.8(-0.1 mm)厚度(t)6.35 mm (±0.1 mm)边缘厚度6.35 mm平行度5? 光学参数 正面(S2)光学参数 背面(S1)形状凹面形状平面曲率半径1,000 mm (±1 %)倒角0.3 mm (±0.1 mm)倒角0.3 mm (±0.1 mm)测试区 ?e20测试区 ?e20曲面容差3/0.2(0.2) [L/10 @546.1nm]曲面容差3/-(0.2) [L/10 reg. @546.1nm]清洁度5/2x0.04 L1x0.004清洁度5/2x0.04 L1x0.004 内部测试区?e 10清洁度 5/2x0.0161st 工作范围 高反射(45°,15572nm)99.995%1st 工作范围 减反射(0°,1450-1650nm)0.2%类别:高反射率偏振:unpol.入射角 45°波长范围:1572 nm高反射 99.995 %类别 减反射偏振 unpol.入射角 0°波长范围 1450 - 1650 nm AR / HT 0.2 %2nd 工作范围 T(0°,1550nm)~0.005%类别:透射率偏振: unpol.入射角 45°波长范围:1550 nmHT ~ 0.005 % 镀膜曲线:HRs,p(45°,1570-1580nm)99.995%
  • 红外(IR)薄膜分束器/低损耗镀膜激光偏振器
    红外 (IR) 薄膜分束器Ø3 - 5µm 的平均 R/T 比为 45/55Ø没有来自第二表面反射的重影Ø消除光束位移Ø还提供用于 VIS-NIR 的薄膜分束器红外 (IR) 薄膜分束器采用安装在铝制框架中的薄硝化纤维素分束膜,设计为具有 3 - 5µm 的 45R/55T 分束比。 薄硝酸纤维素膜消除了第二表面反射和光束位移,同时最大限度地减少了光路长度的变化。 铝制框架在框架下侧具有安装孔,便于安装和集成到 OEM 系统中。红外 (IR) 薄膜分束器是 MWIR 应用的理想选择,包括 MWIR 成像、红外光谱、火焰检测和红外探测器的一般用途。注意:这些分束器的硝化纤维膜非常薄且易碎。 不得接触膜,只能使用空气进行清洁。 我们建议使用鼓风机,因为来自压缩空气的力可能会损坏膜。通用规格基材:Nitrocellulose反射/透射比 (R/T):45/55波长范围 (nm):3000 - 5000镀膜:Dielectric镀膜规格:45/55 @ 3000 - 5000nm构造 :Pellicle外壳:Black Anodized Aluminum折射率 nd:1.5表面质量:40-20厚度 (μm):2 +0.3/-0.2产品型号Dia. (mm)CA (mm)产品编码19.0512.7#19-28034.9025.4#19-28163.5050.8#19-28288.9076.2#19-283114.30101.6#19-284165.10152.4#19-285技术数据低损耗 IBS 镀膜激光偏振器Ø1064nm Nd:YAG 设计波长Ø在 45° AOI 具有 10,000:1 的高消光比Ø低损耗离子束溅射 (IBS) 镀膜Ø采用 10-5 表面质量的 UV 熔融石英基片低损耗 IBS 镀膜激光偏振器用于传输 p 偏振光,同时反射 s 偏振光,消光比高达 10000:1。这些偏振器具有离子束溅射 (IBS) 镀膜,设计用于在 45° 入射角下实现最佳的低损耗性能。它们由紫外熔融石英基片制成,与高功率激光器一起使用时可将热效应降至低,并且具有 10-5 的激光级表面质量。低损耗 IBS 涂层薄膜激光偏振器非常适合与 1064nm Nd:YAG 激光器一起使用,以分离或组合 s 偏振和 p 偏振激光。如果您的应用需要具有定制尺寸、镀膜或其他激光应用要求的低损耗 IBS镀膜激光偏振器,请与我们联系。注意:这些光学元件边缘上的箭头指向薄膜偏振片镀膜。产品型号DWL (nm)消光比CA (mm)表面质量Dia. (mm)厚度 (mm)产品编码106410,000:12010-525.406.35#16-747爱特蒙特光学® F-Theta 透镜Ø激光扫描应用的理想选择Ø扫描场上的衍射受限,波前误差低Ø长工作距离和大扫描区域Ø还提供振镜、扩束器和激光源Edmund Optics® F-Theta 透镜旨在在扫描系统的图像平面提供平场,并与检流计、扩束器和激光源结合使用。 这些 F-Theta 透镜具有紧凑的外形,提供高达 273 毫米的各种焦距和高达 164 毫米 (X) x 164 毫米 (Y) 的大扫描场。 这些透镜针对常见的光纤激光源和 Nd:YAG 基波或二次谐波进行了优化,设计波长为 532nm 和 1064nm,具有通用安装螺纹,可轻松集成到振镜系统中。 爱特蒙特光学® F-Theta 透镜是用于激光扫描和激光加工应用(包括激光打标、雕刻、切割、钻孔和 3D 建模)的经济高效的解决方案。产品型号DWL (nm)扫描角 (°)扫描场 (mm)类型WD (mm)产品编码532±22.6856.5 x 56.5F-Theta Lens94.5#15-185532±25.00101.8 x 101.8F-Theta Lens193.5#15-1861064±18.6035.4 x 35.4F-Theta Lens72.1#15-1781064±22.6856.5 x 56.5F-Theta Lens107.9#15-1791064±22.6286.0 x 86.0F-Theta Lens171.2#15-1801064±28.50116.2 x 116.2F-Theta Lens188.1#15-1811064±25.00157.0 x 157.0F-Theta Lens304.6#15-1821064±24.10164.0 x 164.0F-Theta Lens313.0#15-183光散射膜Ø散射 UV 到 NIR 范围的照明光线Ø柔性聚合物基片Ø易于根据尺寸进行切割Ø另外提供玻璃散射片L光散射膜由 TAC 聚合物材料制成,可对 UV 到 NIR 范围的照明光线提供散射。可以轻松地根据尺寸对这种薄膜进行切割,以满足应用要求,可以使用轻松地根据尺寸对这种薄膜进行切割,以满足应用要求,可以使用光学胶粘剂将其粘附到玻璃表面。光散射膜非常适用于机器视觉、视觉检测和自动检测应用,以散射LED 光源,从而产生无热点的均匀照明。若您的应用需要自定义尺寸的光散射膜,或需要将光散射膜层压到光学组件(例如光学窗口片、有色玻璃和聚合物偏振片)上,请联系我们。通用规格涂层:Uncoated厚度 (mm):0.13 ±0.005波长范围 (nm):300 - 1100注意:Protective film on both surfaces should be removed before use产品型号涂层尺寸 (mm)产品编码Uncoated100 x 100#17-683Uncoated300 x 300#17-682技术数据E 系列无边缘运动光学反射镜安装座Ø用于安装分光镜和透射式光学元件的 120° 无边缘Ø价格实惠Ø对实验和 OEM 系统不可或缺的安装座E 系列无边缘运动光学反射镜安装座可提供许多对于研发、原型制造和系统集成领域的应用而言不可或缺的功能。这些安装座具有 120° 切口,非常适用于安装分光镜和透射式光学元件,若以 45° 角安装,还能容纳更宽的光束路径。两个 M6 x 0.25 (101.6 TPI) 调节螺丝可提供平稳的移动,可以通过手或内六角扳手(扳手大小 2mm)驱动,以实现翻转和倾斜的光学调整与对齐 (±3.5°)。可以拆卸调节螺丝旋钮,从而使外形更紧凑。E 系列无边缘运动光学反射镜安装座具有安装孔,这些孔是埋头孔(设计目的为容纳 M4 或 8-32 安装硬件)和 M6 x 1.0 内螺纹孔(用于提高安装的多用性,以及与TECHSPEC® 公制不锈钢安装接杆和底座接杆的直接兼容性)。通用规格光学类型:Circular调节螺丝数目:2构造 :Aluminum Plates, Stainless Steel Screws, and Brass Thread BushingsMin. Thickness of Compatible Optics (mm):2微倾斜角度 (°) :±3.5微翻转角度 (°) :±3.5调节螺丝螺距 (mm):0.25Compatible Post:M6 x 1.0, M4 x 0.7, 8-32产品型号兼容光学大小 (mm)Optical Axis Height产品编码12.5/12.725.40#17-27825/25.425.40#17-27950/50.838.10#17-280
  • 940 智能型离子色谱仪器 2.940.1520
    940 Professional IC Vario ONE/SeS/PP/Prep 2订货号: 2.940.1520940 Professional IC Vario ONE/SeS/PP/Prep 2 是智能型离子色谱仪器,带有序列抑制和蠕动泵用于抑制器再生,与万通英蓝样品前处理以及英蓝基质消除或英蓝校正组合使用。该仪器可使用各种分离和检测方法。典型的应用范围:阴离子或阳离子测定,英蓝基质消除之后序列抑制法。阴离子或阳离子超痕量分析,序列抑制法和英蓝校正。
  • SVS智能型热线风速测量探头
    SVS智能型热线风速测量探头(配C310风速仪)法国凯茂SVS智能型热线风速测量探头(配C310风速仪)法国凯茂SVS智能型热线风速测量探头(配C310风速仪)法国凯茂
Instrument.com.cn Copyright©1999- 2023 ,All Rights Reserved版权所有,未经书面授权,页面内容不得以任何形式进行复制