您好,欢迎访问仪器信息网
注册
上海希言科学仪器有限公司

关注

已关注

银牌8年 银牌

已认证

粉丝量 0

400-860-5168转3944

仪器信息网认证电话,请放心拨打

当前位置: 仪器信息网 > 希言仪器 > 糖专用柱 > GlycanPac AXH-1糖分析柱 082472

GlycanPac AXH-1糖分析柱 082472

品牌: 戴安
供货周期: 现货
报价: 面议
获取电话
留言咨询
产品介绍

GlycanPac AXH-1 Glycan Analysis Column

GlycanPac AXH-1 Columns for the High-Resolution Separation and Analysis of Glycans

The Thermo Scientific GlycanPac AXH-1 column is a high-performance, silica-based HPLC column for simultaneous separation of glycans by charge, size, and polarity. It is designed for high-resolution and high-throughput analysis with unique selectivity for biologically important glycans, either labeled or native, by LC-fluorescence and LC-mass spectrometry (MS) methods.

The GlycanPac AXH-1 column can be used for qualitative, quantitative, and structural characterization of uncharged and charged glycans present in biological molecules (e.g., proteins).

Features:

  • Unique glycan selectivity based on charge, size, and polarity

  • Excellent resolution for both native and labeled glycans

  • Useful for both high-resolution glycan profile characterization and easy quantification of glycans based on charge

  • Compatible with fluorescence and MS detection methods

  • High chromatographic efficiency and excellent column stability

The GlycanPac AXH-1 column, based on innovative mixed-mode surface chemistry, combines both weak anion-exchange (WAX) and hydrophilic interaction liquid chromatography (HILIC) retention mechanisms for optimal selectivity and resolution power. The WAX functionality provides retention and selectivity for negatively charged glycans, while the HILIC mode facilitates the separation of glycans of the same charge according to their polarity and size. As a result, the GlycanPac AXH-1 column provides unparalleled capabilities for glycan separations. Additionally, this column offers charge-based separations for various glycans without discrimination of size and polarity, making it a suitable tool for accurate quantification of glycans which cannot be achieved with other HPLC columns. The GlycanPac AXH-1 column is designed and tested for LC-fluorescence detection and LC-MS applications using volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile.

GlycanPac AXH-1 columns are based on high-purity and spherical silica substrates in both 1.9 and 3 μm sizes for UHPLC and standard HPLC applications, respectively. GlycanPac AXH-1 columns are available in various dimensions for applications with different resolutions, throughput, and instrument requirements.

GlycanPac AXH-1 Column Specifications
Column Dimensions

1.9 μm: 2.1 × 250mm, 2.1 × 150mm, 2.1 ×100mm

3 μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mm

Bead SizeSpherical 1.9 μm, 3 μm particles
SubstrateHigh-purity, Porous, Spherical Silica


Functional GroupWAX and HILIC Mixed-Mode
Recommended Flow Rate Range:

1.9 μm: 0.1 to 0.4 mL/min. for:  all 2.1 mm columns

3 μm: 0.6 to 1.2 ml/min  for 4.6  × 150 mm 

          0.3 to 0.6 ml/min  for 3.0  × 150 mm  

          0.1 to 0.5 ml/min. for 2.1 × 150 mm

Pressure Limit

1.9 μm: 7,000 psi for 2.1 × 100mm,

             10,000 psi for 2.1 ×150mm

             15,000 psi for 2.1 × 250mm

3 μm: 6,000 psi for all 3 μm columns

Temperature Range:Ambient to 60  oC
pH Range2.0 - 8.0
Analytical Columns
GlycanPac AXH-1, 3 μm, Analytical (4.6x150mm)082468
GlycanPac AXH-1, 3 μm, Analytical (3.0x150mm)082469
GlycanPac AXH-1, 3 μm, Analytical (2.1x150mm)082470
GlycanPac AXH-1, 1.9 μm, Analytical (2.1x250mm)082521
GlycanPac AXH-1, 1.9 μm, Analytical (2.1x150mm)082472
GlycanPac AXH-1, 1.9 μm, Analytical (2.1x100mm)082473
GlycanPac AXH-1, 1.9 μm, Analytical (1.0 × 150 mm, with nanoViper)164863
Guard Columns
GlycanPac AXH-1, 3 μm, Guard (4.6x10 mm) 2ea (Use Holder V-2)082474
GlycanPac AXH-1, 3 μm, Guard (3.0x10 mm) 2ea (Use Holder V-2)082475
GlycanPac AXH-1, 3 μm, Guard (2.1x10 mm) 2ea (Use Holder V-2)082476
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188



GlycanPac AXH-1糖分析柱 082472信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于GlycanPac AXH-1糖分析柱 082472报价、型号、参数等信息,欢迎来电或留言咨询。除供应GlycanPac AXH-1糖分析柱 082472外,上海希言科学仪器有限公司还可为您提供Corning/康宁368896孔板 半量全白板 平底 TC表面 PS(聚苯乙烯)材质、Corning/康宁3570BC384微孔板,白色,低边框,TC处理,带条码,带盖,平底,灭菌、Corning/康宁360596孔板 白色 圆底 NBS表面 未灭菌等产品,公司有专业的客户服务团队,是您值得信赖的合作伙伴。
工商信息

企业名称

上海希言科学仪器有限公司

企业信息已认证

企业类型

有限责任公司(自然人投资或控股)

信用代码

91310117301434080L

成立日期

2014-05-26

注册资本

人民币100.0000万元整

经营范围

一般项目:技术服务、技术开发、技术咨询、技术交流、技术转让、技术推广;仪器仪表销售;实验分析仪器销售;光学仪器销售;货物进出口;技术进出口。(除依法须经批准的项目外,凭营业执照依法自主开展经营活动)

联系我们
推荐产品
供应产品

上海希言科学仪器有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
立即咨询
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系我们:

企业名称: 上海希言科学仪器有限公司

企业地址: 上海市松江区九亭镇涞寅路1025号立同国际商务大厦3067室 联系人: 万经理 邮编: 201615 联系电话: 400-860-5168转3944

仪器信息网APP

展位手机站