Acclaim PolarAdvantage 061316反相色谱柱

品牌: 戴安
供货周期: 现货
报价: 面议
获取电话
留言咨询
产品介绍

Sulfonamide-Embedded Reversed-Phase Columns for Separating Polar Compounds

Acclaim® PolarAdvantage (PA) columns feature a patented bonding chemistry that incorporates a polar sulfonamide group near the surface of the silica particle. This unique chemistry provides good hydrolytic stability and allows a single column to resolve a wide variety of polar and nonpolar analytes. The Acclaim PA is compatible with 100% aqueous mobile phases and supports LC/MS analysis.

· Low silanol activity for excellent peak shape with basic compounds
· Novel polar-embedded column chemistry
· Compatible with 0–100% organic solvent mobile phases
· High selectivity for hydrophobic aromatic compounds
· Wide range of applications

Conventional C18 phases are not compatible with highly aqueous mobile phases, due to dewetting. The Acclaim PA column by design has a mildly hydrophilic surface, which remains in contact with aqueous-only mobile phases, negating the problems of dewetting common with conventional reversed-phase columns.

Acclaim PA columns are available both in 3 and 5 μm particle sizes and 4.6, 3.0, and 2.1 mm diameters, with an average pore diameter of 120 ?. Acclaim PA is also available in 2.2μm RSLC format (see Acclaim Rapid Separation LC (RSLC) Columns section for more details). Acclaim PA may be used for LC/MS applications.


Applications

The Acclaim PA column can be used in a wide range of applications in pharmaceutical, environmental, food testing, and product-quality testing. These columns also give efficient separations with good peak shapes for compounds of life science (nucleic acid and bases) and pharmaceutical interest (sulfonamides) using highly aqueous mobile phases.


Acclaim PolarAdvantage: Rugged Polar-Embedded Reversed-Phase Columns for the Analysis of Polar and Nonpolar Compounds Specifications
Surface coverage2.7 μmol/m2
End-cappedYes
Metal impurity (Na, Fe, Al)<10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume1.0 mL/g
Average pore diameter120 ?
Surface area300 m2/g
pH range2–8
Temperature<60 °C
Starting materialUltrapure silica
Particle size3 and 5 μ
Particle shapeSpherical
Particle size distribution (40/90)<1.3
Total carbon content17%

Standard particle sizes are 3 and 5 μm. Available in 2.1, 3.0, and 4.6  mm i.d. Lengths are 50, 100, and 150 mm. Capillary formats are available in 75 and 300 μm, 1.0 mm, and custom diameters, and in 50, 150, or 250  mm lengths. Micro precolumn and nano precolumn cartridges are available  in several formats. Guard columns in both 2.0 and 4.3 mm sizes packed  with 5 μm particles are recommended. Columns for fast LC are listed in  the RSLC section.


Analytical Columns
Acclaim PA, 3 μm Analytical (2.1 x 50 mm)063174
Acclaim PA, 3 μm Analytical (2.1 x 100 mm)061316
Acclaim PA, 3 μm Analytical (2.1 x 150 mm)061317
Acclaim 120, PA, 3μm Analytical (2.1 x 250mm)076215
Acclaim PA, 3μm Analytical, (3.0 x 50mm)068972
Acclaim 120, PA, 3μm Analytical (3.0 x 100mm)076214
Acclaim PA, 3 μm Analyitcal (3.0 x 150 mm)063693
Acclaim PA, 3 μm, Analytical, (3.0 x 250 mm)070079
Acclaim PA, 3 μm Analytical (4.6 x 150 mm)061318
Acclaim 120, PA, 3μm Analytical (4.6 x 100mm)076216
Acclaim PA, 5 μm Analytical (4.6 x 50 mm)061319
Acclaim PA, 5 μm Analytical (4.6 x 150 mm)061320
Acclaim PA, 5 μm Analytical (4.6 x 250 mm)061321


Guard Columns
Acclaim PA, 5μm,2mm Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580069691
Acclaim PA, 5μm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580071983
Acclaim PA, 5 μm Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder)069698
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188


Acclaim RSLC PA Analytical Columns
Acclaim RSLC PA, 3 μm Analytical (3.0 x 33 mm)066274
Acclaim PA, 3μm Analytical, (3.0 x 50mm)068972
Acclaim RSLC PA, 3 μm Analytical (3.0 x 75 mm)066275
Acclaim PA, 3 μm Analyitcal (3.0 x 150 mm)063693
Acclaim RSLC PA, 2.2μm, 2.1 x 50 mm072622
Acclaim RSLC PA, 2.2μm, 2.1 x 30 mm072621
Acclaim RSLC PA, 2.2μm, 2.1 x 100 mm072623
Acclaim RSLC PA, 2.2μm, 2.1 x 150 mm072624
Acclaim RSLC PA, 2.2μm Analytical (2.1 x 250mm)074813
Acclaim RSLC PA, 2.2μm, 3 x 30mm072625
Acclaim RSLC PA, 2.2μm, 3 x 100mm072627
Acclaim RSLC PA, 2.2μm, 3 x 50mm072626




Acclaim PolarAdvantage 061316反相色谱柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于Acclaim PolarAdvantage 061316反相色谱柱报价、型号、参数等信息,欢迎来电或留言咨询。除供应Acclaim PolarAdvantage 061316反相色谱柱外,上海希言科学仪器有限公司还可为您提供Corning/康宁431471离心管盖,15ML,100个/包,5包/箱、Corning/康宁8674冻存盒,100孔,PC材质,配套2D冻存管,带码、Corning/康宁3570BC384微孔板,白色,低边框,TC处理,带条码,带盖,平底,灭菌等产品,公司有专业的客户服务团队,是您值得信赖的合作伙伴。
工商信息

企业名称

上海希言科学仪器有限公司

企业信息已认证

企业类型

有限责任公司(自然人投资或控股)

信用代码

91310117301434080L

成立日期

2014-05-26

注册资本

人民币100.0000万元整

经营范围

一般项目:技术服务、技术开发、技术咨询、技术交流、技术转让、技术推广;仪器仪表销售;实验分析仪器销售;光学仪器销售;货物进出口;技术进出口。(除依法须经批准的项目外,凭营业执照依法自主开展经营活动)

联系我们
推荐产品
供应产品

上海希言科学仪器有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
立即咨询
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系我们:

企业名称: 上海希言科学仪器有限公司

企业地址: 上海市松江区九亭镇涞寅路1025号立同国际商务大厦3067室 联系人: 万经理 邮编: 201615 联系电话: 400-860-5168转3944

仪器信息网APP

展位手机站