Nu Instruments公司是世界著名的等离子体多接收质谱仪公司。公司从1994年设计出的第一台等离子体多接收质谱仪到现在一直延续,并积累了丰富的经验,仪器稳定,实用,可靠,故障率低。Nu plasma是新一代的仪器,增加了多项新颖独特的技术。在地球化学和放射性同位素化学有广泛的应用。具有高灵敏度,高分辨率,高精度,高准确度的特点。为用户提供了无以伦比的分析利器,在全世界拥有众多的用户群体和良好的用户评价。公司生产的Nu 1700更是代表了多接收电感耦合等离子体质谱仪器的终极技术。
1.仪器标准分辨率(10%峰谷)400, 高分辨〉3000
2.灵敏度:U>2.5 x109 cps/ppm
3.精度:Nd143/144 <20ppm, Hf 176/177<20ppm,Pb 206/207 <20ppm, U 235/238< 200ppm
4.12个法拉第杯,3个离子计数器
1.双聚焦质谱仪,变焦离子镜和没有移动部件的多接收器,测量之间也能保持瞬间峰的同时变化,高性能陶瓷法拉第桶
2.高性能层状磁场,所有的真空泵和传感器全部接地保护,高离子化率的ICP离子源,高性能的电子系统具有优秀的设计和制造,全面监控仪器所有的参数
3.软件具有误操作保护,Windows 9x, 2000下的现代数据控制软件,软件源代码公开
4.可选的减速离子镜过滤器,提高丰度灵敏度
5.可选的三个不移动离子计数器采用的是不连续打拿极电子倍增器,维修花费少,兼容其他附件,包括激光烧蚀系统和其他样品准备设备
更多
更多
Hafnium Analysis
The analysis of hafnium is shown in the table below. The data was measured on the Nu Plasma 1700 under both low and medium (~2400RP) conditions.
74KB
2003/07/15
Neodymium Analysis
The analysis of a neodymium solution (factory standard) is shown in the table below. The data was measured on the Nu Plasma 1700 under low and medium (~2300RP) resolution conditions
85KB
2003/07/15
Lithium Analysis
We show below some preliminary results obtained using the Nu Plasma 1700 with an ICP standard Lithium solution. The sample introduction system consisted of a conventional double pass spray chamber, and no attempt was made to optimise sensitivity for this experiment. The solution used was 1.5ppm, and gave a signal of 17.5volts.
75KB
2003/07/15
Chromium Analysis
The mass spectrum of Chromium is shown below. The data was measured on the Nu Plasma 1700 at medium (~2600RP) conditions, and illustrates some of the problems which are to be expected with measurements of this element.
139KB
2003/07/15
Abundance Sensitivity
The abundance sensitivity of the Nu Plasma 1700 is shown and is measured by determining the tail from the 238U at mass 237. The scans show the 238U measured on the L2 Faraday with the 236U and 237 mass range being measured by the IC0 ion counting multiplier.
231KB
2003/07/15
U-Pb Analysis
For in-situ laser ablation and low level solution analysis of U-Pb measurements, Nu Instruments have developed an optional ‘plug-in’ collector block which allows 204Pb, 206Pb, and 207Pb to be simultaneously measured on ion-counting multipliers whilst measuring 238U and 238U in Faraday collectors (Figure 1). For mass bias corrections simultanoeus measurement of 203Tl and 205Tl can also be made. Using this method, lead blanks and 204Hg isobaric interference corrections can be made by performing an on-peak blank measurement immediately before the sample is introduced into the plasma. This new U-Pb block does not reduce the degree of flexibility for other type of analysis such as hafnium, neodymium etc as only the locations of the ion-counting multiplier slots have been relocated.
176KB
2005/01/25