邻甲苯胺及其同分异构体的分离The Separation of O-Toluidine and Its isomers摘要:为了实现邻甲苯胺及其同分异构体的完全分离,首先,作者将邻甲苯胺及其同分异构体乙酰化,然后采用气相色谱-质谱联用方法,通过改进色谱条件,使其取得了完全分离。试验表明采用气-质联用方法可以实现邻甲苯胺及其同分异构体的完全分离。关键词:邻甲苯胺;分离;异构体;乙酰化Abstract: In order to achieve the complete separation of o-toluidine and its isomers, firstly, o-toluidine and its isomers were acetylation, and then the authors used gas chromatography-mass spectrometry methods, by improving the chromatographic conditions, so as to achieve their completely separation. The results showed that the gas-chromatography-mass spectrometry method can achieve the completely separation of o-toluidine and its isomers.Keywords: o-toluidine; separation; isomers; acetylation1 前言在禁用偶氮染料检测过程中,邻甲苯胺是经常被检出者之一。邻甲苯胺有两个同分异构体,分别是间甲苯胺和对甲苯胺。其中,邻甲苯胺属于禁用芳香胺,而间甲苯胺和对甲苯胺则不属于禁用芳香胺。三个化合物的沸点非常接近,分别为:邻甲苯胺(200±2℃)、间甲苯胺(203±3℃)、对甲苯胺(201±1℃)。而且三者的质谱图很相似,只是分子极性上略有差别,故造成在用气相色谱-质谱联用方法检测到邻甲苯胺时经常出现假阳性结果。如不采用薄层色谱、液相色谱等其它分析手段共同鉴别,是无法判断是否假阳性结果的。但是要排除假阳性结果,就需要重新寻找条件,而且更换仪器费时费力,且多数实验室不一定同时具备这些设备,这就给我们的日常检测工作带来了很多的麻烦和不便。本文作者结合自身知识和经验,对常见的邻甲苯胺及其异构体分离问题进行了研究。通过查阅相关资料,作者发现邻甲基乙酰苯胺(296℃)、间甲基乙酰苯胺(303℃)和对甲基乙酰苯胺(307℃)三者的沸点相差较大,所以作者首先通过试验将邻甲苯胺及其异构体分别乙酰化,然后通过改进色谱条件,使以上化合物达到了完全分离,提高了检测效率,减少了检测过程中的假阳性检出。 2 试验2.1 仪器与试剂气相色谱-质谱联用仪(GC-MS):Agilent 7890A/5975C,美国Agilent公司毛细管柱:DB-17MS柱(30m×0.25mm×0.25μm)叔丁基甲醚、乙酸酐、无水碳酸钠和无水碳酸钾均为分析纯 旋转蒸发仪 上海亚荣生化仪器厂邻甲苯胺及其同分异构体均为德国Dr.Ehrenstorfer公司。2.2 试剂配制标准品溶液:用叔丁基甲醚为溶剂,分别称取适量邻甲苯胺、间甲苯胺和对甲苯胺标准品配成合适浓度的单标溶液及混合溶液。碳酸钾溶液:0.1mol.L-1水溶液,取13.8g[font
求分离对甲苯磺酸,邻甲苯磺酸,间甲苯磺酸的方法。用的是安捷轮1200,c18柱。谢谢了[em0812]
[align=left][font=宋体][color=#fe2419][color=#000000][1006] [/color]维权声明:本文为[/color][url=http://bbs.instrument.com.cn/user.asp?username=dahua1981][color=#444444][size=2]dahua1981[/size][/color][/url][size=2][color=#fe2419]原创作品,本作者与仪器信息网是该作品合法使用者,该作品暂不对外授权转载。其他任何网站、组织、单位或个人等将该作品在本站以外的任何媒体任何形式出现的,均属侵权违法行为,我们将追究法律责任。[/color][/size][/font][/align][align=center][size=3][font=宋体][b]邻甲苯胺及其同分异构体的分离[/b][/font][/size][b][size=3][font=Times New Roman]The Separation of O-Toluidine and Its isomers[/font][/size][/b][/align][align=left][size=3][font=宋体]摘要:为了实现邻甲苯胺同分异构体的完全分离,作者采用[url=https://insevent.instrument.com.cn/t/Mp]气相色谱[/url][/font][font=Times New Roman]-[/font][font=宋体]质谱联用方法,通过改进色谱条件,使其取得了较好分离。试验表明采用气[/font][font=Times New Roman]-[/font][font=宋体]质联用方法可以实现邻甲苯胺同分异构体的较好分离。[/font][/size][size=3][font=宋体]关键词:邻甲苯胺;分离;异构体[/font][/size][font=Times New Roman][size=3][b]Abstract:[/b] [/size][back=white][size=2]In order to achieve the complete separation of [/size][/back][size=3]o-toluidine[/size][back=white][size=2] and its isomers, the authors used gas chromatography-mass spectrometry methods, by improving the chromatographic conditions, so as to achieve their better separation. The results showed that the gas-chromatography-mass spectrometry method can achieve the better separation of [/size][/back][size=3]o-toluidine[/size][back=white] and its isomers.[/back][/back][/back][/back][/back][/back][/back][/back][/back][/back][/back][/back][/back][/font][size=3][font=Times New Roman][b]Keywords:[/b] o-toluidine separation isomers[/font][/size][size=3][font=Times New Roman][/font][/size][size=3][b][font=Times New Roman]1 [/font][font=宋体]前言[/font][/b][/size][size=3][font=宋体]在禁用偶氮染料检测过程中,邻甲苯胺是经常被检出者之一。邻甲苯胺有两个同分异构体,分别是间甲苯胺和对甲苯胺。其中,邻甲苯胺属于禁用芳香胺,而间甲苯胺和对甲苯胺则不属于禁用芳香胺。三个化合物的沸点非常接近,分别为:邻甲苯胺([/font][font=Times New Roman]200±[/font][font=Times New Roman]2[/font][font=宋体]℃[/font][font=宋体])、间甲苯胺([/font][font=Times New Roman]203±[/font][font=Times New Roman]3[/font][font=宋体]℃[/font][font=宋体])、对甲苯胺([/font][font=Times New Roman]201±[/font][font=Times New Roman]1[/font][font=宋体]℃[/font][font=宋体])。而且三者的质谱图很相似,只是分子极性上略有差别,故造成在用[url=https://insevent.instrument.com.cn/t/Mp]气相色谱[/url][/font][font=Times New Roman]-[/font][font=宋体]质谱联用方法检测到邻甲苯胺时经常出现假阳性结果。[/font][/size][size=3][font=宋体]如不采用薄层色谱、液相色谱等其它分析手段共同鉴别,是无法判断是否假阳性结果的。但是要排除假阳性结果,就需要重新寻找条件,而且更换仪器费时费力,且多数实验室不一定同时具备这些设备,这就给我们的日常检测工作带来了很多的麻烦和不便。本文作者结合自身知识和经验,对常见的邻甲苯胺及其异构体分离问题进行了研究。作者通过改进色谱条件,使以上化合物达到很好的分离,提高了检测效率,减少了检测过程中的假阳性检出。[/font][font=Times New Roman] [/font][/size][size=3][b][font=Times New Roman]2 [/font][font=宋体]试验[/font][/b][/size][size=3][b][font=Times New Roman]2.1 [/font][font=宋体]仪器与试剂[/font][/b][/size][size=3][font=宋体][url=https://insevent.instrument.com.cn/t/Mp]气相色谱[/url][/font][font=Times New Roman]-[/font][font=宋体]质谱联用仪([/font][font=Times New Roman]GC-MS[/font][font=宋体]):[/font][font=Times New Roman]Agilent 7890A/5975C[/font][font=宋体],美国[/font][font=Times New Roman]Agilent[/font][font=宋体]公司[/font][/size][size=3][font=宋体]毛细管柱:[/font][font=Times New Roman]DB-17MS[/font][font=宋体]柱([/font][font=Times New Roman]30m×0.25mm×0.25μm[/font][font=宋体])[/font][/size][size=3][font=宋体]甲醇[/font][font=Times New Roman] [/font][font=宋体]色谱纯[/font][font=Times New Roman] [/font][font=宋体]美国[/font][font=Times New Roman]Fisher[/font][font=宋体]公司[/font][/size][size=3][font=宋体]旋转蒸发仪[/font][font=Times New Roman] [/font][font=宋体]上海亚荣生化仪器厂[/font][/size][size=3][font=宋体]邻甲苯胺及其同分异构体均为德国[/font][font=Times New Roman]Dr.Ehrenstorfer[/font][font=宋体]公司。[/font][/size][size=3][b][font=Times New Roman]2.2 [/font][font=宋体]试剂配制[/font][/b][/size][size=3][font=Times New Roman] [/font][font=宋体]用色谱纯级甲醇为溶剂,分别称取适量邻甲苯胺、间甲苯胺和对甲苯胺标准品配成合适浓度的混合溶液。[/font][/size][size=3][b][font=Times New Roman]2.3 [/font][font=宋体]仪器操作条件[/font][/b][/size][size=3][font=宋体]色谱柱:[/font][font=Times New Roman]DB[/font][font=宋体]一[/font][font=Times New Roman]17MS 30m×0.25mm×0.25μm[/font][font=宋体];温度:进样口[/font][font=Times New Roman]220[/font][font=宋体]℃[/font][font=Times New Roman] [/font][font=宋体];辅助器[/font][font=Times New Roman]280[/font][font=宋体]℃[/font][font=宋体];离子源[/font][font=Times New Roman]230[/font][font=宋体]℃[/font][font=Times New Roman] [/font][font=宋体];四极杆温度:[/font][font=Times New Roman]150[/font][font=宋体]℃[/font][font=宋体];柱温:[/font][font=Times New Roman]40[/font][font=宋体]℃[/font][font=宋体]保持[/font][font=Times New Roman]2[/font][font=宋体]分钟,以[/font][font=Times New Roman]10[/font][font=宋体]℃[/font][font=宋体]/分钟升温至[/font][font=Times New Roman]70[/font][font=宋体]℃[/font][font=Times New Roman] [/font][font=宋体],保持[/font][font=Times New Roman]20[/font][font=宋体]分钟,再以[/font][font=Times New Roman]30[/font][font=宋体]℃[/font][font=宋体]/分钟升至[/font][font=Times New Roman]280[/font][font=宋体]℃[/font][font=宋体],保持[/font][font=Times New Roman]0[/font][font=宋体]分钟;载气:[/font][font=Times New Roman]He[/font][font=宋体];流速:[/font][font=Times New Roman]1.0ml/[/font][font=宋体]分钟;离子化方式:[/font][font=Times New Roman]EI[/font][font=宋体];质量扫描范围:[/font][font=Times New Roman]35amu-350amu[/font][font=宋体];进样方式:不分流进样;进样[/font][font=Times New Roman]0.2μ L[/font][font=宋体]。[/font][/size][size=3][b][font=Times New Roman]3 [/font][font=宋体]结果与讨论[/font][/b][/size][size=3][b][font=Times New Roman]3.1 [/font][font=宋体]试验结果[/font][/b][/size][size=3][b][font=宋体]([/font][font=Times New Roman]1[/font][font=宋体])邻[/font][font=Times New Roman]([/font][font=宋体]间、对[/font][font=Times New Roman])[/font][font=宋体]甲苯胺总离子流图[/font][/b][/size][/align][align=center][img]http://ng1.17img.cn/bbsfiles/images/2010/10/201010131355_251259_1604317_3.jpg[/img][/align][align=center][size=3][/size][/align][align=center][size=3][font=宋体]图[/font][font=Times New Roman]1 [/font][font=宋体]邻[/font][font=Times New Roman]([/font][font=宋体]间、对[/font][font=Times New Roman])[/font][font=宋体]甲苯胺总离子流图[/font][/size][/align][size=3][font=宋体]由图[/font][font=Times New Roman]1[/font][font=宋体]可以看出,邻甲基苯胺及其异构体在本实验条件下,可以得到较好的分离。保留时间分别为:邻甲基苯胺[/font][font=Times New Roman](27.111[/font][font=宋体]分钟[/font][font=Times New Roman])[/font][font=宋体];间甲基苯胺和对甲基苯胺[/font][font=Times New Roman](27.302[/font][font=宋体]分钟[/font][font=Times New Roman])[/font][font=宋体]。间甲基苯胺和对甲基苯胺保留时间很接近而无法有效分离,但是两者都是非禁用芳香胺,该实验条件是可以满足检测要求的。[/font][/size][size=3][b][font=宋体]([/font][font=Times New Roman]2[/font][font=宋体])[/font][font=Times New Roman] [/font][font=宋体]邻甲苯胺峰纯度[/font][/b][/size][align=center][img]http://ng1.17img.cn/bbsfiles/images/2010/10/201010131357_251261_1604317_3.jpg[/img][/align][align=center][size=3][/size][/align][align=center][size=3][font=宋体]图[/font][font=Times New Roman]2 [/font][font=宋体]邻甲基苯胺峰纯度及其标准质谱图[/font][/size][/align][size=3][font=宋体]由图[/font][font=Times New Roman]2[/font][font=宋体]可知,在该实验条件下,邻甲苯胺的峰对称性很好,且该峰处只有[/font][font=Times New Roman]106[/font][font=宋体]、[/font][font=Times New Roman]107[/font][font=宋体]、[/font][font=Times New Roman]77[/font][font=宋体]和[/font][font=Times New Roman]79[/font][font=宋体]四个离子,与邻甲苯胺的标准质谱图一致。其中,离子[/font][font=Times New Roman]107[/font][font=宋体]为邻甲苯胺的分子离子,[/font][font=Times New Roman]106[/font][font=宋体]为邻甲苯胺分子的同位素离子;[/font][font=Times New Roman]77[/font][font=宋体]和[/font][font=Times New Roman]79[/font][font=宋体]则来自于邻甲苯胺失去甲基和氨基后的苯环离子。这说明在该实验条件下,邻甲苯胺峰没有其它干扰离子。[/font][/size][size=3][b][font=宋体]([/font][font=Times New Roman]3[/font][font=宋体])[/font][font=宋体]间甲苯胺和对甲苯胺峰纯度[/font][/b][/size][align=center][img]http://ng1.17img.cn/bbsfiles/images/2010/10/201010131358_251262_1604317_3.jpg[/img][/align][align=center][size=3][/size][/align][align=center][size=3][font=宋体]图[/font][font=Times New Roman]3 [/font][font=宋体]间甲基苯胺和对甲基苯胺峰纯度及其标准质谱图[/font][/size][/align][size=3][font=宋体]由图[/font][font=Times New Roman]3[/font][font=宋体]可以看出,[/font][font=宋体]在该试验条件下,[/font][font=宋体]间甲基苯胺和对甲基苯胺虽没完全分离,但它们的峰对称性都很好,该峰处的四个离子与间甲苯胺和对甲苯胺标准质谱图也一致。[/font][/size][size=3][font=宋体]由图[/font][font=Times New Roman]2[/font][font=宋体]和图[/font][font=Times New Roman]3[/font][font=宋体]可以得出,该方法用来鉴别邻甲基苯胺同分异构体是可行的。[/font][/size][size=3][b][font=Times New Roman]3.2[/font][font=宋体]讨论[/font][/b][/size][size=3][font=宋体]在对染料产品中[/font][font=Times New Roman]23[/font][font=宋体]种有害芳香胺含量的测定过程中,由于异构体的存在,并且多数异构体的质谱图很相似,如果保留时间再相同,往往会形成假阳性结果的产生。当前针对有害芳香胺的[url=https://insevent.instrument.com.cn/t/Mp]气相色谱[/url][/font][font=Times New Roman]/[/font][font=宋体]质谱检测方法,大多采用非极性或极性较弱的色谱柱[/font][sup][font=Times New Roman][1-4][/font][/sup][font=宋体],如[/font][font=Times New Roman]HP-5MS[/font][font=宋体],[/font][font=Times New Roman]DB-5MS[/font][font=宋体],[/font][font=Times New Roman]DB-35MS[/font][font=宋体],这些色谱柱普遍存在的缺点是对常见的芳香胺异构体不能很好的分离。本方法通过使用中等极性色谱柱[/font][font=Times New Roman]DB-17MS([/font][font=宋体]固定相等同于[/font][font=Times New Roman]50[/font][font=宋体]%苯甲基聚硅氧烷[/font][font=Times New Roman])[/font][font=宋体],同时使用三阶程序升温,比较好的解决了这个问题。[/font][/size][size=3][font=宋体]在色谱分析中,柱温是一个重要的操作变数,直接影响分离效能和分析速度。柱温对组分分离的影响较大,提高柱温使各组分的挥发靠拢,不利于分离,所以,从分离的角度考虑,宜采用较低的柱温。但柱温太低,被测组分在两相中的扩散速率大为减小,分配不能迅速达到平衡,峰形变宽,柱效下降,并延长了分析时间。选择的原则是:在使最难分离的组分能尽可能好的分离的前提下,尽可能采取较低的柱温,但以保留时间适宜,峰形不拖尾为度。具体操作条件的选择应根据不同的实际情况而定。[/font][/size][size=3][font=宋体]目前,用于极性相近化和物的分析通常采用程序升温,即柱温按预定的加热速度,随时间作线性或非线性的增加。升温的速度一般常是呈线性的,即单位时间内温度上升的速度是恒定的,例如每分钟[/font][font=Times New Roman]2[/font][font=宋体]℃[/font][font=宋体]、[/font][font=Times New Roman]4[/font][font=宋体]℃[/font][font=宋体]、[/font][font=Times New Roman]6[/font][font=宋体]℃[/font][font=宋体]等等。[/font][font=宋体]在较低初始温度,沸点较低的组分,即最早流出的峰可以得到良好的分离。随柱温增加,较高沸点的组分也能较快的流出,并和低沸点组分一样也能得到分离良好的尖峰。[/font][font=Arial][/font][/size][size=3][font=宋体]通过上面的数据可以看出,该方法实现了邻甲基苯胺与间(对)甲苯胺的基线分离,虽然无法实现间甲苯胺和对甲苯胺的完全分离,但是对于邻甲苯胺假阳性结果的排除来说已经足够了。作者通过大量的试验证明,该方法快速、精确、重现性和稳定性好,具有很高的可行性和可靠性。[/font][/size][size=3][b][font=Times New Roman]4 [/font][font=宋体]结论[/font][/b][/size][size=3][font=Times New Roman] [/font][font=宋体]由前文分析可以得出如下结论:[/font][/size][size=3][font=Times New Roman]a) [/font][font=宋体]该方法实现了邻甲基苯胺异构体的较好分离,因此可以不必再用其它手段或方法做异构体的确认,也在一定程度上提高了检测效率,节约了检测成本。[/font][/size][size=3][font=Times New Roman]b)[/font][font=宋体]该方法快速、精确、重现性和稳定性好,具有很高的可行性和可靠性。[/font][/size][size=3][font=宋体]该方法无法实现间甲基苯胺和对甲基苯胺的分离,但是,因为二者皆为非禁用芳香胺,所以该方法仍然具有很好的推广和应用价值。[/font][/size][size=3][font=宋体]参考文献[/font][/size][size=3][font=Times New Roman][1] GB19601-2004,[/font][font=宋体]《染料产品中[/font][font=Times New Roman]23[/font][font=宋体]中有害芳香胺的限量及测定》[/font][font=Times New Roman][s].[/s][/font][/size][size=3][font=Times New Roman][2] [/font][font=宋体]杨继生,徐逸云,蒋华[/font][font=Times New Roman].[/font][font=宋体]对纺织品禁用偶氮染料检测方法的探讨[/font][font=Times New Roman][J].[/font][font=宋体]印染[/font][font=Times New Roman].2005,06:37-39.[/font][/size][size=3][font=Times New Roman][3] [/font][font=宋体]康云[/font][font=Times New Roman]. [/font][font=宋体]禁用偶氮染料检测中的若干问题[/font][font=Times New Roman][J].[/font][font=宋体]中国纤检[/font][font=Times New Roman].2005,8:24-25.[/font][/size][size=3][font=Times New Roman][4] [/font][font=宋体]胡小钟,余建新等[/font][font=Times New Roman].[/font][font=宋体]禁用偶氮染料检测中假阳性结果的鉴别方法[/font][font=Times New Roman][J].[/font][font=宋体]分析化学研究报告[/font][font=Times New Roman].2000[/font][font=宋体],[/font][font=Times New Roman]28(4):411-416.[/font][/size]