举报
快速选型
Dionex IonPac AS20 阴离子交换柱 063148
基本信息:
价格:面议
供货周期:现货
品牌:戴安
货号:

63148

 
参数规格:
具体参数见产品详情
                     
  • 产品介绍
  • 全部规格
  •      
产品介绍

Dionex IonPac AS20 阴离子交换柱

 

 

饮用水中高氯酸盐的简化,地表水和地下水的微量分析,矩阵使用Thermo Scientific? Dionex? IonPac? AS20毛细管,分析保护柱。本专栏的容量和选择性确保高氯酸盐可以量化的低μg/L采用抑制电导检测的浓度,即使在浓度很高的氯化物,碳酸盐和硫酸盐的存在。本栏是美国环保局规定的314.1用于样品预浓缩后饮用水中痕量高氯酸的测定(验证性方法)。



Dionex IonPac AS20 阴离子交换柱

订货信息:

分析柱
IonPac AS20 Analytical Column (2 x 250 mm)063065
IonPac AS20 Analytical Column (4 x 250 mm)063148
IonPac AS20 Capillary Column (0.4 x 250 mm)075399
保护柱
IonPac AG20 Guard Column (2 x 50 mm)063066
IonPac AG20 Guard Column (4 x 50 mm)063154
IonPac AG20 Capillary Guard Column (0.4 x 50 mm)075400

 


For Determination of Trace Perchlorate Using Suppressed Conductivity Detection

The IonPac? AS20 hydroxide-selective anion-exchange column is specifically designed for determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low μg/L concentrations using suppressed conductivity detection, even in the presence of very high concentrations of chloride, carbonate, and sulfate. The new IonPac AS20 Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

  • Recommended for US EPA Method 314.1 (Confirmatory Method)

  • High capacity: 310 μeq per column. (4 × 250 mm)

  • Use the Cryptand C1 Concentrator Column for sample preconcentration with the analytical column

  • Simplified Reagent-Free IC operation provided by the Eluent Generator

  • ASRS 300 or ACES 300 provides RFIC operation with low background and enhanced analyte sensitivity

  • Column selectivity is optimized for 30 °C operating temperature

  • Compatible with organic solvents

The IonPac AS20 is the specified column in US EPA Method 314.1 (Confirmatory Method). The Cryptand C1 Concentrator Column is the specified concentrator column for sample preconcentration in that method.

Use the IonPac AS20 column with an RFIC? system for optimum detection limits. Use the Anion Self-Regenerating Suppressor (ASRS? 300) or the Anion Capillary Electrolytic Suppressor (ACES 300) with the AS20 column for eluent suppression.

 

IonPac AS20 Anion-Exchange Column   Specifications
Maximum Operating Pressure:4000 psi (standard and microbore) 5000 psi (capillary)
Mobile Phase Compatibility:pH 0–14; 0–100% HPLC solvents
Ion Exchange Group:Functional Group: Alkanol quaternary ammonium ion
Column Construction:PEEK with 10–32 threaded ferrule style end fittings.
All components are nonmetallic.
Functional Group Characteristics:Ultralow Hydrophobicity
Dimensions:
IonPac AS20 Capillary Column:
0.4 ×250 mm 
IonPac AG20 Capillary Guard Column: 
0.4 × 50 mm 
IonPac AS20 Analytical Column:
2 × 250 mm
IonPac AG20 Guard Column:
2 × 50 mm
IonPac AS20 Analytical Column:
4 × 250 mm
IonPac AG20 Guard Column:
4 × 50 mm

 

Capacity:

3.1 μeq (0.4 × 250 mm capillary column)
77.5 μeq (2 × 250 mm analytical column)
310 μeq (4 × 250 mm analytical column)
0.06 μeq*(0.4 × 50 mm capillary guard column)
1.5 μeq* (2 × 50 mm guard column)
6 μeq* (4 × 50 mm guard column)
*Guards are packed with a low-capacity microporous resin.

Substrate Characteristics:Bead Diameter and Pore Size:
7.5 μm (2 × 250, 4 × 250 and 0.4 × 250 mm);
super macroporous resin (2000 ?)
11 μm (2 × 50, 4 × 50 and 0.4 × 50 mm);
microporous resin (<1 ?)
Crosslinking (%DVB): 55%

Determination of trace-level perchlorate in drinking water using the AS20 column following concentration on a Cryptand C1 Concentrator column.

 

System flow path for trace-level perchlorate in drinking water.

 

Separation of anions using an IonPac AS20 capillary column.

Determination of trace concentrations of bromate using the IonPac AS20 with two-dimensional ion chromatography.

Gradient separation of a variety of environmental anions using the IonPac AS20 column.

 

Comparison of the IonPac AS16 and AS20 columns for separation of common anions, hydrophobic anions and 4-chlorobenzene sulfonate.

Product Data Sheets
IonPac AS20 Anion-Exchange Column Data Sheet
IonPac AS20 Analytical Column Manual
Application Notes
AN 1024: Improved Determination of Trace Perchlorate in Drinking Water Using 2D-IC
AN 279: Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples
AN 258: Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production
AN 178: Improved Determination of Trace Concentrations of Perchlorate in Drinking Water Using Preconcentration with Two-Dimensional Ion Chromatography and Suppressed Conductivity Detection
AN 176: Determining Sub-ppb Perchlorate in Drinking Water Using Preconcentration/Matrix Elimination IC with Suppressed Conductivity Detection by U.S. EPA Method 314.1