仪器信息网 试剂标物 生化试剂 ELISA试剂盒 人抗兰尼碱受体钙释放通道抗体ELISA Kit
非会员 13
logo
上海希美化学有限公司

认证:工商信息已核实

厂商展位

找不到产品?留下需求帮您找

一键询价
人抗兰尼碱受体钙释放通道抗体ELISA Kit

人抗兰尼碱受体钙释放通道抗体ELISA Kit

价格: 面议

品牌:Cusabio

供货周期: 一周

货号:CSB-E13357h

规格:96T

CAS:CSB-E13357h

 产品名称: 人抗兰尼碱受体钙释放通道抗体ELISA Kit
 
 英文名称: Human anti-ryanodine receptor calcium release channel antibodies ELISA Kit
 
 货号: CSB-E13357h
 
 规格: 96T
 
 种属: Human
 
 待测物名称: anti-ryanodine receptor calcium release channel antibodies
 
 样本类型: serum
 
 反应时间: 1-5h
 
 所需样本体积: 50-100ul
 
 检测波长: 450 nm
 
 用途: For research use only. Not for diagnostic use.
 
 精密度: Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
 
 样本搜集及储存: Serum: Use a serum separator tube (SST) and allow samples to clot for two hours at room temperature or overnight at 4°C before centrifugation for 15 minutes at 1000 ×g. Remove serum and assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
Plasma: Collect plasma using EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 ×g at 2-8°C within 30 minutes of collection. Assay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw cycles.
 
 检测步骤: Bring all reagents and samples to room temperature before use. Centrifuge the sample again after thawing before the assay. It is recommended that all samples and standards be assayed in duplicate.
1. Prepare all reagents, working standards, and samples as directed in the previous sections.
2. Refer to the Assay Layout Sheet to determine the number of wells to be used and put any remaining wells and the desiccant back into the pouch and seal the ziploc, store unused wells at 4°C.
3. Add 100μl of standard and sample per well. Cover with the adhesive strip provided. Incubate for 2 hours at 37°C. A plate layout is provided to record standards and samples assayed.
4. Remove the liquid of each well, don't wash.
5. Add 100μl of Biotin-antibody (1x) to each well. Cover with a new adhesive strip. Incubate for 1 hour at 37°C. (Biotin-antibody (1x) may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.)
6. Aspirate each well and wash, repeating the process two times for a total of three washes. Wash by filling each well with Wash Buffer (200μl) using a squirt bottle, multi-channel pipette, manifold dispenser, or autowasher, and let it stand for 2 minutes, complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining wash Buffer by aspirating ordecanting. Invert the plate and blot it against clean paper towels.
7. Add 100μl of HRP-avidin (1x) to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
8. Repeat the aspiration/wash process for five times as in step 6.
9. Add 90μl of TMB Substrate to each well. Incubate for 15-30 minutes at 37°C. Protect from light.
10. Add 50μl of Stop Solution to each well, gently tap the plate to ensure thorough mixing.
11. Determine the optical density of each well within 5 minutes, using a microplate reader set to 450 nm. If wavelength correction is available, set to 540 nm or 570 nm. Subtract readings at 540 nm or 570 nm from the readings at 450 nm. This subtraction will correct for optical imperfections in the plate. Readings made directly at 450 nm without correction may be higher and less accurate.
 
 结果计算: Using the professional soft "Curve Expert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard and sample and subtract the average zero standard optical density.
Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the anti-ryanodine receptor calcium release channel antibodies concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data.
If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.  




生化试剂 人抗兰尼碱受体钙释放通道抗体ELISA Kit由上海希美化学有限公司为您提供,如想了解更多关于ELISA试剂盒 人抗兰尼碱受体钙释放通道抗体ELISA Kit的报价、规格、厂家等信息,欢迎来电或留言咨询。除供应人抗兰尼碱受体钙释放通道抗体ELISA Kit外,上海希美化学有限公司还可为您提供:
推荐专场
同类试剂
该厂商试剂
相关厂商
手机版: