• Baseline separation ensures accurate determination of 15 commonly analyzed aldehydes and ketones in air samples.
• Raptor™ LC columns give you results in minutes—not hours—for increased sample throughput.
• Restek® certified reference materials are specially formulated for ambient air and automotive emissions testing.
Accurate analysis of aldehydes and ketones in air samples is an important part of monitoring programs that are used to control air pollution and to protect
human health around the world. These airborne carbonyls from industrial and vehicle emissions are precursors to ozone in smog and are associated with
respiratory and pulmonary problems. In addition, specific carbonyls—formaldehyde and acetaldehyde—have been identified as known or suspected
carcinogens. Prior to analysis, aldehydes and ketones are converted to hydrazone derivatives when they are captured on a sampling tube composed of
silica gel coated with 2,4-dinitrophenylhydrazine (DNPH). Then, the aldehyde/ketone DNPH derivatives are eluted from the sampling tube with solvent and
analyzed by HPLC-UV. Typically, carbonyl LC methods require long analysis times (often over an hour), but many still fail to provide adequate resolution for
some aldehyde/ketone DNPH derivatives.
To help labs improve analytical speed and accuracy in the analysis of aldehydes and ketones in air samples, Restek has developed LC columns, instrument
conditions, and certified reference materials that reliably provide baseline separation of commonly analyzed aldehyde/ketone DNPH derivatives in just minutes. For example, airborne carbonyls LC method U.S. EPA Method TO-11A uses a conventional C18 column and requires an analysis time of over one hour,
yet acrolein and acetone partially coelute and the o-, m-, and p- tolualdehyde isomers cannot be fully separated. In contrast, using a Raptor™ C18 column
under the conditions shown below, all 15 carbonyls—including the tolualdehyde isomer cluster—are separated to baseline in a fast 14-minute analysis.
Similarly, airborne carbonyl LC method CARB 1004 produces extremely long analysis times; in fact, this method requires two separate chromatographic
analyses in order to quantify all compounds. The first is a 37-minute analysis using two columns connected in series. Even with two columns and a long
analysis time, methyl ethyl ketone and butyraldehyde coelute in this analysis. To report these two compounds, another 30-minute chromatographic analysis with a different column is needed. However, this second analysis cannot be used to report all compounds due to the coelution of formaldehyde with a
non-carbonyl compound. This same list of CARB 1004 aldehyde/ketone DNPH derivatives can be fully resolved by the second Restek® method shown below
using a Raptor™ ARC-18 column in a fast 8.5-minute analysis—an 8-fold reduction in analysis time with a single column.
Both of these methods from Restek are compatible with conventional 400 bar HPLC systems and benefit from the larger, low-clog frit used in Raptor™
column hardware. Using either Raptor™ LC column—along with Restek’s airborne carbonyl reference standards—assures fast, accurate analysis of
aldehydes and ketones in air and offers an opportunity for improved sample throughput compared to typical columns and methods.
下载本篇解决方案:
更多
YSI防玷污的10个技巧
YSI 防玷污的10点技巧 随着电子技术的进步、电源管理的改进和电池寿命的延长,生物玷污成为目前决定监测仪器投放周期长度的决定因素,特别是应用于长期、连续监测。应用一些防玷污技术可以延长仪器的维护间隔,能够减少野外的仪器维护的次数,并提高水质监测数据精度。 防玷污技巧的详细内容请参考文章《YSI 防玷污的10点技巧》
环保
2014/03/04
NanoBrook产品应用-12-ZetaPALS
文献名: Structural, morphological and optical properties of Bi NPs obtained by laser ablation and their selective detection of L-cysteine 作者: Ramon Gabriel Teixeira Rosaa, Celso de Araujo Duartea , Wido Herwig Schreinera, Ney Pereira Mattoso Filhoa, Arandi Ginane Bezerra Jr.b, Andersson Barisonc, Fernanda Maria Marins Ocamposc a Departamento de Física, Universidade Federal do Paraná Centro Politécnico, CP 19044, 81531-990 Curitiba (PR), Brazil b Departamento Acadêmico de Física, Universidade Tecnológica Federal do Paraná, 80230-901 Curitiba (PR), Brazil c Departamento de Química, Universidade Federal do Paraná Centro Politécnico, CP 19081, 81531-990 Curitiba (PR), Brazil 摘要:In the present work we show the results of the investigation of the properties of bismuth nanoparticles (NPs) obtained by the laser ablation in water. The samples were characterized by various techniques: UV/vis spectroscopy, dynamic light scattering, transmission electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, nuclear magnetic resonance and zeta potential. The NPs were metallic and surface oxidated, exhibiting absorption peak at 257 nm due to the surface plasmon resonance. The interaction between the NPs and various amino acids was studied and revealed a selective sensibility to cysteine on a range of concentration from 80 to 720 μM, which we attribute to a dimerization of cysteine to cystine probably complexed to the nanoparticle surface by electrostatic interactions, leading to the modification of the NP absorption spectrum. 关键词:Bismuth; Nanoparticles; Laser ablation; Cysteine
2015/04/16
安捷伦 Seahorse XF 分析试剂盒与试剂
安捷伦提供多种独特的高质量 Seahorse XF 分析试剂盒、试剂和培养基,用于研究细胞能量代谢功能并实时评估线粒体和糖酵解功能。以简化实验程序和提高研究效率为设计宗旨,使用这些试剂盒能让您简捷地获得高质量恒定的数据。结合安捷伦出色的技术服务,这些试剂盒将极大地提高您的 XF 实验效率和体验。
医疗/卫生
2019/07/18
连华科技 医疗污水检测方案
医疗污水包含了多种细菌、重金属、有机溶剂及酸碱溶液等生化有毒有害物质。如上述物质直接排放,将会对自然生态及人类生活环境造成危害。我国对医疗污水有清晰的排放标准。连华科技对于《医疗机构水污染物排放标准GB18466-2005》中所涉及的参数,多款便携及实验室仪器及耗材可满足检测需求
环保
2020/02/14