局部和透皮药物试验配件
上海析信为荷兰Prosense公司在中国地区的总代理,可以提供符合各种法规、匹配各品牌厂家的溶出仪的全系列规格耗材配件。欢迎来电垂询!本产品:溶出度仪相关局部和透皮药物试验配件,我们可提供Agilent, Distek, Erweka, Hanson, Pharmatest, Sotax等品牌的各种规格型号,详见如下表。Paddle over DiskPart No.DescriptoinOEM RefPSAPPFIVE-HRTransdermal patch holder USP565-190-092PSAPPFIVE-HRCLIPPlastic Clip for PSAPPFIVE-HR (each)65-190-205PSAPPFIVE-HRSCR17 Mesh PTFE Screen for PSAPPFIVE-HR65-190-190PSAPPFIVE-V35-040Transdermal Patch Holder, 1.38” (35mm) Opening (40 Mesh Screen)12-4200PSAPPFIVE-V56Transdermal Patch Holder, 2.20” (56mm) Opening (120 Mesh Screen)12-4230PSAPPFIVE-V80Transdermal Patch Holder, 3.15” (80mm) Opening (16 x 16 Mesh Screen)–PSTD400017Transdermal Patch Holder (35mm) Opening (125 Mesh Screen)GenericPSAPP5S16-3516 Mesh 316 Stainless Steel Screen for PSAPPFIVE-V35 (pack of 25)–PSAPP5S20-3520 Mesh 316 Stainless Steel Screen for PSAPPFIVE-V35 (pack of 25)–PSAPP5S30-3530 Mesh 316 Stainless Steel Screen for PSAPPFIVE-V35 (pack of 25)–PSAPP5S40-3540 Mesh 316 Stainless Steel Screen for PSAPPFIVE-V35 (pack of 25)12-4210PSAPP5S120-56120 Mesh 316 Stainless Steel Screen for PSAPPIVE-V56 ( pack of 25)12-4231PSAPP5S125-35125 Mesh 316 Stainless Steel Screen for PSTD40017 ( pack of 25)–PSCUP03002Cuprophan 500x500mm, pk/10GenericPTFE Suspension CupsFor suspensions, the PTFE suspension cup is a weighted holder with a hemisphericbottom designed to sit at the bottom of a standard 1L vessel to control the exposedsurface area. The suspension is weighed in the center cup prior to analysis in orderto correlate the release rate.Part No.DescriptoinOEM RefPSSUSCUP-WHWeighted holder, 5.72 cm OD, 0.52 cm ID12-4050PSSUSCUP-178Insert cup, 17.5x8.2 mm, use with p/n 12-4055PSSUSCUP-208Insert cup, 20x8是.2 mm, use with p/n 12-4060Polysulfone Membranes for Transdermal TestingPart No.DescriptoinOEM RefPSMDC-PS25-045-0100Membrane filter, 0.45µ m, ø 25mm, Hydrophobic Polysulfone, pk/100–PSMDC-PS30-045-0100Membrane filter, 0.45µ m, ø 30mm, Hydrophobic Polysulfone, pk/100–PSMDC-PS47-045-0100Membrane filter, 0.45µ m, ø 55mm, Hydrophobic Polysulfone, pk/100–Enhancer CellAn alternative to the Vertical Diffusion or Franz Cell for testing semisolids, the Enhancer or Immersion Cell is used with a special 200ml flat bottomed vessel with mini paddle. The PTFE Immersion Cell is designed to accommodate a 25 mm diameter membrane. It comprises four main parts:&bull A retaining ring which secures the membrane to the cell body and ensures full contact with the sample.&bull A washer which holds the membrane in contact with the sample and provides a leak-proof seal between the membrane, retaining ring and cell body..&bull the membrane or skin and&bull adjustment plate - allows control of the volume of the reservoir within the cell body. This threaded part can be placed at the appropriate height for each test and can be completely removed for easy cleaning. A Viton O-ring prevents leakage.&bull the cell body which contains the compartment in which the sample (semisolid, solution, suspension, or emulsion )to be tested is placed.&bull the cell is provided with an alignment tool and an adjustment tool that allows the user to vary the volume of the reservoir within the cell. Part No.DescriptoinOEM RefPSENHANC-040Enhancer Cell, 4 cm2 surface area membrane12-4000PSENHANC-020Enhancer Cell, 2 cm2 surface area membrane12-4001PSENHANC-005Enhancer Cell, 0.5 cm2 surface area membrane12-4002PSENHANC-TOLAdjustment tool, for all Enhancer Cell sizes12-4015PSENHANC-A40Alignment tool, for 4 cm2 Enhancer Cell12-4010PSENHANC-A20Alignment tool, for 2 cm2 Enhancer Cell12-4011PSENHANC-A05Alignment tool, for 0,5 cm2 Enhancer Cell12-4012Compatible for 7000, 7010, 7020 and 7025 SystemsPart No.DescriptoinOEM RefPSGLA200F-VK200ml Clear glass vessel, flat bottom–PSCOVERV-LL200Low evaporation cover with Cannula Hole–PSSMVASSY-TCSmall Volume Magnet. Adapter Vessel–PSMINEPD-01Spin on/off mini paddle, 316S.S.12-1443 13-3608Compatible for 708-DS SystemsPart No.DescriptoinOEM RefPSGLA200F-TA200ml Clear glass vessel, flat bottom12-5170PSCOVERV-LL200Low evaporation cover with Cannula Hole–PSSMVASSY-TASmall Volume Vessel Conversion Adapter12-6268PSMINEPD-01Spin on/off mini paddle, 316S.S.12-1443 13-3608Compatible for 705-DS, 7000 and 7010 SystemsPart No.DescriptoinOEM RefPSGLA200F-01200ml Clear glass vessel, flat bottom12-5055PSSMVCOV-VKLow evaporation cover with Cannula Hole–PSSMVASSY-VKSmall Volume Vessel Conversion Adapter, incl. cover–PSMINEPD019-01Spin on/off mini paddle, 316S.S.12-1443 13-3608Compatible for 2100, 2500 and Evolution 6300 SystemsPart No.DescriptoinOEM RefPSGLA200F-DK200ml Clear glass vessel, flat bottom3010-0099PSSMVCOV-DKLow evaporation cover with Cannula Hole–PSSMVASSY-DKSmall Volume Vessel Conversion Adapter, incl. cover2800-0602PSMINBLD-DKDetachable mini paddle blade, 316S.S.3200-0185Compatible DT126, DT720, DT820, DT1410 and DT1610 SystemsPart No.DescriptoinOEM RefPSGLA200F-EW200ml Clear glass vessel, flat bottom21612PSSMVASSY-EWSmall Volume Vessel Conversion Adapter–PSCOVERV-LL200Low evaporation cover with Cannula Hole–PSMINEPD-EWLHSpin on/off mini paddle, 316S.S., LH–Research Compatible for SR6, SR8-Plus SystemsPart No.DescriptoinOEM RefPSGLA150F-HR150ml Clear glass vessel, flat bottom72-600-57274-105-152PSCOVERH-LL200Low evaporation cover with Cannula Hole–PSSMVASSY-HRSmall Volume Vessel Conversion Adapter72-800-714PSMINEPD-HRSpin on/off mini paddle, 316S.S.74-105-204Research Compatible for Vision Systems Part No.DescriptoinOEM RefPSGLA150F-HR150ml Clear glass vessel, flat bottom72-600-57274-105-152PSCOVERH-LL200Low evaporation cover with Cannula Hole–PSSMVASSY-HRSmall Volume Vessel Conversion Adapter72-800-714PSMINEPD-HRSpin on/off mini paddle, 316S.S.74-105-204Immersion Cell for OintmentsThe test is the same as standard dissolution testing, with the exception of using a small (mini) paddle and vessel, with the immersion cell inside the vessel. The ointment is sealed in a delivery chamber where it can only move into the solution through a membrane. Part No.DescriptoinOEM RefPSIMMERC-UNImmersion Cell only, 15 mm65-190-043PSIMMERC-UNTImmersion Cell with tools, 15 mm65-190-051PSMSDC-PS25-045-0100Membrane filter, 0.45µ m, ø 25mm, Hydrophobic Polysulfone pk/100–Extraction cell acc. to EP 2.9.4. chapter 3The cell holds the patch flat, with the release surface uppermost and parallel to the bottom of the paddle blade. A distance of 25 ± 2 mm is maintained between the paddle blade and the surface of the patch. The temperature is maintained at 32 ± 0.5 °C. The vessel may be covered during the test to minimise evaporation. Part No.DescriptoinOEM RefPSEXCELL-27Extraction Cell, 27mm, 1,48ml18421PSEXCELL-38Extraction Cell, 38mm, 2,94ml22252PSEXCELL-45Extraction Cell, 45mm, 4,13ml22253PSEXCELL-52Extraction Cell, 52mm, 5,52ml22254 Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-EW01Rotating Cylinder S.S., UniShaft, short version, to screw to Shaft81-000-900022408PSAPPSIX-EW01LRotating Cylinder S.S., UniShaft, long version, to screw to Shaft81-000-901022409PSAPPSIX-EW02Rotating Cylinder S.S., MagniShaft short version, with Shaft for Low-Head useShaft for Low-Head use 84-000-900084-000-9000PSAPPSIX-EW02LRotating Cylinder S.S., MagniShaft long version, with Shaft for Low-Head use84-000-9010Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-01Rotating Cylinder for Transdermal Patches, 316S.S.12-1360PSAPPSIX-01LLong version Rotating Cylinder–Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-HRRotating Cylinder for Transdermal Patches, 316S.S.65-590-011PSAPPSIX-HRLLong version Rotating Cylinder-PSSPNAPP6-HRVSpin ON/OFF USP APP 6 Rotating Cylinder for Transdermal Patches, Vision Compatible, Electropolished 316S.S.74-105-240PSSPNAPP6-HRVLSpin ON/OFF USP APP 6 Rotating Long Cylinder for Transdermal Patches, Vision Compatible, Electropolished 316S.S.-Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-HRRotating Cylinder for Transdermal Patches, 316S.S.65-590-011PSAPPSIX-HRLLong version Rotating Cylinder-PSSPNAPP6-HRVSpin ON/OFF USP APP 6 Rotating Cylinder for Transdermal Patches, Vision Compatible, Electropolished 316S.S.74-105-240PSSPNAPP6-HRVLSpin ON/OFF USP APP 6 Rotating Long Cylinder for Transdermal Patches, Vision Compatible, Electropolished 316S.S.- Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-ELRotating Cylinder for Transdermal Patches, Electropolished 316 Stainless Steel0103A00184PSAPPSIX-ELLLong version Rotating Cylinder0103A00183 Rotating Cylinder/旋转气缸 Part No.DescriptoinOEM RefPSAPPSIX-STRotating Cylinder for Transdermal Patches, Electropolished 316 Stainless Steel7663PSAPPSIX-STLLong version Rotating Cylinder–