Pinnacle’s FAST SCAN CYCLIC VOLTAMMETRY (FSCV) SYSTEM is specifically designed to simplify the measurement of catecholamines (i.e., dopamine, norepinephrine, and serotonin). Pinnacle offers turn-key systems for both mice and rats. Both the wireless rat system and the tethered mouse system use carbon fiber sensors to enable short-term measurement in the brains of freely moving animals.
HOW IT WORKS
Biogenic amine levels are detected by rapidly cycling a voltage across an implanted carbon fiber sensor and measuring the resultant current. Our systems can measure spontaneous sub-second neurotransmitter release events while conducting detailed behavioral studies. Both the wireless and tethered systems sweep from 250 to 400 V/s in a user-selectable range spanning -1.1 to +1.3 V. All systems have built-in support for controlling an external stimulus.
l Voltage Span: -1.1 V to +1.3 V
l Range: 250 – 400 V/s
l Sweeps/second: 5 - 10
l Points/sweep: 1000
Dopamine (blue), serotonin (green), and norepinephrine (pink) have specific voltammogram profiles when detected by FSCV.
The TETHERED FAST SCAN CYCLIC VOLTAMMETRY (FSCV) SYSTEM allows researchers to harness the powerful genetics of the mouse model to address underlying mechanisms of biogenic neurotransmitter release and function. A headmounted FSCV board sends signals through a low-torque commutator to an interface box that streams data to the host PC. The system comes with Pinnacle’s FREE 8500 software.
1. The FSCV interface box provides access to stimulus lines and transmits data to PAL-8500 software.
2. A low-torque commutator, which is mounted above the cage, allows for unencumbered freedom of movement.
3. Signals are amplified and filtered at the head of the animal using our headstage, which ensures the delivery of clean, artifact-free data.
4. Stereotaxically placed guide cannulas allow easy insertion of carbon fiber sensors. Headmounts are affixed to the skull with dental acrylic and act as a connection port for the headstage.
CARBON FIBER
Pinnacle’s FSCV system uses CARBON FIBER SENSORS (CFSs) to measure the presence of dopamine and other catecholamines in the brains of freely moving animals. Our sensor is a 34 µm diameter carbon fiber housed in a silica sheath that extends 0.5 mm beyond the end of the silica. All Pinnacle CFSs require an Ag/AgCl reference electrode.
Our sensor is a 34 um diameter carbon fiber housed in a silica sheath that extends 0.5 mm beyond the end of the silica.
Carbon fiber sensors are ordered by cannula type and whether the researcher needs to remove them from the cannula for post-calibration. CFS-F sensors are fixed in the cannula and cannot be removed for post-calibration。
The FSCV system includes Pinnacle’s FREE PAL-8500 software, which supports traditional, short recording paradigms (recordings of two minutes or less) as well as longer-term recordings that use an extended continuous mode. Furthermore, the suite supports integrated, synchronized video recording, which allows monitoring of animal behavior simultaneously with biogenic amine release.
Additional features of this software include:
• Background Subtraction
• 3D Visualization
• User-Selectable Filters
• Heat Maps
• Animated Voltammograms
• Export to Third-Party Packages
请关注玉研仪器的更多相关产品。
如对产品细节和价格感兴趣,敬请来电咨询!
玉研仪器其它电化学检测系统,扫描循环伏安法(FSCV)的工作原理介绍
其它电化学检测系统,扫描循环伏安法(FSCV)的使用方法?
玉研仪器电化学检测系统,扫描循环伏安法(FSCV)多少钱一台?
其它电化学检测系统,扫描循环伏安法(FSCV)可以检测什么?
其它电化学检测系统,扫描循环伏安法(FSCV)使用的注意事项?
玉研仪器电化学检测系统,扫描循环伏安法(FSCV)的说明书有吗?
玉研仪器其它电化学检测系统,扫描循环伏安法(FSCV)的操作规程有吗?
玉研仪器其它电化学检测系统,扫描循环伏安法(FSCV)报价含票含运吗?
玉研仪器电化学检测系统,扫描循环伏安法(FSCV)有现货吗?
企业名称
上海玉研科学仪器有限公司
企业信息已认证
企业类型
有限责任公司(自然人投资或控股)
信用代码
9131011655875002XG
成立日期
2010-07-06
注册资本
人民币100.0000万元整
经营范围
科学仪器仪表;化工原料及产品、化学试剂(除危险化学品.监控化学品、烟花爆竹、民用爆炸物品、易制毒化学品);计算机、软件及辅助设备;装璃制品,金属材料、塑料制品、有机玻璃销售,从事计算机、电子科技领城内技术开发、技术咨询、技术服务;从事仪器仪表科技专业领城域内技术开发;技术转让、技术咨询、技术服务,从事货物进出口及技术进出口业务。(依法须经批准的项目,经相关部门批准后方可开展经营活动]
上海玉研科学仪器有限公司
公司地址
闵行区兴梅路485号中环科技园301室
客服电话