您好,欢迎访问仪器信息网
注册
常州金坛精达仪器制造有限公司

关注

已关注

已认证

粉丝量 0

当前位置: 常州金坛精达仪器 > 解决方案 > 石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器水质一览表

石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器水质一览表

2009/11/03 08:49

阅读:662

分享:
应用领域:
生物产业
发布时间:
2009/11/03
检测样品:
检测项目:
浏览次数:
662
下载次数:
参考标准:
百分之九十

方案摘要:

石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器水质一览表: 附表:金属离子含量分析结果表 项目 ca Mg Mn Fe Cu Zn Al Co Ni Cr Cd Pb 双重水(ug/L) 0.45 0.2 0.15 8.3 0.59 4.22 0.2 0.2 0.15 0.25 0.04 0.15 一:石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器的按装方式: 仪器开箱后将冷凝管取出来消毒后插入横式烧瓶的磨口上。蒸馏水的出口应面向前面。使水位器上管口的橡皮管另一端套在冷凝管上出水口上,前一端短橡皮管套在水位器出水口部。但应注意管路畅通。并不得高于出水口处的水平线。以免影响蒸馏瓶内的水位,现用橡皮管套在冷凝下部进水口,并与水源相连,自来水即主冷却管,水位器到横式烧瓶内,具水位高度由水位器控制,冷却水的路线是自来法,进入二次冷却管的下进水口,经由上出水口流入一次冷却管的下进水口,由上出水口流入水位器,在初次蒸馏时,接通电源,一次蒸馏先行开始,蒸馏之水流入二次蒸馏瓶中,待水位达到应有高度后(约1小时)插上二次蒸馏电源插头,二次蒸馏开始蒸馏。出来的蒸馏水纯度有进一步提高,每小时出水量为2000ml—2500ml左右. 二、石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器仪器的清洗: 在蒸馏一段时间后,水垢就聚在横式烧瓶内及加热管表面上,这时必须要进行清洗,清洗的次数主要视自来水的硬度和使用时间而定,如仪器长时间不进行清洗,要影响蒸馏效果,严重的要损坏加热管,并且清洗时间要延长。 三、石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器的清洗步骤; 1.切断电源,关上自来水。 2.加入浓盐酸100ml到横式烧瓶内,与瓶内的水释盐酸,如积垢较多盐酸可多加一些,数分钟后由水位器放出,最后用自来水冲洗数次,为了清除微量盐酸,可将烧瓶前后摇动,使不易清洗的死角冲洗为上。 3.再次蒸馏时,开始10分钟内所蒸馏的水,舍去不用。 四、石英自动双重纯水蒸馏器\石英双重纯水蒸馏器\自动双重高纯水蒸馏器的注意事项: 采用二次蒸馏装置必须注意水位的控制,因冷却水的水不再经过水位器再直接排放掉,烧瓶水位只能依赖烧瓶及进行控制水位器来进行控制,在任何情况下,烧瓶内水不允许放完, 因此烧瓶容积不宜小于20升(即4小时以上的蒸馏量),不然,在蒸馏时应经常加水,以免断水而烧坏仪器。

下载本篇解决方案:

资料文件名:
资料大小
下载
石英亚沸高纯水蒸馏器.jpg
41KB
相关方案

NanoBrook产品应用-12-ZetaPALS

文献名: Structural, morphological and optical properties of Bi NPs obtained by laser ablation and their selective detection of L-cysteine 作者: Ramon Gabriel Teixeira Rosaa, Celso de Araujo Duartea , Wido Herwig Schreinera, Ney Pereira Mattoso Filhoa, Arandi Ginane Bezerra Jr.b, Andersson Barisonc, Fernanda Maria Marins Ocamposc a Departamento de Física, Universidade Federal do Paraná Centro Politécnico, CP 19044, 81531-990 Curitiba (PR), Brazil b Departamento Acadêmico de Física, Universidade Tecnológica Federal do Paraná, 80230-901 Curitiba (PR), Brazil c Departamento de Química, Universidade Federal do Paraná Centro Politécnico, CP 19081, 81531-990 Curitiba (PR), Brazil 摘要:In the present work we show the results of the investigation of the properties of bismuth nanoparticles (NPs) obtained by the laser ablation in water. The samples were characterized by various techniques: UV/vis spectroscopy, dynamic light scattering, transmission electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, nuclear magnetic resonance and zeta potential. The NPs were metallic and surface oxidated, exhibiting absorption peak at 257 nm due to the surface plasmon resonance. The interaction between the NPs and various amino acids was studied and revealed a selective sensibility to cysteine on a range of concentration from 80 to 720 μM, which we attribute to a dimerization of cysteine to cystine probably complexed to the nanoparticle surface by electrostatic interactions, leading to the modification of the NP absorption spectrum. 关键词:Bismuth; Nanoparticles; Laser ablation; Cysteine

2015/04/16

植物油中9种抗氧化剂的测定GB5009.32-2016

抗氧化剂是指能防止或延缓食品氧化,提高食品的稳定性和延长贮存期的食品添加剂。GB5009.32-2016《食品安全国家标准 食品中9种抗氧化剂的测定》中采用GPC和C18小柱对食品中9种抗氧化剂进行前处理,该方法回收率低,测试结果不稳定。安谱实验优化了实验方法,用CNW Poly-Sery PSD SPE小柱进行前处理,克服了国标方法的缺点,方法简单,9种抗氧化剂的回收率均在90%以上。

食品/农产品

2019/07/31

称量仪器的校准

当称量仪器用于与质量控制相关的测量时,校准是必须定期执行的关键操作之一。国际上有许多标准规范都有这方面的要求,例如ISO9001、GMP法规以及与食品安全相关的一些标准。然而关于校准的定义、实施和校准的具体操作在全球范围内并没有一个完全统一的标准。在此,我们首先需要了解一下什么是校准,以及与调整和检定的区别。

其他

2022/04/23

血液中乙醇含量的测定

AP500全自动样品处理工作站的设计从如何提高样品前处理效率的角度考虑,将样品处理的全过程自动化。

公安/司法

2023/02/08

常州金坛精达仪器制造有限公司

沟通底价

提交后,商家将派代表为您专人服务

获取验证码

{{maxedution}}s后重新发送

获取多家报价,选型效率提升30%
提交留言
点击提交代表您同意 《用户服务协议》 《隐私政策》 且同意关注厂商展位
联系方式:

公司名称: 常州金坛精达仪器制造有限公司

公司地址: 江苏省金坛市经济开发区 联系人: 邮编: 213200

仪器信息网APP

展位手机站