您好,欢迎访问仪器信息网
注册
上海菁仪化工材料有限公司

关注

已关注

铜牌11年 铜牌

已认证

粉丝量 0

400-860-5168转3311

仪器信息网认证电话,请放心拨打

当前位置: 菁仪化工 > 其它色谱仪 > CTC自动进样器/固相微萃取头
  • CTC自动进样器/固相微萃取头
  • CTC自动进样器/固相微萃取头

CTC自动进样器/固相微萃取头

品牌:
产地: 美国
型号: 57298-U
报价: ¥2940
产品介绍

气体样品自动进样、静态顶空自动进样、大体积顶空进样、自动固相微萃取、自动液-液萃取、在线样品衍生、热解析和直接热解析。 支持以下气相: Agilent5890/6890/6850 Thermo Trace2000/GC8000top Varian GC/3400/3600/3800/3900 Shimadzu GC14/17/2010 PE Autosystem XL/Clarus 500 支持以下色谱工作站: Agilent Chemstation DataApex Clarity Dionex Chromeleon EZChrom E lite/Ezstart Justice Software Shromperfect Leco Chrom TOF Shimadzu GC/GCMSsolution Shimadzu Class VP Therom ChromQuest Therom Xcalibur Varian Star/Galaxie Waters Masslynx XYZ进样方式 模块化设计 大体积进样技术 无样品定量环 可按需要制 高效率的样品进样 无传输管道 各模块更换便捷 与主流GC/GC-MS 无切换阀 系统无缝兼容

Solid phase microextraction, or SPME, is a sample preparation technique used both in the laboratory and on-site. Developed in the early 1990s at the University of Waterloo by Dr. Pawliszyn's group, it is a simple and inexpensive technique where the use of solvents is not necessary.

SPME can be thought of as a very short gas chromatography column turned inside out. SPME involves the use of a fiber coated with an extracting phase, that can be a liquid (polymer) or a solid (sorbent), which extracts different kinds of analytes (including both volatile and non-volatile) from different kinds of media, that can be in liquid or gas phase. The quantity of analyte extracted by the fiber is proportional to its concentration in the sample so long as equilibrium is reached or, in case of short time pre-equilibrium, with help of convection or agitation. After extraction, the SPME fiber is transferred to the injection port of separating instruments, such as a Gas Chromatograph, where desorption of the analyte takes place and analysis is carried out.

The attraction of SPME is that the extraction is fast and simple and can be done without solvents, and detection limits can reach parts per trillion (ppt) levels for certain compounds. SPME also has great potential for field applications; on-site sampling can be done even by nonscientists without the need to have a GC-MS at each location. When properly stored, samples can be analyzed days later in the laboratory without significant loss of volatiles.

 


 

Solid phase microextraction is a fast, solvent less alternative to conventional sample extraction techniques. In SPME, analytes establish equilibria among the sample matrix, the headspace above the sample, and a polymer-coated fused fiber, then are desorbed from the fiber to a chromatography column. Because analytes are concentrated on the fiber, and are rapidly delivered to the column, minimum detection limits are improved and resolution is maintained. SPME is compatible with analyte separation/detection by gas chromatography or HPLC, and provides linear results for wide concentrations of analytes.

 


 

SPME is an equilibrium process based upon Fick’s 1st law of diffusion

 


 

SPME is a technique where the sample is incubated or agitated to equilibrate the headspace. A SPME fiber is then introduced to the headspace for a predetermined period of time. The SPME fiber is then transferred to a hot GC injection port. Analytes that were adsorbed to the fiber from the sample headspace are desorbed directly in the GC inlet. SPME fibers are a distributed by Supleco and are available in a wide variety of polarities. By matching fiber polarity with target analyte characteristics, the analysis can be optimized for improved sensitivity and performance.

 


 

SPME extraction for heated and agitated samples
For use with standard SUPELCO SPME fibers
Septumless Injector and SPME liners recommended

 

SPME offers some important advantages:

  • Single Step Extraction - reduces sample preparation time by 70%

  • Versatility - various selectivities available, adapts to any GC or HPLC system, can be automated

  • Efficient & Economical - little/no use of solvents, quantitative method, allows more than 50 extractions per fiber on average

Comparison of SPME to SPE

SPE exhaustively extracts all of the analytes, but they are diluted during elution 1mL of sample containing 1μg/mL of analyte passed through tube, eluted with 1mL of solvent = 1μg/mL X 1μl injection = 1ng (Concentrating to 100μl or injecting 10μl = 10ng on column

SPME partially extracts analytes but desorbs the entire amount 1mL sample containing 1μg/mL of analyte extracted with fiber. 1% goes on fiber. 0.01 x 1μg = 10ng desorbed on column 
SPME Twin PAL

 

Dual SPME is now possible


LEAP now has the ability increase SPME throughput with Chronos Scheduling software 
This is performed with a Dual Rail SPME extraction and injection to a GC. Synchronization with the GC can be integrated with Chronos or with contact closure. To achieve optimal throughput, the second arm will be prepping with SPME on separate tray while the previous GC run is in progress. This allows "Prep Ahead" functionality never before capable. 


工商信息

企业名称

上海菁仪化工材料有限公司

企业信息已认证

企业类型

信用代码

310116003078121

成立日期

2014-04-25

注册资本

50

经营范围

化工原料及产品(除危险化学品,监控化学品、烟花爆竹、民用爆炸物品、易制毒化学品),建筑材料,服装服饰及辅料,工艺礼品,鞋帽,日用百货,办公文化用品,体育用品,健身器材,化妆品,皮革制品,电子产品,仪器仪表,家用电器销售,从事“化工科技、电子科技”领域内的技术开发、技术咨询、技术服务。【依法须经批准的项目,经相关部门批准后方可开展经营活动】

联系我们
上海菁仪化工材料有限公司为您提供CTC自动进样器/固相微萃取头57298-U,null57298-U产地为美国,属于其它色谱仪,除了CTC自动进样器/固相微萃取头的参数、价格、型号、原理等信息外,还可为您提供更多其它色谱仪,菁仪化工客服电话400-860-5168转3311,售前、售后均可联系。
推荐产品
供应产品

上海菁仪化工材料有限公司

查看电话

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 上海菁仪化工材料有限公司

公司地址: 金山区环东一路88号 联系人: 赵先生 邮编: 201501 联系电话: 400-860-5168转3311

仪器信息网APP

展位手机站