推荐厂家
暂无
暂无
近来实验室一台液相连续出现马达过热现象,机龄已经9年了,想想估计内部不少磨损了。虽然经常性氮气吹吹灰,但是导轨那一头还没有很仔细的清理过,今天就拆拆、擦擦、吹吹。直接拆开,才过了没几个月,主板的积灰已经看得出了。[img=拆拆拆,690,920]https://ng1.17img.cn/bbsfiles/images/2021/06/202106041416421701_3716_1627995_3.jpg!w690x920.jpg[/img]各种地方找了一圈,结合是抓臂抬起来的时候卡住,就专门看了抓臂抬起相关的部位,真发现一些固体碎屑。图中导轨边上,黄黄的一些东西,照片里比较模糊。只能吹掉。[img=问题症结?,690,920]https://ng1.17img.cn/bbsfiles/images/2021/06/202106041416420638_335_1627995_3.jpg!w690x920.jpg[/img]其他部位的各种顶端有一些沉积物,擦擦擦。[img=擦擦擦,690,517]https://ng1.17img.cn/bbsfiles/images/2021/06/202106041416418595_9717_1627995_3.jpg!w690x517.jpg[/img]导轨的锈蚀痕迹。[img=锈蚀,690,1226]https://ng1.17img.cn/bbsfiles/images/2021/06/202106041416433060_3476_1627995_3.jpg!w690x1226.jpg[/img]各种搞完,测试了一下,暂时可以苟延残喘。如果下次问题再来,只能大“拆”大合。最后请教各位大神,对于机龄10年的机子是怎么处理的呢,特别是企业实验室?买维保还是单独送修?我这边一台机子今年两块主板换了,都是CAN接口故障。送修也要3W了,可是谁知道买了维保就强行续命不坏了。毕竟我是遇到过维保合同刚结束4天,[url=https://insevent.instrument.com.cn/t/Mp]气相[/url]加热丝接头断了的人。。。
吹扫捕集-气相色谱质谱法同步测定水中挥发性卤代烃、氯代苯和苯系物章 勤 黄酉腊 舒天阁 王曙兴 包杰(宁波市镇海区环境监测站,浙江 宁波 315200) 摘 要:建立了吹扫捕集气相色谱质谱联用法同时测定水中卤代烃、氯代苯和苯系物的方法,对吹扫条件和解析条件进行了优化。结果表明,经分析条件优化后,目标化合物的曲线相关系数在0.995~0.9995之间,方法的检出限在0.03~0.49 ug/L之间,相对标准偏差在1.28%~7.29%之间,方法具有很好的线性和精密度。方法用于地表水、生活污水和化工废水中23种有机物的测定,并进行了加标回收实验,地表水回收率在97.2%~109.9%之间,生活污水回收率在93.2%~113.1%之间,废水回收率在93.1%~106.4%之间,表明方法具很好的准确度,可用于地表水、生活污水和化工废水中23种有机物的测定。关 键 词:吹扫捕集;气相色谱/质谱;挥发性卤代烃;氯代苯;苯系物中图分类号:O657 文献标识码: A 文章编号: 1671-0460(2018)00-0000-00 Synchronous Determination of VolatileHalohydrocarbons, Chlorobenzenes and Benzene Homologs in Water by GasChromatography/Mass Spectrometry Coupled with Purge and Trap ZHANG Qin, HUANG You-la, SHU Tian-ge, WANGShu-xing, BAO Jie(Zhenhai Environmental Protection Monitoring Centre, Ningbo 315200,China) Abstract: A method was established to determine volatilehalohydrocarbons, chlorobenzenes and benzene homologs in water by purge andtrap coupled with gas chromatography/mass spectrometry. The purge and trapcondition were optimized. Results showed that the calibration curve withcorrelation coefficient between 0.995-0.9995, detection limits 0.03~0.49 ug/Land RSD of the method 1.28%~7.29%, the method was applied to the analysis insurface water and domestic sewage and industrial wastewater. Average recoveryof the samples was 97.2%-109.9% in surface water, 93.2%-113.1% in domesticsewage and 93.1%-106.4% in industrial wastewater respectively. The method whichhas good accuracy can be used for synchronous determination of volatilehalohydrocarbons, chlorobenzenes and benzene homologs in surface water,sewage and wastewater.Key words: Purge and trap; Gas chromatography/mass spectrometry; Volatilehalohydrocarbons; Chlorobenzene; Benzene homologs 近年来,工业的快速发展引起大量的工业废水进入到水环境中,尤其是含有大量有机物的工业废水。其中,挥发性卤代烃、氯代苯和苯系物在工业生产中被大量使用,但其具有毒性,且易在生物体中富集,对人们的生存环境和人体健康构成潜在的威胁而引起大量的关注。因此,对水中挥发性卤代烃、氯代苯和苯系物进行快速、准确分析的要求也越来越迫切。挥发性卤代烃、氯代苯和苯系物的检测方法通常采用顶空法和吹扫捕集法,与顶空法相比,吹扫捕集法具有富集效率高、受基体干扰小等优点,是目前水质分析中较为灵敏的样品前处理技术,与气相色谱-质谱法(GC-MS)联用已广泛使用于有机物的测定,能准确地对待测组分进行定性定量分析。本文采用吹扫捕集-气相色谱质谱法对地表水、生活污水和工业废水中卤代烃、氯代苯和苯系物等23 种污染物进行定性和定量分析。该分析方法具有精密度好、成本低、分析效率高等优点,可用于地表水、生活污水和化工废水中23种有机物的测定。1 材料与方法1.1 仪器与试剂仪器:气相色谱-质谱联用仪:Agilent 6890N,Agilent5975质量检测器,美国安捷伦公司;吹扫捕集仪:TEKMAR Atomx, 5ml吹扫管,美国TEKMAR公司;[/color
http://ng1.17img.cn/bbsfiles/images/2013/07/201307141608_451227_2729383_3.jpg氩气净化器是中科普瑞的CZA-4N ,催化温控出现降低的现象,设定温度是250,但温度一直在41 42度左右徘徊(期间没有出现停电,也没停机)。然后就找了个电工过来看了下,他也就把前面的柜门打开 里面吹吹灰拨了拨电线,然后温度就开始回升了。难倒是电线接触不良?还是积灰太多了。