仪器种类: 在线监测水质分析仪
看了null的用户又看了
▲能测量pH值、电导率、TDS、氧化还原电位、溶解氧、大气压力及温度。
▲电源模式,能用9V电池或12V电源适配器,能在室内或长时间在户外工作。
▲在测量盐度时(NaCl或KCl),能自动修正电导率对盐度的影响。
▲测量溶解氧时,能自动修正大气压和盐度的影响,从而使测量工作极其简单。
▲能储存950组连续或独立的测试结果,附温度、时间和日期。
测量参数 | pH | ORP |
电导率 盐度 |
温度 | 溶解氧% | 溶解氧 mg/l |
测量范围 | -2.000~16.000 | ±1000 mV |
0~2000 mS/cm 0~200g/l KCl 0~300 g/l NaCl |
-50~199.9 | 0~400 | 0~60.00 |
精度 | 0.002 pH | ±0.1 mV |
0.1%; >20 mS/cm:0.25% |
±0.1 °C* <!--[if !supportLineBreakNewLine]--> <!--[endif]--> |
1% | 0.1 mg/l |
温度补偿 | -5~110 °C | - | -5~70 °C | - | 0~40 °C | 0~40°C |
尺寸(mm) | L=149, W=82, H=22 | |||||
重量 (g) | 230g |
多参数水质检测仪CX-401说明书 • 尺寸小,具备401系列测量pH值、电导率、溶解氧的所有功能。 • 大屏幕LCD显示,读数更清晰。 • 二种供电模式(电池或12V电源适配器),能在室内或长时间在户外工作。 • 可选用充电电池,充电时直接插在测量仪上。 • 测量仪能: - 在测量范围内能准确测量pH值(精度0.002 pH )。 - 能精确测量ORP(精度0.1mV)。 - 能测量纯水或高盐度水。 - 在测量盐度时(NaCl或KCl),能自动修正电导率对盐度的影响。 - 能测量TDS。 - 测量电导率时可改变参考温度。 - 能测量大气压。 - 测量溶解氧时,能自动修正大气压和盐度的影响,从而使测量工作极其简单。 - 温度测量范围宽。 - 数据储存器能记录200组连续或独立的测试结果,附温度、时间和日期。 - 可选配能记录450或950套数据的储存器。 - 能连接电脑或打印机。 • 所有功能操作一致,测量简便。
Dear User! We present you a device distinguished by accuracy according to the technical data and by a high stability of the displayed results. We believe that the measurements will not cause you any trouble and that the meter will operate without any inconvenience. Wide range of additional functions requires careful reading of the manual in other case some of the features may stay unused or using the meter may cause you a troubles. The employing of good-quality electrodes cells and probes and their replacing after a suitable time ensures obtaining of high measuring parameters. We want to call your attention to the fact, that this equipment has a much shorter working life than the meter. Typical symptoms of an improper operation of the electrode are deterioration of final result stability, it’s flowing as well as a higher measuring error. Part of the users has problems, arising from employing electrodes not being preconditioned before the measurement or making the measurements without removing the shielding ring from the liquid junction or taking measurements with a plugged junction. To avoid this situation it is necessary to choose the proper kind of electrode for solutions which are going to be measured ex. special electrodes for the sewage, liquids with deposits, meat cheese etc. Therefore, if you observe improper operation of the device, please take control measurements with another electrode or check the used electrode with another pH-meter. Generally the deterioration of the meter work is caused by the electrode and not by the meter. In case of conductivity measurements it is important to choose the cell with right constant K value for the measuring range. Wrong selection may cause larger error occur, similar situation occurs during measurements with automatic temperature compensation with incorrectly introduced  coefficient. Accuracy of the dissolved oxygen measurements depends on the sensor calibration and regular maintenance which consist in replacing the membranes, electrolyte and cleaning the electrodes. Lack of correct maintaining of the sensor after some time will make measurements impossible. Please turn your attention to the fact that stabile measurement is possible only with simulated or natural measured water flow. The essential feature of our products is their low failure frequency. However if your meter will fail, our firm immediately performs its warranty repair. We wish you a pleasant and trouble-free work with our meter.
最多添加5台