Capillary Split/Splitless Injector Liners
DescriptionID mmOD mmLength mmPkgPart no.
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – General purpose use, ideal for chlorinated pesticides analyses2486.25N6502001
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken46.292.15N6121020
Split Glass Liner (with wool) – Universal liner for general purpose analyses4692.15N6502009
Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range4692.15N6502010
Clarus Cup Split Glass Liner – Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean4692.15N6502011
Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections4692.15N6502012
Uniliner Deactivated Glass Liner (with wool) – Universal liner or general purpose analyses46.292.15N6121022
Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with headspace and purge/trap16.292.15N6502006
Quartz Liner for Splitless Operation (ships with instrument) –Standard injector liner26.292.11N6121002
Glass Liner for Splitless Operation – Universal liner for general purpose analyses26.292.11N6101372
Deactivated Glass Liner for Splitless Operation (with wool) – Good for analyses of trace samples26.292.15N6121021
Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken26.292.15N6502004
Quartz Liner for Split Operation – Good for large volume injection samples46.292.11N6121001
Glass Liner for Split Operation – Universal liner for general purpose analyses46.292.11N6101052
Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems46.292.15N6502003
Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean46.292.15N6502005
Zero Dilution Glass Outer Liner – Ideal for trace HS work. Use in conjunction with N101144626.3901N1011445
Zero Dilution Glass Inner Liner – Ideal for trace HS work. Use in conjunction with N101144526.3901N1011446
Programmed Temperature Split/Splitless (PSS) Injector Liners
Quartz Liner for Splitless operation (ships with instrument) – Excellent liner for low volume analyses1486.21N6121006
NEW! Siltek Deactivated Glass PSS Liner – Used for low volume trace sample analyses1486.25N6502000
Quartz Liner for Split operation (ships with instrument) – Approved PerkinElmer standard injector liner2486.21N6121004
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) – Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken2486.25N6502001
NEW! Siltek Deactivated Glass Liner for Split operation – Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range2486.25N6502002
Zero Dilution Outer Liner –Use in conjunction with N10114462.84831N1011447
Zero Dilution Inner Liner –Use in conjunction with N1011447 2731N1011446
On-column Glass Liner2.4486.21N6101539
Liner/Hour Glass for POC Injector2.4419.051N6101703
Quartz Split Liner with Silanized Glass Wool2486.21N6121008
Quartz Split Liner with Silanized Glass Wool2486.25N6121009
Packed Column Injector Liners
Drilled Uniliner (hole on top) – Excellent liner for high sample recovery and linearity, recommended for aqueous injections.46.292.15N6121022
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. Good for PPC equipped GCs46.292.15N6502013
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,active samples, high recovery and linearity46.292.15N6502014
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, active samples, high recovery and linearity46.292.15N6502015
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue46.292.15N6502016
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction46.292.15N6502017
Wide-Bore Column Glass Liner6492.11N6101375
Wide-Bore Column On/Off Quartz Liner6492.11N6121003
Colored Injector Liners
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility2486.25N9306232
Capillary splitless deactivated glass liners with deactivated wool.46.292.15N9306233
Capillary splitless deactivated glass liners with deactivated wool.46.292.11N9306234
Capillary splitless deactivated glass liners with deactivated wool.46.292.15N9306235
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample.46.292.15N9306236
PSS Splitless deactivated glass liners with deactivated wool 5/pk.1.25486.25N9306237

工商信息

企业名称

北京博德恒悦科贸有限公司

企业信息已认证

企业类型

信用代码

110108011785230

成立日期

2009-03-26

注册资本

50

经营范围

技术推广、技术开发、技术转让、技术服务、技术咨询;销售自行开发后的产品、润滑油、金属材料、建筑材料、五金交电、化工产品(不含危险化学品及一类易制毒化学品)、机械设备、电子产品、通讯设备、计算机、软件及辅助设备、医疗器械I类、日用品、汽车零配件;仪器仪表维修;技术进出口、代理进出口、货物进出口。(企业依法自主选择经营项目,开展经营活动;依法须经批准的项目,经相关部门批准后依批准的内容开展经营活动;不得从事本市产业政策禁止和限制类项目的经营活动。)

联系我们
Glass Inlet Liners N1011447,N1011446,N6101539,N6101703,N6121008,N6121009由北京博德恒悦科贸有限公司为您提供,如您想了解更多关于Glass Inlet Liners N1011447,N1011446,N6101539,N6101703,N6121008,N6121009价格、规格、特点、分类选择等信息,欢迎咨询厂家。除供应Glass Inlet Liners N1011447,N1011446,N6101539,N6101703,N6121008,N6121009外,还可为您提供InertSep 2OH 、正相色谱柱 Inertsil 系列Inertsil 5020-06036/5020-19232/5020-19182/5020-19482 、ASSY,COL,SPARES,21.2MM,IT等耗材,公司有专业的客户服务团队,是您值得信赖的合作伙伴,北京博德恒悦科贸客服电话400-860-5168转1683。
推荐产品
供应产品

北京博德恒悦科贸有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 北京博德恒悦科贸有限公司

公司地址: 北京市海淀区安宁庄路26号楼7层713 联系人: 张小姐 邮编: 100085 联系电话: 400-860-5168转1683

仪器信息网APP

展位手机站