您好,欢迎访问仪器信息网
注册
北京博德恒悦科贸有限公司

关注

已关注

银牌16年 银牌

已认证

粉丝量 0

400-860-5168转1683

仪器信息网认证电话,请放心拨打

当前位置: 北京博德恒悦科贸 > 其他色谱配件 > Glass Inlet Liners N6502004,N6121001,N6101052,N6502003,N6502005,N1011445,N1011446

Glass Inlet Liners N6502004,N6121001,N6101052,N6502003,N6502005,N1011445,N1011446

品牌: 珀金埃尔默
供货周期: 现货
报价: 面议
获取电话
留言咨询
产品介绍

 

?

产品名称:Glass Inlet Liners
仪器厂商:PerkinElmer/美国 珀金埃尔默
价格:面议
库存:是

Capillary Split/Splitless Injector Liners
Description ID mm OD mm Length mm Pkg Part no.
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – General purpose use, ideal for chlorinated pesticides analyses 2 4 86.2 5 N6502001
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken 4 6.2 92.1 5 N6121020
Split Glass Liner (with wool) – Universal liner for general purpose analyses 4 6 92.1 5 N6502009
Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 4 6 92.1 5 N6502010
Clarus Cup Split Glass Liner – Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean 4 6 92.1 5 N6502011
Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections 4 6 92.1 5 N6502012
Uniliner Deactivated Glass Liner (with wool) – Universal liner or general purpose analyses 4 6.2 92.1 5 N6121022
Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with headspace and purge/trap 1 6.2 92.1 5 N6502006
Quartz Liner for Splitless Operation (ships with instrument) –Standard injector liner 2 6.2 92.1 1 N6121002
Glass Liner for Splitless Operation – Universal liner for general purpose analyses 2 6.2 92.1 1 N6101372
Deactivated Glass Liner for Splitless Operation (with wool) – Good for analyses of trace samples 2 6.2 92.1 5 N6121021
Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken 2 6.2 92.1 5 N6502004
Quartz Liner for Split Operation – Good for large volume injection samples 4 6.2 92.1 1 N6121001
Glass Liner for Split Operation – Universal liner for general purpose analyses 4 6.2 92.1 1 N6101052
Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems 4 6.2 92.1 5 N6502003
Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean 4 6.2 92.1 5 N6502005
Zero Dilution Glass Outer Liner – Ideal for trace HS work. Use in conjunction with N1011446 2 6.3 90 1 N1011445
Zero Dilution Glass Inner Liner – Ideal for trace HS work. Use in conjunction with N1011445 2 6.3 90 1 N1011446
Programmed Temperature Split/Splitless (PSS) Injector Liners
Quartz Liner for Splitless operation (ships with instrument) – Excellent liner for low volume analyses 1 4 86.2 1 N6121006
NEW! Siltek Deactivated Glass PSS Liner – Used for low volume trace sample analyses 1 4 86.2 5 N6502000
Quartz Liner for Split operation (ships with instrument) – Approved PerkinElmer standard injector liner 2 4 86.2 1 N6121004
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) – Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken 2 4 86.2 5 N6502001
NEW! Siltek Deactivated Glass Liner for Split operation – Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 2 4 86.2 5 N6502002
Zero Dilution Outer Liner –Use in conjunction with N1011446 2.8 4 83 1 N1011447
Zero Dilution Inner Liner –Use in conjunction with N1011447   2 73 1 N1011446
On-column Glass Liner 2.4 4 86.2 1 N6101539
Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 1 N6121008
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 5 N6121009
Packed Column Injector Liners
Drilled Uniliner (hole on top) – Excellent liner for high sample recovery and linearity, recommended for aqueous injections. 4 6.2 92.1 5 N6121022
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. Good for PPC equipped GCs 4 6.2 92.1 5 N6502013
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,active samples, high recovery and linearity 4 6.2 92.1 5 N6502014
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, active samples, high recovery and linearity 4 6.2 92.1 5 N6502015
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue 4 6.2 92.1 5 N6502016
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction 4 6.2 92.1 5 N6502017
Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375
Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003
Colored Injector Liners
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility 2 4 86.2 5 N9306232
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306233
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 1 N9306234
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306235
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample. 4 6.2 92.1 5 N9306236
PSS Splitless deactivated glass liners with deactivated wool 5/pk. 1.25 4 86.2 5 N9306237

工商信息

企业名称

北京博德恒悦科贸有限公司

企业信息已认证

企业类型

信用代码

110108011785230

成立日期

2009-03-26

注册资本

50

经营范围

技术推广、技术开发、技术转让、技术服务、技术咨询;销售自行开发后的产品、润滑油、金属材料、建筑材料、五金交电、化工产品(不含危险化学品及一类易制毒化学品)、机械设备、电子产品、通讯设备、计算机、软件及辅助设备、医疗器械I类、日用品、汽车零配件;仪器仪表维修;技术进出口、代理进出口、货物进出口。(企业依法自主选择经营项目,开展经营活动;依法须经批准的项目,经相关部门批准后依批准的内容开展经营活动;不得从事本市产业政策禁止和限制类项目的经营活动。)

联系我们
Glass Inlet Liners N6502004,N6121001,N6101052,N6502003,N6502005,N1011445,N1011446由北京博德恒悦科贸有限公司为您提供,如您想了解更多关于Glass Inlet Liners N6502004,N6121001,N6101052,N6502003,N6502005,N1011445,N1011446价格、规格、特点、分类选择等信息,欢迎咨询厂家。除供应Glass Inlet Liners N6502004,N6121001,N6101052,N6502003,N6502005,N1011445,N1011446外,还可为您提供ASSY,COL,SPARES,21.2MM,IT、保护卡套色谱柱和附件 、Brownlee色谱柱 N9303974,N9303975,N9303995,N9303996等耗材,公司有专业的客户服务团队,是您值得信赖的合作伙伴,北京博德恒悦科贸客服电话400-860-5168转1683。
推荐产品
供应产品

北京博德恒悦科贸有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 北京博德恒悦科贸有限公司

公司地址: 北京市海淀区安宁庄路26号楼7层713 联系人: 张小姐 邮编: 100085 联系电话: 400-860-5168转1683

仪器信息网APP

展位手机站