恩德斯豪斯数字式pH电极 Memosens CPS71E
产品参数测量原理玻璃电极应用Process technology and monitoring of processes with:• Rapidly changing pH values• High proportion of electrode poisons such as H2S特点Digital pH electrode for chemical process with an ion trap for poison-resistant reference测量范围Application B:• pH: 0 to 14Application H:• pH: 0 to 12测量原理Gel compact electrode with ceramic junction and ion trap设计All shaft lengths with temperature sensorAdvanced gel technology材质Sensor shaft: Glass to suit processpH membrane glass: Type B, Type NMetal lead: Ag/AgClOpen aperture: Ceramic junction, zirconium dioxideO-ring: FKMProcess coupling: PPS fiber-glass reinforcedNameplate: Ceramic metal oxide外形尺寸Diameter: 12 mm (0.47 inch)Shaft lengths: 120, 225, 360 and 425 mm(4.72, 8.86, 14.2 and 16.7 inch)过程温度1 to 140 °C (32 to 284 °F)过程压力0,8 to 14 bar (11,6 to 203 psi) (absolute)温度传感器NTC 30k防爆认证With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use inhazardous areas Zone 0, Zone 1 and Zone 2.连接Inductive, contactless connection head with Memosens 2.0 technology防护等级IP68其他证书其他证书应用领域Memosens CPS71E电极特别适合严苛工况应用。自带独一无二的抗污型参比系统,采用防潮防水设计,能够可靠测量重度污染介质、强酸和强碱等腐蚀性介质。CPS71E电极采用Memosens 2.0数字技术,支持扩展数据存储,保存标定参数和过程参数,是实施预维护的完美基础。允许实验室预标定传感器,现场快速更换传感器,尽可能缩短生产中断时间。化工工艺过程和过程监测:高浓度毒性介质,比如H2SpH值快速波动通过ATEX、IECEx、CSA C/US、NEPSI、Japan、INMETRO认证,可以在防爆0区、1区和2区中使用。优势电极专有离子捕捉阱有效防止引线和参比系统的毒性扩散,能够测量强酸和强碱,电极使用寿命长。可选带压参比系统,可靠测量易堵塞介质,比如分散液。允许电极倒装,安装灵活感应式电缆连接和非接触式信号传输避免了潮湿和腐蚀工况对测量的影响,提高了过程完整性。现场快速更换电极,缩短生产停机时间,降低运营成本。Memosens 2.0数字技术支持扩展数据存储,保存标定参数和过程参数,支持趋势识别和预维护。同时也是推进IIoT技术的完美基础。成功案例监测乳液的聚合反应通过反应结束检测和动力学控制实现工艺优化半间歇聚合工艺拉曼分析仪采用Kaiser拉曼技术,用于监测和控制半间歇聚合工艺